  1. Replies
    0
    Views
    1

    Anybody know of a short air handler?

    I have a real tight situation for a change out.

    I need to find an air handler that is less than 36" tall.

    This will need to be 4 position so I can do a horizonal.

    I think Rheem/Russ used to...
  2. Never looked at it that way, but if I think about...

    Never looked at it that way, but if I think about it, you are correct.
  3. Interesting Terry, I do pretty much the same....

    Interesting Terry,

    I do pretty much the same. If they ask How Much before I get started that is a red flag.

    Sometimes I give a ball park about if they ask, but most of the time they just want...
  4. Replies
    19
    Views
    1,264

    Thank You!

    Thank You!
  5. Replies
    19
    Views
    1,264

    Couldn't there be a restriction further...

    Couldn't there be a restriction further downstream? Like a filter/dryer inside at the evap coil or even a plugged TXV?

    Wouldn't the restriction stack subcooled refrigerant back to the condenser?
    ...
  6. Replies
    19
    Views
    1,264

    Couldn't there be a restriction further...

    Couldn't there be a restriction further downstream? Like a filter/dryer inside at the evap coil or even a plugged TXV?

    Wouldn't the restriction stack subcooled refrigerant back to the condenser?
  7. Replies
    19
    Views
    672

    They were hardy beasts, weren't they?

    They were hardy beasts, weren't they?
  8. Replies
    5
    Views
    317

    The quietest system that I know of would be a...

    The quietest system that I know of would be a Bosch.
  9. Thread: OK. I give up!

    by joemach
    Replies
    15
    Views
    509

    But that does not explain the higher supply temp....

    But that does not explain the higher supply temp. That is what really has me stumped.

    Even if there is a leak or kink, where is this hot air coming from?

    I will see if I can stop by tomorrow...
  10. Thread: OK. I give up!

    by joemach
    Replies
    15
    Views
    509

    I guess it is possible, but unlikely. Top takeoff...

    I guess it is possible, but unlikely. Top takeoff from ductboard to 5' flex duct (in joust cavity) to floor boot.
  11. Thread: OK. I give up!

    by joemach
    Replies
    15
    Views
    509

    Good point. I thought about that. May not even be...

    Good point. I thought about that. May not even be my issue. Might have to do with something the dry waller did.



    No branch. This supply run comes right off the main trunk running along the...
  12. Thread: OK. I give up!

    by joemach
    Replies
    15
    Views
    509

    OK. I give up!

    This one really has me baffled.

    My install several months ago. Gas furnace with a/c in basement 2 returns in the wall. Floor supplies in each room. Works fine in heat. A/c season starts and there...
  13. Replies
    54
    Views
    1,980

    But I think a lot of those old systems had...

    But I think a lot of those old systems had undersized vapor lines which increased velocity.
  14. When you set up the Bosch for the Durham...

    When you set up the Bosch for the Durham property, you set the dipswitch for 2 ton. It will modulate down to the demand of 1.5 tons if that is what is requited.

    Bosch only makes 3 & 5 ton outdoor...
  15. Replies
    111
    Views
    2,387

    AFAIK, it would be a violation of the HIPAA Law....

    AFAIK, it would be a violation of the HIPAA Law.

    You would be exposing your heath info.
  16. I am wondering with units on 3 separate floors,...

    I am wondering with units on 3 separate floors, what is the total overall length of the copper refrigerant lines. I think there is a limit to how long the lines can be. The system comes pre-charged...
  17. Are you getting any flashing lights on the indoor...

    Are you getting any flashing lights on the indoor unit?
  18. Replies
    7
    Views
    408

    My bet is that you have a ductwork issue. With...

    My bet is that you have a ductwork issue.

    With a variable speed blower motor, if there is some restriction in air flow, the motor will ramp up and try to overcome the ductwork issue.
  19. Replies
    7
    Views
    408

    Need someone to do a Manual J & D.

    Need someone to do a Manual J & D.
  20. Replies
    38
    Views
    1,184

    That is what I do. Never needed a puller.

    That is what I do. Never needed a puller.
  21. Replies
    34
    Views
    993

    Oh come on now, they are not really that hard to...

    Oh come on now, they are not really that hard to fix. Just need to take your time.

    I have not had a big problem with service on mini's.
  22. Replies
    34
    Views
    993

    Thanks Jim, I could not remember the name on...

    Thanks Jim,

    I could not remember the name on the control. There are probably others as well.
  23. Replies
    34
    Views
    993

    The mini is Mitsubishi Not sure of the...

    The mini is Mitsubishi

    Not sure of the controller. But it looked pretty specialized for that purpose.
  24. Replies
    34
    Views
    993

    Where does he say this is for refrigeration? I...

    Where does he say this is for refrigeration?

    I gave a customer that has a mini split for a walk in cooler. Keeps 34 degrees just fine. Has an added controller to make it work.
  25. Replies
    8
    Views
    406

    What I have to tell my customers is, "Forget the...

