Search:

Type: Posts; User: joemach

Page 1 of 20 1 2 3 4

Search: Search took 0.07 seconds.

  1. Replies
    3
    Views
    93

    WOW! Just WOW! You have got to be kidding!

    WOW! Just WOW! You have got to be kidding!
  2. Replies
    30
    Views
    916

    I know, I have the same issue.

    I know, I have the same issue.
  3. WOW! Thanks!

    WOW! Thanks!
  4. Replies
    12
    Views
    262

    Same thing inside. Different box outside.

    Same thing inside. Different box outside.
  5. Replies
    74
    Views
    2,639

    You know GA, Where I return my 22, they do not...

    You know GA,

    Where I return my 22, they do not seem to mind a mix. I think there is a way they can separate each component.
  6. Replies
    4
    Views
    290

    That is my favorite stat to put in with my...

    That is my favorite stat to put in with my installs. I love the fact that the instructions are right there in the stat. Old green screen version was a pain with 30 or so settings.

    Don't forget to...
  7. I am not sure that you have the problem that the...

    I am not sure that you have the problem that the tech showed you. If the a/c coils rusted through, you would have no air conditioning and no condensation.

    You might just have a clogged drain line...
  8. Mr. Loonie, Where on line did you find a way...

    Mr. Loonie,

    Where on line did you find a way to calculate the savings of HP vs. gas?

    I have been trying to find some sort of comparison software or solution for that.
  9. This looks like it could be a fun project. I like...

    This looks like it could be a fun project. I like doing stuff like this to solve a customers' problems.

    Although I never did anything like this.
  10. One thing about ductless systems that drive most...

    One thing about ductless systems that drive most techs that are not familiar with them nuts is that you cannot measure the pressure and tell anything. If you think it is low on refrigerant, leak...
  11. Replies
    30
    Views
    916

    I say these at Home Depot and was thinking about...

    I say these at Home Depot and was thinking about giving them a try, maybe as a backup.
  12. Replies
    11
    Views
    247

    Not trying to save work or a few bucks on a...

    Not trying to save work or a few bucks on a filter dryer.

    What I am trying to accomplish is saving a homeowner from having to pay for an extra 8 pounds of R-22.

    And yes, if I did replace the...
  13. Replies
    30
    Views
    916

    So I went online and placed an order for 2...

    So I went online and placed an order for 2 different ones. Forgot which ones right now. I will see how they work when they get here.

    I had not idea there were so many flashlight choices. On thing...
  14. Replies
    11
    Views
    247

    Thanks Gary, Those are my thoughts exactly. In...

    Thanks Gary,

    Those are my thoughts exactly. In my demented mind, I was thinking that as long as I could run the system enough to see if there was a temperature difference between the in & out of...
  15. Replies
    16
    Views
    926

    Never heard such a thing. How could setting a...

    Never heard such a thing. How could setting a system up properly be illegal.

    If so you have to set up a "dump zone" to get rid of the excess air. Of course that would be highly inefficient and...
  16. Replies
    11
    Views
    247

    I hear ya.

    I hear ya.
  17. Along with cleaning the blower wheel, I would...

    Along with cleaning the blower wheel, I would also use a coil cleaner and make sure the the indoor coil was as clean as it could be. Just brushing the dirt off the top does not do it. The real dirt...
  18. Replies
    16
    Views
    926

    The 2 thermostats do not indicate multi-stage....

    The 2 thermostats do not indicate multi-stage. They indicate multi-zone.

    But it sounds to me like there is no bypass installed so that when only one zone is demanding heat or cool, it has no place...
  19. Replies
    23
    Views
    10,076

    I have done this numerous times with equalized...

    I have done this numerous times with equalized tube (ones that were brazed into the suction line) on replacement TXV's with no issues.

    Using a long coupler would prevent brazing from rolling into...
  20. You should talk with the owner of the installing...

    You should talk with the owner of the installing contractor and let him know the issue you are having. He needs to send out someone who is knowledgeable your system. Don't give up hound him until he...
  21. Replies
    11
    Views
    247

    Thanks. Good advice. Of course if the system...

    Thanks. Good advice.

    Of course if the system is flat it would get a new filter dryer. This system is not. I always use nitro and pull way below 500 microns.

    Here is my concern...

    If I pump...
  22. Replies
    11
    Views
    247

    Silly question...

    I know that whenever I break into an hvac system to do a repair or replace a component, I need to replace the filter dryer. But what if that filter dryer is in the condenser like many manufacturers...
  23. Replies
    85
    Views
    1,702

    Hope I never have to deal with that. New coil or...

    Hope I never have to deal with that. New coil or new condenser/evaporator.

    I have lost enough hair already.
  24. Replies
    30
    Views
    916

    Thanks guys, lots of great options. Tired of...

    Thanks guys, lots of great options.

    Tired of the crappy ones that don't work all the time.

    I would like to find one that uses 1 AA battery.

