  1. Replies
    7
    Views
    213

    First think you need to do before anything else...

    First think you need to do before anything else is to take a photo of that install and post it in the wall of shame thread.

    Second thing you should do is ask him what he thinks about the install...
  2. Replies
    24
    Views
    831

    Drill or impact

    Lol, I love your idea of a quiet atmosphere. For instance every time I have a nice book I want to read I always head over to my local casino and find a quiet table to sit at. I usually find one right...
  3. Replies
    23
    Views
    17,555

    Itís funny how we tell people to use the search...

    Itís funny how we tell people to use the search function instead of asking the same question over and over again, but then we shame them for finding those old threads and continuing them after having...
  4. Replies
    6
    Views
    420

    I did something similar with an adjustable wrench...

    I did something similar with an adjustable wrench before I found out Sporlan makes wrenches for that purpose but those ones have short handles so the ones you made might be easier to use (and...
  5. Replies
    13
    Views
    706

    I find this humerus Sent from my iPhone...

    I find this humerus


    Sent from my iPhone using Tapatalk
  6. Replies
    3
    Views
    228

    Tell us more about this room. Whatís inside it?...

    Tell us more about this room. Whatís inside it? Whatís on the other side of the walls? What are the smells from?


    Sent from my iPhone using Tapatalk
  7. Replies
    24
    Views
    831

    I use the impact for sheet metal screws all the...

    I use the impact for sheet metal screws all the time. You want high speed to drive a point screw easily.

    I prefer the chuck drill best for everyday use but it is heavier and slightly larger so it...
  8. Replies
    13
    Views
    645

    Our training is paid for and our time is also...

    Our training is paid for and our time is also paid for while we are at that course. The union and employer pay for the training and wages.


    Sent from my iPhone using Tapatalk
  9. Thread: Buying tools

    by thatguy
    Replies
    16
    Views
    817

    Buying tools

    Union agreement that Iím in says the employer can either supply the tools or provide a tool allowance. My current employer supplyís our tools, my previous employer payed us $0.80 per hour for to buy...
  10. Replies
    17
    Views
    1,004

    OHhhhhh... I see what you see now! I was all...

    OHhhhhh... I see what you see now! I was all flipped upside down and backwards.

    That explains the ďwonky capĒ... turns out itís not a cap at all, Itís the rotating doo-hicky! :)


    Sent from my...
  11. Replies
    17
    Views
    1,004

    Are you sure itís an SEH? Looks like a powerhead...

    Are you sure itís an SEH? Looks like a powerhead on the end of that valve... is that the bottom view where the stem would typically be? No need for a stem and spring assembly in an EEV. I would have...
  12. Replies
    17
    Views
    1,004

    Is that ice? Break it off and check for a leak?...

    Is that ice? Break it off and check for a leak? Doesnít look like itís has ice anywhere else, but itís hard to tell from the picture.


    Sent from my iPhone using Tapatalk
  13. Replies
    50
    Views
    2,137

    Our company wonít do that because it incentivizes...

    Our company wonít do that because it incentivizes dishonest work and can lead techs to replacing components that are not required to be replaced or padding a repair with additional components.

    ...
  14. With the right equipment you can do anything. You...

    With the right equipment you can do anything. You would need to design some circuitry yourself though but the components are available and in use to make it happen.

    What are you planning to do...
  15. Replies
    28
    Views
    1,861

    Made in USA arenít they? Sent from my iPhone...

    Made in USA arenít they?


    Sent from my iPhone using Tapatalk
  16. I carry that same wrap on silver wire connectors...

    I carry that same wrap on silver wire connectors material in my truck. Didnít even know what it was for. Next time there are too many wires to fit into a nut, now I know what to do!


    Sent from my...
  17. Replies
    28
    Views
    1,861

    What are considering factors when looking at...

    What are considering factors when looking at reclaim units?

    Do they all pump liquid?

    Is there a rating as to how fast they pump?

    Do they all have a purge function?

    Do they all have a...
  18. Iím impressed by the size of the paint pot the...

