  1. 200K is huge. Best to get an accurate manual “J”...

    200K is huge. Best to get an accurate manual “J” done 1st.
    Rural Pa, can you troubleshoot and fix when this H E heater goes down? That’s the price you pay for high efficiency more crap to break.
  2. The issue is When the furnace blower fails...

    The issue is When the furnace blower fails everything stops!

    Generally speaking 15 years is a good life for equipment. Properly installed and maintained it could have 5 - 10 more good years,...
  3. Amp readings would be helpful

    Amp readings would be helpful
  4. Who services the equipment at your house? Get...

    Who services the equipment at your house? Get them to inspect the equipment, a home inspector is not a HVAC Tech!
  5. Anything’s possible. Nothing you can do

    Anything’s possible.

    Nothing you can do
  6. Personally Swap the 5-Ton for a 4-Ton

    Personally
    Swap the 5-Ton for a 4-Ton
  7. Replies
    18
    Views
    326

    Reviews an central HVAC are worthless. The...

    Reviews an central HVAC are worthless. The installing contractor makes or breaks the equipment.
  8. 2 stories 2 systems Short on funds....... 1...

    2 stories
    2 systems

    Short on funds....... 1 system for the 2 Nd floor. Do the 1 st next year.
  9. High head shouldn’t trip the breaker!

    High head shouldn’t trip the breaker!
  10. Replies
    4
    Views
    262

    I GUESS 1-Ton

    I GUESS 1-Ton
  11. Replies
    24
    Views
    579

    1 1/2 - 2 may be more then enough

    1 1/2 - 2 may be more then enough
  12. If you can’t get below 1000 your screwed!

    If you can’t get below 1000 your screwed!
  13. Replies
    24
    Views
    579

    You can’t size by sq ft. That same sq ft exposed...

    You can’t size by sq ft. That same sq ft exposed on all 4 sides is different then one with 2 outside walls.

    Nothing above, below?
  14. and is this when the issues began? You stated...

    and is this when the issues began?

    You stated only 3000 microns so Im confused
  15. The entire "System" ?

    The entire "System" ?
  16. You've got 60KG of contaminated refrigerant! ...

    You've got 60KG of contaminated refrigerant!

    That has to be recovered and cycled thru filter driers. Also the oil in the compressor needs to be changed at least once if not twice!
  17. Why are these shut off?

    Why are these shut off?
  18. You've run it so moisture / water is everywhere!...

    You've run it so moisture / water is everywhere!

    Word of caution, keep an eye on the pump oil. once it begins to get cloudy change it. If it gets cloudy quickly say 10 mins of less you've got a...
  19. Thread: Union gig

    by pecmsg
    Replies
    5
    Views
    354

    Depends. Easiest way is to find a union shop...

    Depends. Easiest way is to find a union shop that's hiring. After X amount of days you get in. Applying to the union directly is for there apprenticeship program. The past schooling may or may not be...
  20. Glad I bought a Fujitsu :grin2:

    Glad I bought a Fujitsu :grin2:
  21. Start all over again! recover the charge ...

    Start all over again!

    recover the charge

    Pull a vacuum 1500 - 1000
    Break with N2

    Pull again 1500 - 1000
    Break with N2
  22. Replies
    24
    Views
    579

    This condo Units above, below, left, right side?...

    This condo
    Units above, below, left, right side?

    Sounds like the last guy is more concerned with getting it right then making a sale!
  23. Big difference between Triple evacuation and...

    Big difference between Triple evacuation and Proper evacuation.
  24. Replies
    5
    Views
    169

    I've got to see this!

    I've got to see this!
  25. Replies
    47
    Views
    956

    No Vapor Barrier No Good!!!

    No Vapor Barrier

    No Good!!!
  26. Properly installed Insulation with a vapor barrier

    Properly installed Insulation with a vapor barrier
  27. Replies
    12
    Views
    276

    Ill agree 2 stories 2 systems but there's no way...

