heat pump cool only
Hi:
How do I wiring a heat pump to cool only with 2 low volts cable from the air handler
Last edited by Pricer Air; 08-14-2022 at 04:52 AM.
Reason: mispelling
-
-
Originally Posted by
Pricer Air
Hi:
How do I wiring a heat pump to cool only with 2 low volts cable from the air handler
You’d listed as a contractor?
-
What Brand is the Outdoor Unit ?
Most manufacturers energize the "Reversing Valve" on Cooling mode (Rheem & Ruud , maybe Ameristar , energize in "Heat") If the unit has an "O" terminal on the Board it means the Rev Valve energizes in Cooling , so it must get power when AC is needed , and if the unit has "B" means the Rev Valve energizes in Heating which means it wont need power at all, because its already in Cooling mode
(Although sometimes B can be "common" on older units, so follow your wires to see where they go)
So if your unit energizes in cooling "O" .... you just wire "O" to come on with "Y"
We cannot give you any more information about wiring ... that is all you get
Tell your Cat I said "Psst Psst Psst"
It seems like everywhere I go the AC is broken
-
Originally Posted by
pecmsg
You’d listed as a contractor?
Dude ... I know 2 contractors who are TERRIBLE when it comes to wiring
Granted both are Foreigners
1 called me last week "how do I bypass the door switch"
Tell your Cat I said "Psst Psst Psst"
It seems like everywhere I go the AC is broken
-
Post Likes - 2 Likes, 0 Dislikes
-
Originally Posted by
Snapperhead
Dude ... I know 2 contractors who are TERRIBLE when it comes to wiring
Granted both are Foreigners
Maybe is resi comfort cooling adopted common wire colors it would be better.
Did some amistar units (supplied by building owner) and they used purple wire for the w signal. Like really. Purple….
And they used black wire to the common term where I see most people use blue.
Sent from my iPhone using Tapatalk
-
Post Likes - 1 Likes, 0 Dislikes
-
Originally Posted by
jbhenergy
Maybe is resi comfort cooling adopted common wire colors it would be better.
Did some amistar units (supplied by building owner) and they used purple wire for the w signal. Like really. Purple….
And they used black wire to the common term where I see most people use blue.
Sent from my iPhone using Tapatalk
I say make em all black wires and do away with color coding, would force people do pay closer attention to what’s going on. 😂
-
Post Likes - 3 Likes, 0 Dislikes
-
Originally Posted by
Hurst11
I say make em all black wires and do away with color coding, would force people do pay closer attention to what’s going on. 😂
and how to use a Meter!
-
Post Likes - 1 Likes, 0 Dislikes
-
Originally Posted by
Hurst11
I say make em all black wires and do away with color coding, would force people do pay closer attention to what’s going on.
White with tiny letters like Carrier used to use.
"Is this before or after you fired the parts cannon at it?" - senior tech
I'm tired of these mediocre "semi flammable" refrigerants. If we're going to do it let's do it right.
Unless we change direction we are likely to end up where we are going.
"It's not new, it's better than new!" Maru.
-
Seen Trane rtus with all black wires and tiny white numbers. Not all the bad really. Find your part in the diagram and then look and see you need wire 423 and 424….
Sent from my iPhone using Tapatalk