Search:

Type: Posts; User: pecmsg

Page 1 of 20 1 2 3 4

Search: Search took 0.27 seconds.

  1. Replies
    10
    Views
    369

    That's the need for a dehumidifier and the...

    That's the need for a dehumidifier and the smallest mini!
  2. Replies
    4
    Views
    57

    They pay for the level of experience one way or...

    They pay for the level of experience one way or the another!
  3. Replies
    4
    Views
    57

    Get it from a dealer, let them install it and...

    Get it from a dealer, let them install it and warranty it. Might as well have the equipment serviced at the same time!
  4. The tech servicing your furnace should have a...

    The tech servicing your furnace should have a personal CO monitor on him! Ask him / her what its reading?

    There are several Low Level CO monitors on the market.

    Defender is one
  5. Replies
    8
    Views
    327

    What about the minimum line set length?

    What about the minimum line set length?
  6. Looks good is not even close! You need someone on...

    Looks good is not even close! You need someone on site with the proper test equipment!
  7. https://www.iuoe.org/our-locals/find-an-iuoe-local...

    https://www.iuoe.org/our-locals/find-an-iuoe-local-union

    http://www.ua.org/locals
  8. What is it shutting off on? If a safety then...

    What is it shutting off on? If a safety then there's an issue.

    When was the last time it was serviced?
  9. Replies
    15
    Views
    393

    Its the amount of air that can pass thru the...

    Its the amount of air that can pass thru the filter. 1" Pleated are advertised as being able to clean the air but that's not the purpose of the filter. Its just keep large pieces of dust and debris...
  10. Replies
    15
    Views
    439

    [QUOTE=evict;25817959] Sorry but schooling and...

    Sorry but schooling and reading is not even 1/2 of the training needed. Don't know how the test is on the left coast but here the 2 FDNY guys will chew you up and spit you out. They can smell On The...
  11. For a contractor like that paying a little more...

    For a contractor like that paying a little more is well worth it! Glad it worked out.
  12. Replies
    11
    Views
    273

    Counting the weeks until my 1st Social Security...

    Counting the weeks until my 1st Social Security check :grin2:

    Keep Contributing!
  13. Replies
    1
    Views
    79

    Anything with Minis forget the internet call the...

    Anything with Minis forget the internet call the factory!
  14. Replies
    11
    Views
    273

    Fixed :whistle:

    Fixed :whistle:
  15. Replies
    11
    Views
    273

    That's because he knows nothing!

    That's because he knows nothing!
  16. Thread: Walk in Freezer

    by pecmsg
    Replies
    3
    Views
    87

    https://hvac-talk.com/vbb/showthread.php?158850-Go...

    https://hvac-talk.com/vbb/showthread.php?158850-Got-Questions-Help-Us-Help-You-Please-Read-Before-Asking-A-Technical-Question!
  17. Replies
    15
    Views
    393

    Why turn it off? No furnace is designed for that...

    Why turn it off? No furnace is designed for that large of a temperature swing! Id also add any larger swing and there could be condensation issues.
    Loose the Pleated furnace killing filter, the air...
  18. Thread: Walk in Freezer

    by pecmsg
    Replies
    3
    Views
    87

    What temperatures go with those pressures? ...

    What temperatures go with those pressures?

    Whats the SH at the compressor?
    Whats the oil pressure at start up and 2, 5 and 10 mins later?

    Evaporator clear?
    Fan(s) turning right direction?
  19. How did that system cycle at design conditions?...

    How did that system cycle at design conditions? every 15, 30 45 mins or run continues? Same question for the cooling cycles.

    Any issues with different temps upstairs or down (I assume this is a 2...
  20. Replies
    13
    Views
    437

    The issue with brazing is Copper Oxide forming....

    The issue with brazing is Copper Oxide forming. Small pieces of burnt copper flowing around the system, plugging strainers and god forbid if they get into bearings can destroy them. This is why a N2...
  21. Replies
    7
    Views
    326

    In Tx I hope another was installed!

    In Tx I hope another was installed!
  22. Without being there to actually see the "System"...

