Search:

Type: Posts; User: lkapigian

Page 1 of 19 1 2 3 4

Search: Search took 0.12 seconds; generated 7 minute(s) ago.

  1. Replies
    2
    Views
    143

    External driers should always be installed, the...

    External driers should always be installed, the internal drier is Not a replacement or "in lieu of" an external drier...they would be OK if the install is Pristine and Sanitary ( regarding piping...
  2. Replies
    3
    Views
    127

    pretty much a hack install, and you should never...

    pretty much a hack install, and you should never "blank Off" especially if that fan discharges where the blank off is

    I imagine there are other issues but we would need to know static and airflow...
  3. Replies
    209
    Views
    3,171

    I can say I have been around it for 40 years and...

    I can say I have been around it for 40 years and in my observations have only seen some really good recipe's and cooks come from it
  4. Replies
    12
    Views
    325

    Developers want to pad the bottom line,...

    Developers want to pad the bottom line, theirs......

    you can always shop it both ways and not go one route only based upon an assumption

    spend it upfront or pay it in the end with headaches
  5. Replies
    12
    Views
    325

    Cant discuss pricing , but I am frequently more...

    Cant discuss pricing , but I am frequently more than a union shop

    Pricing is not always an indicator,but you can usually bet that when someone is the fraction the cost of another, they have left...
  6. Replies
    12
    Views
    325

    You can expect union work to be top notch all the...

    You can expect union work to be top notch all the way, you typically don't see hack work, that being said ( as an ex union fitter) our non union work parallels what you will see in a union shop
    ...
  7. Replies
    209
    Views
    3,171

    Coincidence maybe, but if overtime smoking dope...

    Coincidence maybe, but if overtime smoking dope leads you to do this, I hardly think that occured to these young shooters so quickly

    They were/are nuts to begin with..........I imagine you can say...
  8. Replies
    209
    Views
    3,171

    I'm sorry , the only thing weed leads to is...

    I'm sorry , the only thing weed leads to is overeating

    That being said there are tweekers that smoke dope, but you will not find an aggressive pothead
  9. non oem motor, we wont do that..but if the RPM...

    non oem motor, we wont do that..but if the RPM and all dimensions are correct it will function
  10. You need pro status to post a reply to a thread...

    You need pro status to post a reply to a thread other than one you started in AOP
  11. Replies
    17
    Views
    938

    We stay away from GD’s and go owner direct, put...

    We stay away from GD’s and go owner direct, put that extra % with us
  12. Replies
    54
    Views
    1,789

    I'll send you some pictures when I get back to...

    I'll send you some pictures when I get back to town Tuesday
  13. Replies
    54
    Views
    1,789

    Oversize them and the effect is negligible, I've...

    Oversize them and the effect is negligible, I've had these on for 20 years
  14. Replies
    54
    Views
    1,789

    I can get one but just custom made screens from a...

    I can get one but just custom made screens from a screen shop
  15. Replies
    9
    Views
    234

    There should not be much of a load , r13...

    There should not be much of a load , r13 partition which is treated as a North exposure and a ceiling if single story ....wold be no where near 5 tons
  16. Replies
    54
    Views
    1,789

    We take care of a cotton facility, we install...

    We take care of a cotton facility, we install mesh screens on the air cooled condensers with spare sets the maintenance staff cleans every few weeks like a lint screen on a drier
  17. Replies
    9
    Views
    234

    If an apartment hall, the walls are treated as...

    If an apartment hall, the walls are treated as partition , not interior as you have to assume vacancies and the space may become unconditioned
  18. Our Carrier Supplier, Sigler, was the last living...

    Our Carrier Supplier, Sigler, was the last living Carrier dealer to have worked with Willis Carrier. Russel past a couple years ago in his late 90s but worked at his Carrier dealership daily...I was...
  19. Replies
    5
    Views
    277

    you can go smaller outside bigger inside but not...

    you can go smaller outside bigger inside but not visa versa
  20. Replies
    22
    Views
    1,132

    High SC and SH usually indicates a restriction

    High SC and SH usually indicates a restriction
  21. We have our supplier and they have their own tech...

    We have our supplier and they have their own tech people that work with Carrier Directly and they do make visits to the home UNDER the 100% Satisfaction Program IF your contractor is part of that
  22. Thread: My Wife :-)

    by lkapigian
    Replies
    12
    Views
    1,165

    Ouch

    Ouch
  23. but his cooling IDB is 72, should be 75

    but his cooling IDB is 72, should be 75
  24. Replies
    4
    Views
    160

    If you have the liquidity, get a air handler for...