    What I have to tell my customers is, "Forget the temperatures that the thermostat is displaying, set it where you feel comfortable." The temperature display means nothing.

    Here are a few wild...
  26. Replies
    23
    Views
    860

    Are you able to catch it in the act of tripping?...

    Are you able to catch it in the act of tripping?

    Does it trip when the compressor tries to com on or is it after a long run time?

    I was at a unit years ago with a similar issue. I could not...
  27. Replies
    30
    Views
    868

    Of Course.

    Of Course.
  28. Is this a big box store thermostat. If so throw...

    Is this a big box store thermostat. If so throw it out and get a real one.
  29. Replies
    30
    Views
    868

    What is your TESP? Just had on like that. Evap...

    What is your TESP?

    Just had on like that. Evap coil plugged solid with dog hair on top od oil furnace. Big pain.
  30. Replies
    28
    Views
    646

    Some of the Trane units I have worked on had some...

    Some of the Trane units I have worked on had some sort of filter (about 1/4 the size of a filter dryer). I think it was just a filter.
  31. Replies
    28
    Views
    646

    I have seen this as well. Normally in the side...

    I have seen this as well. Normally in the side panel where the revering valve is.
  32. Replies
    5
    Views
    335

    You will get more condensation once your system...

    You will get more condensation once your system sees longer run time.
  33. Thanks Jacob, Makes sense now. Those places...

    Thanks Jacob,

    Makes sense now.

    Those places must be really leaky.

    I have put in many with no "Extra Low Temp Heating" (I do Fujitsu) in an area where the low is 8 degrees and have never had...
  34. Jacob, I have been curious why in your...

    Jacob,

    I have been curious why in your environment you are putting in Hyper-Heat systems.

    Does it really get that cold where you are to require that extra heating capacity?

    Just curious.
  35. Replies
    4
    Views
    445

    Check your gaskets. Last time I had a similar...

    Check your gaskets.

    Last time I had a similar issue to yours, one og the rubber gaskets fell out of the hoses.

    What a relief to find that, it was driving me nuts.
  36. Thread: Tub-o-towels

    by joemach
    Replies
    15
    Views
    749

    Thanks corny. I will check it out.

    Thanks corny.

    I will check it out.
  37. Thread: Tub-o-towels

    by joemach
    Replies
    15
    Views
    749

    Have not seem them around these parts. But I may...

    Have not seem them around these parts. But I may start to look harder.

    One thing about Scrubs is they do not like freezing weather. They turn into cardboard, useless.
  38. Replies
    11
    Views
    459

    Only if they know what they are doing.

    Only if they know what they are doing.
  39. Replies
    25
    Views
    1,269

    I can get most equipment at my local distributors...

    I can get most equipment at my local distributors cheaper than the online stores. I would prefer to pay a little more to buy locally. I like to see their smiling faces.

    Doesn't your distributor...
  40. Replies
    19
    Views
    565

    I have never had an issue with an "N" coil. Have...

    I have never had an issue with an "N" coil. Have dozens running with no leaks over the past 10 years.
  41. Replies
    53
    Views
    2,214

    I would not put a mini-split in a greasy...

    I would not put a mini-split in a greasy environment.
  42. You have 2 stories to your house. You need 2...

    You have 2 stories to your house. You need 2 separate systems.

    That is the best and most economical solution.

    With 2 floors you have 2 separate environments.
  43. This is what I use......

    This is what I use......
  44. Thread: Recovery tanks

    by joemach
    Replies
    37
    Views
    1,509

    We get paid for clean recovered refrigerant. Just...

    We get paid for clean recovered refrigerant. Just needs to be all the same type in each tank. May $1 or so a lb.
  45. Replies
    19
    Views
    758

    I wouldn't work without one on the truck. Saved...

    I wouldn't work without one on the truck. Saved my but a few times. Had one for years now.

    On new installs I use combustion gas leak detector and soapy bubbles, just to make sure.

    Call me...
  46. Replies
    19
    Views
    758

    Couldn't you just use a combustion gas leak...

    Couldn't you just use a combustion gas leak detector?

    I know... another tool, but not 5 bills.
  47. Replies
    4
    Views
    427

    I think you really need to find out what is...

    I think you really need to find out what is killing those boards. Is it surge, over voltage or even salt from the ocean.

    See if you can find the manufacturer's rep that handles that area of the...
  48. Replies
    26
    Views
    762

    I think garyed gave him the answer he was looking...

    I think garyed gave him the answer he was looking for.

    More on the complex site than simple.
  49. Replies
    39
    Views
    1,654

    I had a similar problem with a Bryant. Check to...

    I had a similar problem with a Bryant. Check to make sure that the igniter is in the path of the gas when the valve opens. I had to bend it slightly so the gas hit the hot HSI.
  50. That is a really cool way of getting proper...

    That is a really cool way of getting proper combustion. I have had difficulty at times with gas furnaces getting the combustion levels I want to see and no way to adjust them.

    Very Cool indeed.