Search:

Type: Posts; User: orion242

Page 1 of 20 1 2 3 4

Search: Search took 0.11 seconds.

  1. Thread: NEWS

    by orion242
    Replies
    5
    Views
    297

    "It is kind of like seeing your two best friends...

    "It is kind of like seeing your two best friends get married....."

    LMAO!
  2. Replies
    45
    Views
    6,206

    The general public isn't burning iphone or...

    The general public isn't burning iphone or ianything in the streets yet. Never mind the 'rare' cost oriented customer...

    Make no mistake. I'm not shilling, even supporting this product. The...
  3. Coming into that from the outside, I would switch...

    Coming into that from the outside, I would switch whatever you can to BACnet and just save alot of BS. The ecos work with it, no issue. Setup your logs and alarms in Tridium and forget about the...
  4. Replies
    12
    Views
    368

    OMG. The last two NAEs I ran into with directly...

    OMG. The last two NAEs I ran into with directly connected devices was beyond stupid slow.

    Add another protocol to it and more devices? ok.

    Add another handful of BACnet devices and then...
  5. Replies
    45
    Views
    6,206

    Guygood, You could have just read this thread...

    Guygood,

    You could have just read this thread and would have noticed we deduced this in short order when someone asked about them.



    I have to wonder what ones life looks like without ever...
  6. Replies
    12
    Views
    368

    Twenty first century calling 1990s...getting...

    Twenty first century calling 1990s...getting pretty painful to add a device and there's a flock of scavengers in the air? lol.
  7. https://www.youtube.com/watch?v=1Y5VEpMDsWc

    https://www.youtube.com/watch?v=1Y5VEpMDsWc
  8. Replies
    6
    Views
    500

    The links to the ON/OFF times are to the sun...

    The links to the ON/OFF times are to the sun position block sunrise/sunset times. LightsOn/LightsOff are just for gfx display so the owner can see when its going to happen. EnableSignLights is...
  9. Replies
    2
    Views
    254

    BACnet network numbers would be the same in this...

    BACnet network numbers would be the same in this setup since they are on the same network segment.

    They need vaild MACs that are unique.

    And turn off routing since they cannot be on the same...
  10. If your at 90%+ busy, I wouldn't be changing your...

    If your at 90%+ busy, I wouldn't be changing your tuning polices to write more often. Its going to bog down even more and get worse.

    Would try and get that time lower. Increase the poll rates or...
  11. Would be trying different profiles under your...

    Would be trying different profiles under your user setup. Guessing whatever you currently have setup isn't compatible.
  12. You can only do this on engineering copies. Your...

    You can only do this on engineering copies. Your not transferring licenses on Jaces / customer installs last I checked.

    Far as I know, any brand using Niagara has the option to associate a niag...
  13. Pretty sure if your expired, you can still fetch...

    Pretty sure if your expired, you can still fetch a new license and it will have whatever was current at the point it expired.
  14. Expiration should be right on the first line of...

    Expiration should be right on the first line of your license file. Right at the end.

    <license vendor="Tridium" expiration="never" hostId="Qnx-TITAN-8C26-4D6B-F5E9-XXXX" serialNumber="XXXXX"...
  15. Replies
    6
    Views
    274

    If its already pushed up, you probably have an...

    If its already pushed up, you probably have an Easter egg hunt on your hands.
  16. Look for date codes on the ICs / PCB. ...

    Look for date codes on the ICs / PCB.

    Typically they are 4 digits YYWW, where YY is the two digit year and WW is the week of the year. IC dates may not be a great indicator, but in many cases...
  17. Jaces use a Niagara connection off your...

    Jaces use a Niagara connection off your supervisor license, points over the Niag network do not count against your global points.

    BACnet, Modbus, etc points on any other driver pretty much is what...
  18. Replies
    6
    Views
    274

    More RAM to the VM doesn't mean the javavm...

    More RAM to the VM doesn't mean the javavm running Niagara will use more.

    You need to edit a config file in your Niagara install. That many Jaces, the stock max may not be enough. Don't have my...
  19. View Post

    <feature name="N2JCI" expiration="never" history.limit="none" point.limit="none" schedule.limit="none" device.limit="none"/>

    Doesn't appear to be limited on the N4 FX Jaces.
  20. Replies
    37
    Views
    17,021

    Make sure you have a valid DNS server setup in...

    Make sure you have a valid DNS server setup in your TCP/IP settings.
  21. Replies
    19
    Views
    1,403

    Its rare I can mix these turds with other devices...

    Its rare I can mix these turds with other devices and have anything considered reliable. Even then they may require reset at times.

    Bottom of the barrel garbage devices IMO. Right next to VRF...
  22. These Trend devices? If so, what? IQ1,2,3,4,...

    These Trend devices? If so, what? IQ1,2,3,4, IQL, IQe?




    What's the polling stats look like, busy time? That driver isn't one I'm too fond of and avoid it unless its absolutely necessary. ...
  23. Would have to look at the last project I did with...

    Would have to look at the last project I did with NAEs for the exact count.

    I had two MS-NAE4510-2 that were dog slow to the point the customer couldn't use the system. Replaced both with a...
  24. Replies
    2
    Views
    200

    If you have a supervisor, creating links this way...

    If you have a supervisor, creating links this way isn't the way to go about it.

    You realize your going to be prompted to log in each time you bounce between Jaces right?
  25. The later and please have the cleaning crew bag...

    The later and please have the cleaning crew bag it for carry out.

    I have a sales person that wants it deposited in their car.
  26. SMS, there is a wad of devices out there similar...

