Search:

Type: Posts; User: acguytx

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds.

  1. true New Construction its the architect they...

    true New Construction its the architect they typically put that in the mechanical plans and most of the time show the load as well as duct design and equipment they chose that can meet the load...
  2. I dont know many load calcs that has an indoor DB...

    I dont know many load calcs that has an indoor DB of 68.. it always possible but never guaranteed, given they are in Idaho should be able to do that but no real systems are designed at that temp and...
  3. i dont see a filter base or a base of some sort...

    i dont see a filter base or a base of some sort to get that up off floor for better drainage an a filter base would have been standard here.. thats just sitting on the floor seems a bit of cost...
  4. thats not code everywhere, we tape ours to the SL...

    thats not code everywhere, we tape ours to the SL armaflex until it goes into housing..its nice touch for sure but not code or standard practice around here..for sure they should have taped/and or...
  5. Truck lol you mean the ones left in my office hmm...

    Truck lol you mean the ones left in my office hmm id say the Testo 417 Large Vane Anemometer. Air flow testing gets the least use...dont judge me..
  6. Replies
    61
    Views
    2,705

    Im sorry drive them all, Dodge is the Walmart of...

    Im sorry drive them all, Dodge is the Walmart of trucks... Toyota is pushing both Ford and Chevy i own and FJ its been flawless since 2011 but no way YOUR Mechanics say that and are correct, when my...
  7. Replies
    61
    Views
    2,705

    Look at it this way Ford never used the Bailout,...

    Look at it this way Ford never used the Bailout, chevy/GM used it twice..Ford sales will never be hurting enough to do so..:) They dont need affirmation but snowflake Chevy/GM Owners who will always...
  8. Replies
    61
    Views
    2,705

    Pfft...pshh my 2015 F350 4X4 with locking...

    Pfft...pshh my 2015 F350 4X4 with locking differentials Diesel will drag yo chevy anyday, it may use $300 worth of gas to do so but it would for sure win a tug of war..:bsing: :hijacked:
  9. Replies
    61
    Views
    2,705

    one could only hope lol:bsing: I agree always...

    one could only hope lol:bsing:

    I agree always a learning curve and change is tough for all of us..no one way is the correct way..

    I can see both sides of the argument, I use it myself in my...
  10. Replies
    61
    Views
    2,705

    ok both of you stop lol you both sound equally...

    ok both of you stop lol you both sound equally snobbish.. you kknw there are really good techs that utilize these new tools to be more efficient, take snaphots, notes, and take a whole house...
  11. Replies
    109
    Views
    11,151

    never heard of it but the meter costs in the same...

    never heard of it but the meter costs in the same price range as the 550 but i dont see BT features, an APP, and support from the designers in real time...

    all tools have pros and Cons but IMO...
  12. Replies
    133
    Views
    7,535

    i didnt read all the responses and feedback but...

    i didnt read all the responses and feedback but this being UNDER armaflex and no proof on where and when it happened, blaming the last guy would be reckless and hard to prove..its shame but when did...
  13. Replies
    109
    Views
    11,151

    Ive been finally using the 550 with MQ and...

    Ive been finally using the 550 with MQ and Iconnect etc and what i dont know is how are we using the output Data for PF and what not as a tool to tell our customer what? what does the PF do? are we...
  14. Replies
    61
    Views
    2,705

    i have been using mine for years and they still...

    i have been using mine for years and they still work, i switched to the MQ app but i use the same set you do that are much older and combined with 2 FP Temp clamps they work normally..they did just...
  15. Replies
    7
    Views
    39,949

    this really isnt wall of shame material but we...

    this really isnt wall of shame material but we get your point lol we do this more in attics per code because of the temp differentials but closets are rarely much different then home ambient..also a...
  16. Replies
    20
    Views
    2,842

    Best vibration isolation collar EVER!! LOL

    Best vibration isolation collar EVER!! LOL
  17. Thread: Vacuum Tree

    by acguytx
    Replies
    96
    Views
    4,146

    i want data i might buy 30% faster but the Tree...

    i want data i might buy 30% faster but the Tree itself is restrictive in way and the LL being 1/3 diameter itself , i can see Faster but twice as fast, well ill need some proof..:)):det::cheers:
  18. Thread: Vacuum Tree

    by acguytx
    Replies
    96
    Views
    4,146

    i put it on the Liquid side while pulling from...

    i put it on the Liquid side while pulling from the suction..
  19. Thread: Vacuum Tree

    by acguytx
    Replies
    96
    Views
    4,146

    um I DO not USE MY MANIFOLD..did you not read my...

    um I DO not USE MY MANIFOLD..did you not read my post, i use a direct hose from vac to core remover to suction line and another core remover on LL with Micron gauge on it..
  20. Thread: Vacuum Tree

    by acguytx
    Replies
    96
    Views
    4,146

    my set up up to now has been 3/8 to 1/4 hose...

    my set up up to now has been 3/8 to 1/4 hose attached to my Vac on one end and to the suction side with core tool, then core tool on the liquid port of condenser with the Micron gauge on it..works...
  21. yup i agree this was the best thing Testo has...

    yup i agree this was the best thing Testo has ever made, ive used mine for like 5plus years now with zero issues..its small pocket size light and easy to use..
  22. Replies
    8
    Views
    778

    i have a 417 not sure what the 416 is..

    i have a 417 not sure what the 416 is..
  23. Replies
    20
    Views
    690

    just use an External Backup Hard drive like 1 TB...

    just use an External Backup Hard drive like 1 TB WD Elements and a free backup program like EaseUS Todos and do full backup the first time and Incremental backups scheduled once week or so..

    this...
  24. Replies
    101
    Views
    3,247

    happened to me a few times, you pull permit for...

    happened to me a few times, you pull permit for ONE contracted job and all of a sudden you own the rest of the system, its ridiculous. the Inspectors are taking advantage and misinterpreting the...
  25. Replies
    101
    Views
    3,247

    not true registering in every city around here is...

    not true registering in every city around here is around 200 bucks , if it were a state or county thing to registers once, it would be different there are 100s of citys within 50miles with all their...
  26. Replies
    127
    Views
    4,165

    they all want super professional work done 100%...

    they all want super professional work done 100% correct but pay like it was put in by a fly by night with taillight warranty..

