Search:

Type: Posts; User: R600a

Page 1 of 9 1 2 3 4

Search: Search took 0.04 seconds.

  1. Thread: Neglected roof

    by R600a
    Replies
    7
    Views
    212

    You mean you dont just put it on your shoulder...

    You mean you dont just put it on your shoulder and walk down the ladder? [emoji23]

    Sent in a state of increasing entropy using Tapatalk:)
  2. Thread: Neglected roof

    by R600a
    Replies
    7
    Views
    212

    Never mind I figured it out the thing I thought...

    Never mind I figured it out the thing I thought was refrigeration unit is the compressor.

    Sent in a state of increasing entropy using Tapatalk:)
  3. Thread: Neglected roof

    by R600a
    Replies
    7
    Views
    212

    Elementary question but what is a discus? Is it...

    Elementary question but what is a discus? Is it the compressor beside the Refrigeration condensing unit? And what makes it special?

    Sent in a state of increasing entropy using Tapatalk:)
  4. Replies
    8
    Views
    203

    Sent in a state of increasing entropy using...

    Sent in a state of increasing entropy using Tapatalk:)
  5. Replies
    5
    Views
    164

    I am happy to help. Sometimes we get stuck on...

    I am happy to help. Sometimes we get stuck on what we think is wrong.

    I tell my customers to only use the dampers for balancing not to try and save energy.

    Definitely check airflow if you didnt...
  6. Replies
    8
    Views
    203

    What does the chart say for 9 flashes? Sent in...

    What does the chart say for 9 flashes?

    Sent in a state of increasing entropy using Tapatalk:)
  7. Replies
    5
    Views
    164

    That last one actually happened to us. Trane gave...

    That last one actually happened to us. Trane gave us the ac only coil for a heatpump. Took us a bit to figure that one out.

    Sent in a state of increasing entropy using Tapatalk:)
  8. Replies
    5
    Views
    164

    Checklist: Air filter Are many dampers closed?...

    Checklist:
    Air filter
    Are many dampers closed?
    Blower wheel
    Static pressure compare to fan chart and blower setting.
    Do the Model# Serial# of the indoor unit match the acceptable matches in the...
  9. Replies
    86
    Views
    2,131

    That is interesting. We are much more vague than...

    That is interesting. We are much more vague than that on our invoices. I like your analogy.

    Sent in a state of increasing entropy using Tapatalk:)
  10. Replies
    86
    Views
    2,131

    Wow i am lost. I am glad we deal direct with our...

    Wow i am lost. I am glad we deal direct with our customers. I would put that as thermostat instalation. We are alotted 1 hour in our normal charge and can raise that if need be. It only takes 10...
  11. Replies
    86
    Views
    2,131

    I am not shure what you mean by rates. Sent in...

    I am not shure what you mean by rates.

    Sent in a state of increasing entropy using Tapatalk:)
  12. Replies
    86
    Views
    2,131

    I would. I always have an iron and a roll of...

    I would. I always have an iron and a roll of solder handy. Not to mention like 8 sizes of heat shrink tube.

    Sent in a state of increasing entropy using Tapatalk:)
  13. Replies
    86
    Views
    2,131

    Twist neatly and pull out the soldering iron and...

    Twist neatly and pull out the soldering iron and some lead solder.

    Sent in a state of increasing entropy using Tapatalk:)
  14. Replies
    86
    Views
    2,131

    Oh darn. Looks like they got their grimy hands in...

    Oh darn. Looks like they got their grimy hands in all of it. [emoji23]

    Sent in a state of increasing entropy using Tapatalk:)
  15. I have also had an excellent experience with...

    I have also had an excellent experience with Honeywell and resideo tech support I've called both before and after the split and they've always been amazing. I hit resideo with some pretty deep...
  16. Replies
    86
    Views
    2,131

    Last i checked the IAQ is still honeywell. At...

    Last i checked the IAQ is still honeywell. At least the tech support for the IAQ is Honeywell.

    Sent in a state of increasing entropy using Tapatalk:)
  17. Replies
    86
    Views
    2,131

    It is a sad day. My favorite controls brand has...