    Without being there to actually see the "System" we can only guess. Was it properly installed and maintained? is the duct design correct? Have any envelope improvements been made?

    Evaporators do...
  23. Replies
    15
    Views
    425

    and he'll be the first one to sue when something...

    and he'll be the first one to sue when something goes wrong!
  24. Replies
    15
    Views
    425

    So your calling the Building department, getting...

    So your calling the Building department, getting a permit and having it inspected?
  25. https://www.law.cornell.edu/cfr/text/46/56.50-103

    https://www.law.cornell.edu/cfr/text/46/56.50-103
  26. Easy you call a different contractor!

    Easy you call a different contractor!
  27. Summer weight oil? My systems operate at 0 deg...

    Summer weight oil?
    My systems operate at 0 deg outside air.

    Get a different contractor
  28. Replies
    13
    Views
    437

    So how do you fix a brazed connection?

    So how do you fix a brazed connection?
  29. Replies
    15
    Views
    393

    Find a different contractor. Using the furnace...

    Find a different contractor. Using the furnace during construction is not good. The unit probably needs a good cleaning.
  30. Replies
    16
    Views
    373

    Hitting the guys pretty hard arenít you?

    Hitting the guys pretty hard arenít you?
  31. Replies
    16
    Views
    373

    Same issue?...

    Same issue?
    https://hvac-talk.com/vbb/showthread.php?2214677-Help!!!!!!-furnace-thermostat-issue&p=25817561#post25817561
  32. Replies
    8
    Views
    2,957

    *

    *
  33. Replies
    2
    Views
    185

    For brazing none required For burning steel...

    For brazing none required

    For burning steel dark lenses recommended / required
  34. Replies
    9
    Views
    349

    Probably was R-12 but with no markings its...

    Probably was R-12 but with no markings its anyone's guess. Pull the remaining charge, change the drier and use any of the R-12 replacements. Unless you change the oil avoid R-134A
  35. Its very easy, do what you want

    Its very easy, do what you want
  36. Not an attitude but opinion Outdoor reset...

    Not an attitude but opinion
    Outdoor reset controls readily available
    Fan sensors also available

    Maybe Iím thinking in too simple terms!
  37. Again you stated your an engineer itís not that...

    Again you stated your an engineer itís not that hard!
  38. There are several ways of doing it. Unfortunately...

    There are several ways of doing it. Unfortunately we. Youíve been given a few. Unfortunately we canít get into details.
  39. Please call for service.

    Please call for service.
  40. For an engineer Iím not overly impressed!

    For an engineer Iím not overly impressed!
  41. After market humidastats eill!

    After market humidastats eill!
  42. Adapt a generator Auto Start No power to the...

    Adapt a generator Auto Start

    No power to the 5-HP back up start the gas motor, Pressure switch / centrifugal Switch then disengages the starter!
  43. Current sensor or sail switch. Blower and circ...

    Current sensor or sail switch.

    Blower and circ at the same time leads to cold air for a while. Get a ARGO with sensor or t-stat to control the fan.

    If that units in the attic let the t-stat...
  44. Sail Switch or Current Sensor. A relay will...

    Sail Switch or Current Sensor.

    A relay will work as well!
  45. Replies
    13
    Views
    454

    They make it compliant!

    They make it compliant!
  46. Replies
    6
    Views
    291

    Im betting oversized on undersized ducts!

    Im betting oversized on undersized ducts!
  47. They make a sensor that goes on the fan to tell...

    They make a sensor that goes on the fan to tell the humidifier its OK to run.

    A bucket of spiced water on the wood stove is easier!
  48. :cheers:

    :cheers:
  49. Replies
    10
    Views
    282

    I wouldn't consider replacement right now. Is it...

    I wouldn't consider replacement right now. Is it oversized............Probably just like the ducts are undersized. Bad duct design leads to ECM failures but 12 years is a good run so don't make hasty...
  50. Replies
    10
    Views
    282

    the cost of the motor is one thing, the labor to...

    the cost of the motor is one thing, the labor to install it, troubleshooting to find the reason it failed, warranty. What does that $15 burger cost?

    As far a replacing that a different story,...
Results 1 to 50 of 1000