    Ill agree 2 stories 2 systems but there's no way in hell you need 6-Tons!
  28. Replies
    28
    Views
    725

    We need Information!!! All I know is your...

    We need Information!!!

    All I know is your working on a Rack system

    Reread Techman Terrys questions and give us some information

    What is a high temp case?
    What refrigerant?
    What is a drop...
  29. That is one of the major advantages of the BOSCH...

    That is one of the major advantages of the BOSCH system, 2 condensing units replace 8 condensing units giving us the ability to really dial it in!
  30. Replies
    58
    Views
    1,039

    Figures! We never get that much room and clean...

    Figures! We never get that much room and clean floors!
  31. So what killed the pump?

    So what killed the pump?
  32. Dont get me wrong theres ways around that but it...

    Dont get me wrong theres ways around that but it involves more controls and $
  33. Heat pumps dont like 70° ambient heat mode!

    Heat pumps dont like 70° ambient heat mode!
  34. Actually in rush can be 2 - 3 times LRA for the...

    Actually in rush can be 2 - 3 times LRA for the 1st millisecond then drop to LRA then drop as the stator begins to turn. I had a peak amp meter once, is was interesting to see how high inrush can be.
  35. Your not going to be able to start that 3-Ton...

    Your not going to be able to start that 3-Ton unit on the generator! Small inverter units can BUT are much more sensitive to changes in voltage and Hz so will probably shut down on a safety and...
  36. Replies
    17
    Views
    290

    For someone that knows yes.

    For someone that knows yes.
  37. Another thought How are you going to start if...

    Another thought How are you going to start if that box is 70 +°? Heat pumps dont like hot pull downs!
  38. OK You put the condenser in the Walk In box,...

    OK

    You put the condenser in the Walk In box, fire it up, it pulls down begins to frost and ice over. Time for defrost Woosh

    What's going to happen to the condensate
    What's going to happen to...
  39. Replies
    8
    Views
    326

    Now that luck.........You managed to find a Home...

    Now that luck.........You managed to find a Home inspector that actually knows what he looking at!:cheers:
  40. Replies
    17
    Views
    290

    For a DIY is there a difference?

    For a DIY is there a difference?
  41. We all have experience with this...

    We all have experience with this valve.................Every damn one is different!
  42. Replies
    5
    Views
    622

    If I was still in the trade and could use it Not...

    If I was still in the trade and could use it Not an issue. Retired 3K goes towards the boat!

    Trade school and take the writeoff of list price!
  43. Not being rude just being honest! Dont like it...

    Not being rude just being honest! Dont like it tough

    You stated You were trying to save $ Not spent 6K!

    There's a reason we get what we get and a reason we wont deal with someone that believes...
  44. Replies
    839
    Views
    22,772

    I did twice that during heart surgery and I...

    I did twice that during heart surgery and I wouldn't recommend that either. Now 13 days in the hospital to quit smoking, well whatever works!
  45. 56 Db 66 Db are low #'s! Your not going to get...

    56 Db 66 Db are low #'s!

    Your not going to get much lower!
  46. Replies
    29
    Views
    1,157

    Hay Wrong is Wrong!

    Hay

    Wrong is Wrong!
  47. Replies
    29
    Views
    1,157

    NEC Requires 36” clearance for service. This...

    NEC Requires 36” clearance for service. This includes condensers.
  48. Replies
    29
    Views
    1,157

    Those disconnects don’t meet the 36” clearance...

    Those disconnects don’t meet the 36” clearance minimum
  49. Replies
    47
    Views
    956

    That outdoor safety drain MUST be in a noticeable...

    That outdoor safety drain MUST be in a noticeable location so your sister is aware there’s issues.

    I’d still want a 3rd safety hockey puck that shuts down the unit as a final back up!
  50. Replies
    47
    Views
    956

    Is that a ADP Coil? Thought they had a tan cabinet

    Is that a ADP Coil? Thought they had a tan cabinet