    It is a sad day. My favorite controls brand has been corrupted. [emoji23]
    I may have to switch to the iaq line since it is still unadulterated honeywell.

    Sent in a state of increasing entropy...
  18. Replies
    19
    Views
    711

    I have a solenoid from an old carier 60% gas...

    I have a solenoid from an old carier 60% gas valve i think it was. I just screw the thermocouple into it and if it holds then i call the valve bad.

    Sent in a state of increasing entropy using...
  19. Replies
    10
    Views
    322

    I never have liked them because they require me...

    I never have liked them because they require me to download a manual because i dont have it memorized. [emoji23]
    I have always used the t series honeywell or Trane basic thermostats. I also like the...
  20. Thread: HEATPIPS in FAHU

    by R600a
    Replies
    9
    Views
    533

    It seems like a desuperheater type setup would be...

    It seems like a desuperheater type setup would be more efficient than the heat pipe anyway because it could help lower head pressure.

    Sent in a state of increasing entropy using Tapatalk:)
  21. Thread: HEATPIPS in FAHU

    by R600a
    Replies
    9
    Views
    533

    Keep us posted. If you do remove it i would...

    Keep us posted.
    If you do remove it i would love to see before and after refrigerant saturation temps and dew points of supply and return air.

    Sent in a state of increasing entropy using...
  22. Replies
    14
    Views
    902

    I tend to think that most variable speed units...

    I tend to think that most variable speed units are not so expensive just because of the inverter technology because minisplits are available for $400 - $800 up to 2 tons and they are decently...
  23. Replies
    13
    Views
    625

    The inside looks fine in your pictures I think...

    The inside looks fine in your pictures I think that's just corrosion from the salt. I would have serviced it but then again in my market most everything looks worse than that.

    Sent in a state of...
  24. Replies
    14
    Views
    902

    The other thing is that you can have one...

    The other thing is that you can have one controller that runs any common voltage and frequency.

    Sent in a state of increasing entropy using Tapatalk:)
  25. Replies
    14
    Views
    902

    I think you would be better off with a good...

    I think you would be better off with a good inverter drive reciprocating compressor. It should last longer and if the inverter goes bad you can replace it. Besides that your electrical efficiency...
  26. Replies
    14
    Views
    902

    My understanding is that if you want to build a...

    My understanding is that if you want to build a scroll you have to buy the compressor plates from Copeland because they are the only one that knows how to machine them properly.

    Sent in a state of...
  27. Thread: duct design ?

    by R600a
    Replies
    6
    Views
    254

    Yes but if you have multiple you can get the...

    Yes but if you have multiple you can get the static pretty low by having more filter area.

    Sent in a state of increasing entropy using Tapatalk:)
  28. Thread: duct design ?

    by R600a
    Replies
    6
    Views
    254

    I don't know your situation but if there's like...

    I don't know your situation but if there's like two returns off of the return plenum then you could put two filter racks to reduce the static. Or my favorite is to use multiple return filter grills....
  29. Thread: Today's Hack Job

    by R600a
    Replies
    7
    Views
    444

    Wow. For some reason that reminds me of a local...

    Wow. For some reason that reminds me of a local restaurant here that I noticed the bathroom stunk and I saw somebody had coated the floor drain in Silicon. I'm pretty sure they did that because...
  30. Replies
    86
    Views
    2,131

    Man i hope we dont start having these problems....

    Man i hope we dont start having these problems. Those are my favorite T stats.

    Sent in a state of increasing entropy using Tapatalk:)
  31. Replies
    86
    Views
    2,131

    The constant power on w1 is normal in heat pump...

    The constant power on w1 is normal in heat pump configuration. You have to use the w2/aux and e.
    I made that mistake once. Then i got a constant heat and cool call. I ended up calling tech support...
  32. Replies
    86
    Views
    2,131

    Ok i must have been thinking wrong. Sent in a...

    Ok i must have been thinking wrong.

    Sent in a state of increasing entropy using Tapatalk:)
  33. Replies
    86
    Views
    2,131

    I dont think that is a valid test unless you...