    Iím impressed by the size of the paint pot the roofers provided for the install. Did they think they would need to fish the whole condenser through the roof?


    Sent from my iPhone using Tapatalk
  19. Replies
    7
    Views
    342

    What are your pressures? Sent from my iPhone...

    What are your pressures?


    Sent from my iPhone using Tapatalk
  20. Replies
    7
    Views
    342

    Aqualogic Delta Star Heat Pump DSHP

    You are only running 2deg F delta through your water coil. With an entering water temp of 40 your exiting temp will only be 38. Unless you have a restriction or lose water flow I would think you...
  21. Replies
    6
    Views
    369

    That wouldnít be necessary Sent from my...

    That wouldnít be necessary


    Sent from my iPhone using Tapatalk
  22. Replies
    95
    Views
    8,823

    If the customer requires me to take my tools out...

    If the customer requires me to take my tools out of my van to preform the job they are asking me to do then they are the ones who pay for my time to put those tools back. If my van becomes a mess...
  23. Replies
    6
    Views
    369

    We canít provide DIY advice on how to do it but...

    We canít provide DIY advice on how to do it but what you are asking to do sounds possible with one thermostat, one transformer, and some relays. The setup would differ depending on the wiring...
  24. Replies
    7
    Views
    407

    We stock our trucks with the common parts and...

    We stock our trucks with the common parts and often use currier services if our drivers are busy. Sometimes itís cheeper to use a currier than it is to send our own driver.

    We take the vehicles...
  25. Replies
    7
    Views
    342

    Do you have a model number? What is the freeze...

    Do you have a model number?

    What is the freeze point of your brine?

    Are you able to increase flow through the evaporator?


    Sent from my iPhone using Tapatalk
  26. Replies
    7
    Views
    563

    It can be spongy but we use that to our...

    It can be spongy but we use that to our advantage. If the shaft isnít kept oiled then it can bind a little when you drop loads down. Also if you are pulling it to the side then that can add friction...
  27. Replies
    7
    Views
    563

    They are great for working in tight areas and...

    They are great for working in tight areas and easy to carry down narrow hallways to bring them to the equipment being worked on.

    We have a few of them. One of them we cut the legs down so it will...
  28. Replies
    7
    Views
    563

    Small material lifts

    We use the co2 genie lifts. Converted them to use our N2 for convenience.
    We use it to lift WSHP units all the time

    Sent from my iPhone using Tapatalk
  29. Replies
    9
    Views
    516

    Common HVAC Types in mid-priced hotels

    Very thorough research for an upcoming vacation? :)


    Sent from my iPhone using Tapatalk
  30. Replies
    28
    Views
    1,861

    I use yellow jacket. It has an auto off switch to...

    I use yellow jacket. It has an auto off switch to turn itself off when itís recovered. Tank float switch connection, liquid or vapor recovery, and itís fast (although I havenít used many others to...
  31. Replies
    9
    Views
    516

    Ahh, right, low end hotels... Around here Iíve...

    Ahh, right, low end hotels... Around here Iíve seen them have PTAC units. Maybe mid range also, I donít service any of those hotels, and apparently I donít get out much.


    Sent from my iPhone...
  32. Replies
    9
    Views
    516

    I see mostly WSHP and chilled water fan coils in...

    I see mostly WSHP and chilled water fan coils in my parts.


    Sent from my iPhone using Tapatalk
  33. Replies
    6
    Views
    412

    You learn different stuff in school than what you...

    You learn different stuff in school than what you learn OTJ. You need to do both.

    I agree with the suggestions to join a union. You will often come out ahead if you take that path. In my area I...
  34. Thread: Doyle crimps

    by thatguy
    Replies
    18
    Views
    2,280

    I just picked up a new set of Klein crimpers like...

    I just picked up a new set of Klein crimpers like you show (but now they also have a wire stripper incorporated below the pivot point. The problem with them though is that the tips donít touch. Canít...
  35. Thread: Doyle crimps

    by thatguy
    Replies
    18
    Views
    2,280

    I had the same screw driver. I got to use it one...