    SMS, there is a wad of devices out there similar to this. Input closes, it sends a per-defined SMS over cellular.

    https://www.seltec.co.uk/products/details/9662.html
  27. Peplink cell router or similar that can fail over...

    Peplink cell router or similar that can fail over to cell connection automatically if the main connection drops.

    Sensaphone dialer and an POTS line to call out a list of numbers with general alarm...
  28. Replies
    3
    Views
    244

    Would raise this on niag central. Haven't done...

    Would raise this on niag central.

    Haven't done much with templates yet, but can see this is a big downer on that idea.

    In a perfect world, its not stupid gateways that present as a bucket of...
  29. Indeed. What the VAVs don't need will flow...

    Indeed. What the VAVs don't need will flow through the bypass. So airflow on the unit will be roughly the same. Under low loads, if cooling is enabled it most of it may go from supply directly...
  30. Try just tridium or niagara before you mess with...

    Try just tridium or niagara before you mess with that hassle.
  31. Replies
    5
    Views
    442

    Something sure smells off with your comms if this...

    Something sure smells off with your comms if this is happening. Being its a VRV system, its not a surprise.

    If you look at the property sheet of one of these faulted points, what's the error in...
  32. Would poke around https://www.avrfreaks.net/ for...

    Would poke around https://www.avrfreaks.net/ for questions on AVR Studio.
  33. Replies
    16
    Views
    862

    Sounds like your outfit has a plan that'a 180...

    Sounds like your outfit has a plan that'a 180 degrees apart that city I looked at.

    Those jokers where blowing seven figures every three years to tread water, if not go backwards. That contract...
  34. Replies
    16
    Views
    862

    Good call. Something that size, you either need...

    Good call. Something that size, you either need to go your route or have a solid set of naming, addressing, sequence, etc standards in your spec. If not, its going to turn into a massive pile of...
  35. Replies
    16
    Views
    862

    Don't stumble on enough sites with a super setup...

    Don't stumble on enough sites with a super setup to really call it. Most I find are an epic fail for many reasons. I do run into some with a super, but that's not common and its normally an equal...
  36. These down and dirty systems are very common and...

    These down and dirty systems are very common and they can work reasonable well.

    You want control the bypass as described here. The supply air temp also needs attention. You need reasonable...
  37. Replies
    0
    Views
    146

    SmartStack System

    Anyone else run into this system?

    https://www.measuredap.com/
  38. Replies
    16
    Views
    862

    The main benefits are the central management of...

    The main benefits are the central management of everything.

    If you have something like a collage campus with a wad of jaces out there...

    User management
    Central alarm handling & routing
    Daily...
  39. Replies
    16
    Views
    862

    Lol ran into that as well. Found sites with it...

    Lol ran into that as well.

    Found sites with it installed, has connections to the Jaces but its not doing anything. Everything is coming straight out of the Jaces, nothing is synced or coordinated...
  40. Replies
    16
    Views
    862

    Lol. Its probably more to do with the sites...

    Lol.

    Its probably more to do with the sites you run into.

    Typically when I see a setup like this, its a customer that is chasing whoever is a nickel cheaper.

    No shortage of jokers that cut...
  41. Replies
    13
    Views
    1,001

    So where does the random customer / contractor...

    So where does the random customer / contractor get those jar files? HW have a public download link?



    Little different than spudder then. Its using custom blocks that only work within that...
  42. Replies
    25
    Views
    1,206

    Now that I think about it more, if we are talking...

    Now that I think about it more, if we are talking all PTO...

    Would have to add up my sick time, paid holidays, and normal vaca time. Prob not far off from 30 days. The miserable state I work in,...
  43. Replies
    7
    Views
    422

    Your options are pretty limited. Would look in...

    Your options are pretty limited. Would look in whatever gateways they offer for those and expect little better than cutting mains to it.

    That's some fairly expensive gear in a space to half a$$...
  44. So are these controllers sun tracking? What...

    So are these controllers sun tracking? What exactly are the BACnet devices doing out in the array?

    Thermal array? This the type that uses a field of mirrors to concentrate the sun in a single...
  45. Replies
    25
    Views
    1,206

    Agree pay vs PTO. That said, I haven't ever...

    Agree pay vs PTO. That said, I haven't ever worked at a shop that prevented me from time off, be it PTO or unpaid. Don't normally take time off in the peak of the work season, but never have been...
  46. Replies
    2
    Views
    272

    Not knowing anything about these devices, I would...

    Not knowing anything about these devices, I would make sure the time is correct between them.

    Depending on the auth protocol, there are some that fail if the clocks are to far out of sync. Given...
  47. Replies
    25
    Views
    1,206

    CA, you work like a dog to rent your tiny home...

    CA, you work like a dog to rent your tiny home unless your a native from 20+ yrs back. Welcome to CA. If that area is your thing, more power to you. If not, why stick around?

    Changed locations...
  48. Find it funny that any vendor offering BACnet...

    Find it funny that any vendor offering BACnet devices, doesn't include integrated discovery tools that can discover, read / write any object in any device that support such action.

    I know some of...
  49. Replies
    25
    Views
    1,206

    Anything to cover lost work days due to power...

    Anything to cover lost work days due to power outage lol.

    Smelling $/kwh costs to match $/gal gas cost there in the near future.
  50. Replies
    6
    Views
    443

    Seems like some lazy BS to me. Given the damn...

    Seems like some lazy BS to me. Given the damn thing can take forever, its pretty frustrating if your shuffling things around to get those last few points.

    Almost like they made it so painful in...
Results 1 to 50 of 1000