    I dont think that is a valid test unless you hooked it up to 24 volts but i could be wrong.
    Assuming that you are referring to the t4.

    Sent in a state of increasing entropy using Tapatalk:)
  34. Thread: HEATPIPS in FAHU

    by R600a
    Replies
    9
    Views
    533

    Exactly just a different way of saying it. You're...

    Exactly just a different way of saying it. You're basically taking sensible heat and bypassing it around the coil. So that the coil can remove more moisture.

    Sent in a state of increasing entropy...
  35. Replies
    5
    Views
    206

    Sorry for the elementary question but what is a...

    Sorry for the elementary question but what is a BQ cartridge?

    Sent in a state of increasing entropy using Tapatalk:)
  36. Replies
    86
    Views
    2,131

    You know now that I think about it I think we've...

    You know now that I think about it I think we've had problems on heat pump installs too but if I remember correctly the problem turned out that we were running all of the power through one safety and...
  37. Thread: HEATPIPS in FAHU

    by R600a
    Replies
    9
    Views
    533

    Well i cant say i really understand your...

    Well i cant say i really understand your situation but i am certainly interested.
    What does the heat pipe do? Is it setup to help control humidity by bypassing sensible heat around the coil? If so...
  38. Thread: Tubing Benders

    by R600a
    Replies
    8
    Views
    552

    We had the hilmore and it was my favorite but it...

    We had the hilmore and it was my favorite but it wore out. Now we have yellowjacket and they seem more durable but they dont make quite as nice bends.

    Sent in a state of increasing entropy using...
  39. Replies
    14
    Views
    902

    Since I commented the other day I've been...

    Since I commented the other day I've been thinking about your question and your situation because I had a hard time understanding why you wouldn't use primarily Scrolls in your area.
    I think I may...
  40. Thread: Swaging Tools

    by R600a
    Replies
    21
    Views
    867

    Sounds like you made a good choice. Has...

    Sounds like you made a good choice.

    Has anyone here ever used a swage punch? My boss was talking about using them in the old days.

    Sent in a state of increasing entropy using Tapatalk:)
  41. Replies
    6
    Views
    266

    Do those contacts actually always close together?...

    Do those contacts actually always close together? Because it doesn't make sense to me.

    Sent in a state of increasing entropy using Tapatalk:)
  42. Replies
    14
    Views
    902

    It just got 10% better. Sent in a state of...

    It just got 10% better.

    Sent in a state of increasing entropy using Tapatalk:)
  43. Replies
    14
    Views
    902

    I volunteer to test your compressor in my system...

    I volunteer to test your compressor in my system for free.

    Sent in a state of increasing entropy using Tapatalk:)
  44. Replies
    14
    Views
    902

    Agreed. All i can say is hurry up and produce it...

    Agreed. All i can say is hurry up and produce it because i want to buy it.

    Sent in a state of increasing entropy using Tapatalk:)
  45. Replies
    14
    Views
    902

    Sounds like the new Infiniti variable compression...

    Sounds like the new Infiniti variable compression motor turned compressor.

    Sent in a state of increasing entropy using Tapatalk:)
  46. Replies
    17
    Views
    593

    I wouldn't want to be the one that stepped on the...

    I wouldn't want to be the one that stepped on the needle in the haystack.:-)

    Sent from my rotary telephone using Tapatalk:)
  47. Replies
    86
    Views
    2,131

    Same here you get a bad one every once in a while...

    Same here you get a bad one every once in a while of almost anything.

    Sent from my rotary telephone using Tapatalk:)
  48. Replies
    37
    Views
    2,114

    I know its a foreign thought here in the US. :) ...

    I know its a foreign thought here in the US. :)

    Sent from my rotary telephone using Tapatalk:)
  49. Replies
    24
    Views
    704

    I figured that's what you meant. Sent from my...

    I figured that's what you meant.

    Sent from my rotary telephone using Tapatalk:)
  50. Replies
    24
    Views
    704

    I found some avalible through advanced auto it is...

    I found some avalible through advanced auto it is Behr PAO 68.
    It costs 69$/liter

    Sent from my rotary telephone using Tapatalk:)
Results 1 to 50 of 428