    I had the same screw driver. I got to use it one time. It literally didnít even undo its first screw that I tried to undo with it before the tip snapped off.


    Sent from my iPhone using Tapatalk
  36. Thread: Rudd fan issue

    by thatguy
    Replies
    2
    Views
    297

    Could be a program issue on your tstat. Iíve come...

    Could be a program issue on your tstat. Iíve come across some that behave this way in certain instances.


    Sent from my iPhone using Tapatalk
  37. Replies
    12
    Views
    639

    Anyone else get this?

    I see... A building in heat can be a challenging beast to tame. It happens to all of them though so itís best to just prepare for it before it occurs. For now, itís probably best to just keep your...
  38. Replies
    8
    Views
    602

    I use a dual Fluke setup (322 clamp, 16 DMM). I...

    I use a dual Fluke setup (322 clamp, 16 DMM). I keep the amp clamp on my belt loop and a pocket of tools for most inspections that Iím familiar with. I bring out the bag that has the DMM and otter...
  39. Replies
    4
    Views
    348

    Forum rules specify we canít advise DIY...

    Forum rules specify we canít advise DIY instructions on how to fix your problem. We can say that it doesnít sound like its operating correctly and it sounds like it could benefit from having a...
  40. Replies
    26
    Views
    1,069

    Is it classified as storage water heating...

    Is it classified as storage water heating equipment when it doesnít store hot water? Such as a continuous water heating system?


    Sent from my iPhone using Tapatalk
  41. Replies
    26
    Views
    1,069

    You may have less of an issue with high pressure...

    You may have less of an issue with high pressure if you use plastic pipes. PEX for example may have enough flex in it to absorb a small amount of temperature fluctuations. This is just a guess though...
  42. Replies
    26
    Views
    1,069

    Thatís fine for the times when you use hot water,...

    Thatís fine for the times when you use hot water, but there are times when only cold water is used. Washing vegetables, watering the lawn, etc. That can create a large volume of cold water that will...
  43. Replies
    13
    Views
    1,059

    Forgive me for my looking up the numbers... ...

    Forgive me for my looking up the numbers...

    Have you checked the flame rod if that is what it is using for flame verification? May be on the cusp of needing replacement or cleaning?

    Also have...
  44. Replies
    26
    Views
    1,069

    Iíve seen a short 30í run of 1/2Ē copper line...

    Iíve seen a short 30í run of 1/2Ē copper line rise from 30psi to over 125psi as it warm to the rooms ambient temperature. I donít recall exactly what pressure it finally reached when I discovered the...
  45. Replies
    26
    Views
    1,069

    Unless your local codes say otherwise, Your house...

    Unless your local codes say otherwise, Your house only needs it if you have a check valve on your city supply line. This is most commonly fond in your water meter, or anywhere after a check valve on...
  46. I guess I wasnít very clear. In the product...

    I guess I wasnít very clear.

    In the product specs for the 87v Max that you posted, it has a comparison chart that lists the specs of the 87V and the 87v Max, side by side.

    The side by side...
  47. In the first link you posted it says the 87v will...

    In the first link you posted it says the 87v will withstand a 3 meter drop... I donít think it was designed for that.

    They also mentioned that it has every feature that he 87v has, except it only...
  48. Replies
    7
    Views
    328

    There are lots of different ways they can be...

    There are lots of different ways they can be installed. For instance, they can be incorporated into an existing ducted furnace so it uses the existing duct work, it can be a stand alone setup where...
  49. Fluke 87V-MAX vs 28II ??? (87V MAX... apparently it's a thing)

    It seems fluke has released an 87V MAX DMM but I can't figure out what the difference is between the 87V MAX and the 28II

    Has anyone noticed this meter before? it looks like it only came out...
  50. Replies
    19
    Views
    877

    Two infrared heaters for one room?

    I think itís the fire hazard associated with the plug in type devices that has caught the attention of the insurance agencies.

    Let them know what you want the HP to do so they are aware of its...
Results 1 to 50 of 665