    Kram theres happy Medium, some professional companys charge more...
  27. Replies
    14
    Views
    2,716

    OMFG..right buyer beware deal isnt always a deal...

    OMFG..right buyer beware deal isnt always a deal :))
  28. Replies
    88
    Views
    1,861

    IM all for Pro Choice but this is ridiculous, how...

    IM all for Pro Choice but this is ridiculous, how did this get passed would be my concern...someone put this buried into a bunch of other bulls and slipped it by, i cant see this standing up for too...
  29. Replies
    20
    Views
    3,705

    wow is the LP or NG? thats the worst thing ive...

    wow is the LP or NG? thats the worst thing ive ever seen..
  30. Replies
    7
    Views
    884

    what do you mean true power clamp? there are many...

    what do you mean true power clamp? there are many with BT capability but none work at the moment with MQ, they do have their own Apps..
  31. Replies
    36
    Views
    19,247

    what junky about them other then you get what you...

    what junky about them other then you get what you pay for?
  32. Replies
    19
    Views
    1,413

    customer relation in what aspects, scheduling????

    customer relation in what aspects, scheduling????
  33. Replies
    36
    Views
    19,247

    yes old threads wake up better then starting anew...

    yes old threads wake up better then starting anew one...I found some Digimon SE 8 for $99 with the K temps etc on sale..

    are they worth it to keep as backup\s on older quick checks, maintenance...
  34. Thread: No words

    by acguytx
    Replies
    20
    Views
    4,455

    but dont those pumps already have an internal...

    but dont those pumps already have an internal overflow switch? all the ones ive seen do , whomever pout that on was unaware and well cant be professional :)
  35. Replies
    19
    Views
    1,413

    why couldnt you utilize the Invoicing features on...

    why couldnt you utilize the Invoicing features on Quickbooks? what is wrong with it?
  36. Replies
    19
    Views
    1,413

    Ive been using QBs PC for many years and it does...

    Ive been using QBs PC for many years and it does the job of entering invoices, credit card expenditures and my Banking etc , i use a CPA for the bigger stuff and send him my QB file at years end to...
  37. Replies
    19
    Views
    3,173

    not true the AS/TRane distributors here will NOT...

    not true the AS/TRane distributors here will NOT sell to anyone without and account...period end of story.you can walk up and buy with cash to goodman all the time..not sure if they check licneses...
  38. Replies
    19
    Views
    3,173

    i guess they never heard of mini-split

    i guess they never heard of mini-split
  39. Replies
    24
    Views
    3,408

    Im good at balancing over beams and walking in...

    Im good at balancing over beams and walking in attics here in TX as 60-70% of units are in attics..

    its been in use more then the allowable 60 days to register, not sure if they did it or not, yes...
  40. Replies
    24
    Views
    3,408

    your opinion but i had to take apart and existing...

    your opinion but i had to take apart and existing unit and put it back and wasn't looking for perfection in the aesthetics, its an attic job and a redo and it 100X better then it was as it is also...
  41. Replies
    24
    Views
    3,408

    no one will see once i put the armaflex on nit :))

    no one will see once i put the armaflex on nit :))
  42. Replies
    24
    Views
    3,408

    that was the before pictures, i flipped the...

    that was the before pictures, i flipped the entire air handler and then flipped the coil so it faced horizontal right and can be accessed from service platform..then took breaker section from heat...
  43. Replies
    24
    Views
    3,408

    when you are redoing someone elses mess and...

    when you are redoing someone elses mess and theres second system also tieing into drians with limited slope and the aux pan close, its how it was done.. PVC is cheap..:) it will drain fine
  44. Replies
    24
    Views
    3,408

    Good eyes LOL but yes and no..im coming back to...

    Good eyes LOL but yes and no..im coming back to check the ac and charge in spring. ill recheck drains and cover once im finished and pookie but wanted to be sure it all right before i lock it...
  45. Replies
    24
    Views
    3,408

    sub standard, not to code , and didn't pull...

    sub standard, not to code , and didn't pull permit nor came back to fix it. in small claims the installing company would lose, not sure how much because legally if you do work without permit you are...
  46. Replies
    24
    Views
    3,408

    not sure what you meant by drives, But yes...

    not sure what you meant by drives,

    But yes the only thing they did correct was tape before mastic which is code so a sharp knife open it up and i peeled it all off :)

    I got it mostly all...
  47. Replies
    27
    Views
    4,941

    this the other day very similar, sometimes i...

    this the other day very similar, sometimes i guess you got to what you got to do, this one was leaking so more bad..806023
  48. Replies
    9
    Views
    2,051

    other than no tape or pookie to make doubly no...

    other than no tape or pookie to make doubly no leakage into supply that very creative LOL im a little impressed, not wall of shame to me :))
  49. Replies
    24
    Views
    3,408

    this might count as shameful install

    HMM wall of shame can you see any issues? customer says its not heating correctly and cooling also seems to have an issue, this is what poor install looks like.

    Lets list the obvious from a 6...
  50. Replies
    72
    Views
    5,118

    Amrad basic and the Turbos..

    Amrad basic and the Turbos..
Results 1 to 50 of 1000