    If you have the liquidity, get a air handler for the roof,it will likely have to be special made/ordered

    In Ca where I am we are heavy into SPP ( though I prefer spilt's ) Noise and weight are...
  25. Not a big deal with the lower design on heating,...

    Not a big deal with the lower design on heating, I am a stickler on cooling ..........Contractor A report gives me a headache looking @:cheers:
  26. Thread: High Static

    by lkapigian
    Replies
    2
    Views
    200

    if you are reading it correctly, personally I...

    if you are reading it correctly, personally I would not worry about .67
  27. Replies
    4
    Views
    160

    They are available, but I would still go SPP

    They are available, but I would still go SPP
  28. If ducts are in the attic Contractor B is going...

    If ducts are in the attic Contractor B is going to be way off on second floor, negligible on the first but still off on the first
  29. Contractor B used the correct Indoor design, not...

    Contractor B used the correct Indoor design, not knowing what your city id 1% can vary , looks like B chose Boston AP are you close to that?

    I see 0 duct load, are they in a conditioned space? 0...
  30. dehumid or ventilation setting

    dehumid or ventilation setting
  31. Post the complete reports .dont game Manual J

    Post the complete reports .dont game Manual J
  32. cant discuss prices but if it is an old unit 20+...

    cant discuss prices but if it is an old unit 20+ probably didn't matter other than they should have looked indoors for a leak...we don't charge by the pound but rather a flat rate
  33. Replies
    11
    Views
    363

    I agree, we'd put it in and return also there is...

    I agree, we'd put it in and return also there is the option of making a smaller or larger one out of 2 or more capacitors, to many techs just don't know how.............
  34. first contractor used wrong cooling design , no...

    first contractor used wrong cooling design , no idea about 3- would be nice to see the full report
  35. Replies
    11
    Views
    363

    lots of things are done all the time that are...

    lots of things are done all the time that are incorrect....40% over is pretty significant
  36. Replies
    11
    Views
    363

    5% + on capacitance is ok voltage over is fine no...

    5% + on capacitance is ok voltage over is fine no matter, if it were me, i'd go back with the right size MFD
  37. call a tech and have it looked over

    call a tech and have it looked over
  38. don't shut the ac off when you leave and expect...

    don't shut the ac off when you leave and expect it to reach those temps- It is a "conditioner" , let the space acclimate - everything in the home has mass and you are adding heat ( both sensible and...
  39. Replies
    14
    Views
    862

    I did, started in 1980

    I did, started in 1980
  40. Replies
    14
    Views
    862

    Its just a revenue generator for non covered...

    Its just a revenue generator for non covered items " they probably just use a recovery rag when they do
  41. Thread: Smart vents

    by lkapigian
    Replies
    5
    Views
    342

    Could damage the system, I would not install...

    Could damage the system, I would not install without analyzing the duct system first
  42. Replies
    14
    Views
    862

    Its because they rape the HO's with outrageous...

    Its because they rape the HO's with outrageous "Extra Charges" such as recovery , they are just shopping it out, we get those calls daily
  43. I wished we could get 50% , California is 10% or...

    I wished we could get 50% , California is 10% or $1000.00 whichever is less no matter the size of the job
  44. OSHA does not have a specific standard that...

    OSHA does not have a specific standard that covers working in hot environments. Nonetheless, under the OSH Act, employers have a duty to protect workers from recognized serious hazards in the...
  45. Replies
    21
    Views
    1,201

    looks like its by passed as well---plenty of...

    looks like its by passed as well---plenty of crosses that will work , doesn't have to be Ranco
  46. Server will be back up 6/28/19

    Server will be back up 6/28/19
  47. Replies
    8
    Views
    605

    as of today it should be up 6/28/19

    as of today it should be up 6/28/19
  48. No

    No
  49. Replies
    13
    Views
    418

    you are not, just trying to help IF you are a...

    you are not, just trying to help IF you are a tech, Post in Tech to Tech , AOP ( Ask Our Pros ) is for homeowners non DIY.....If you are a tech, get your post count up and apply for pro membership,...
  50. Replies
    13
    Views
    418

    since this is in AOP,I would suggest a request to...

    since this is in AOP,I would suggest a request to move to Tech to Tech
Results 1 to 50 of 937