    Also, I don't need the strobe or high and low....
  25. Replies
    30
    Views
    916

    Pocket flashlight

    I am wondering what pocket flashlight you guys like. I keep buying expensive ones and they don't work when I need them.
  26. Replies
    41
    Views
    2,087

    I have a Hilmor 1839079. It is a little on the...

    I have a Hilmor 1839079. It is a little on the heavy side, but quite durable. Solid bottom and no matter how bad I treat it, never a tear or problem with zipper. It carries just about everything I...
  27. Replies
    4
    Views
    374

    Like your graphic.

    Like your graphic.
  28. Replies
    4
    Views
    374

    As far as I recall, on the latest version...

    As far as I recall, on the latest version (version 3) you need to set up the wi-fi first before you can program the stat. I think prior the version 3 you could program the stat first.
  29. I think this guy is making some sort of joke. ...

    I think this guy is making some sort of joke.

    There is no defrost mode on a geo.
  30. Replies
    18
    Views
    408

    Yes, Nest will handle 2 stage plus back up heat....

    Yes, Nest will handle 2 stage plus back up heat.

    But I can not recommend Nest as a thermostat.

    Some of the weirdest issues I have ever seen. One was after a recent firmware update, the fan...
  31. Replies
    18
    Views
    408

    The setting you are looking for is on page 15 -...

    The setting you are looking for is on page 15 - setting #670 will lock out the thermostat.
    Setting 600 & 610 allows you to limit the temp. But once you lock it out on setting 670, the temp can not...
  32. Replies
    41
    Views
    2,087

    I am starting to go the same way. I only ever...

    I am starting to go the same way. I only ever used 3 or 4 of the 20+ tools I have in the bag. It was getting ridiculous. So now I have a bag with the very basic things I need on every call like...
  33. Replies
    8
    Views
    285

    Trying to figure out what you have a condensate...

    Trying to figure out what you have a condensate pump on a ductless system.

    Also there is an app to test dB, seems pretty accurate.
  34. Replies
    16
    Views
    570

    Since the installing contractor can not seem to...

    Since the installing contractor can not seem to solve your issues...

    Sounds like you need an independent evaluation of the system and the configuration. Including the items mentioned above by...
  35. I don't rebuild. They are cheap enough that every...

    I don't rebuild. They are cheap enough that every few years I can just buy a new set of them.
  36. Nice, well laid out ad for techs. Are you...

    Nice, well laid out ad for techs.

    Are you hiring in all those locations?
  37. I have never waited more than an hour. Great...

    I have never waited more than an hour. Great support.
  38. Get the technician back that replaced the fan and...

    Get the technician back that replaced the fan and see if he can find the issue. Very difficult from over here across the internet to diagnose such an issue.

    Just need to look harder.

    That said,...
  39. Something is odd. Normally, if it works well for...

    Something is odd. Normally, if it works well for a month it should keep doing so.

    Sorry, not much help.

    Have your tech call tech support at Mitsubishi, they will get him to solve it.

    Good...
  40. I do not like auto mode. I do not want to give up...

    I do not like auto mode. I do not want to give up control to a circuit board. Set them all to cool and see what happens. One might be trying to heat, not there - don't know for sure.
  41. I have used it a few times with success. But I...

    I have used it a few times with success. But I do tell the customer that the system needs replacing. If that is not in the budget right now, the leak seal is a "Hail Mary" solution. It might work,...
  42. Double check your controllers and make sure they...

    Double check your controllers and make sure they are all set on the same mode. If not, this will confuse the system.
  43. Replies
    4
    Views
    359

    Great idea to get started with and see how that...

    Great idea to get started with and see how that goes. Thanks!

    I was trying to find some springs for under the unit locally, but all they have is springs for hanging an indoor unit. Do you know...
  44. Replies
    4
    Views
    359

    How to quiet a noisy system

    I have a York Split on a roof that is making too much noise for the tenant. It is even shaking the wall below.

    York Model #: E3FB090A25A
    Serial #: NON6303263

    I thought it was the fan blade &...
  45. You need to start you own thread. Otherwise no...

    You need to start you own thread. Otherwise no one will see your post.
  46. I believe you are thinking too hard. As far as...

    I believe you are thinking too hard.

    As far as return... you can not oversize.

    On my slim ducted units (ducted mini-splits), I do ceiling returns as close to the unit as possible. This gives...
  47. Replies
    8
    Views
    621

    Was dark & late and could not figure out the...

    Was dark & late and could not figure out the wiring. Dead compressor, so getting new condenser unit.
  48. Replies
    8
    Views
    621

    OK. That makes sense now. This is a 3 zone...

    OK. That makes sense now.

    This is a 3 zone dual fuel setup.

    Thanks for the explanation.

    Just never say this before
  49. Thread: Yank-a-lineset

    by joemach
    Replies
    15
    Views
    1,983

    That is a good idea regardless of the brand.

    That is a good idea regardless of the brand.
  50. Replies
    8
    Views
    621

    Anyone ever see this before?

    This is on a Trane:

    M- 4TWX6036B1000AA
    S- 62115KN2F

    Can't figure out what these are doing809458
Results 1 to 50 of 1000