Search:

Type: Posts; User: Nytefog

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    7
    Views
    533

    i contacted refrigerant finders also. They will...

    i contacted refrigerant finders also. They will actually pick up the refrigerant and pay you cash on the spot. $18 a lbs seems low $540 a cylinder.... I also have a can of r500 but they only want...
  2. Replies
    7
    Views
    533

    What are 30 lbs cylinders of r-12 worth 9/2022? ...

    What are 30 lbs cylinders of r-12 worth 9/2022? I think I still have 5-6 cylinder left from a large purchase back in the late 1980s. $20/cylinders at the time. 10 pallets of r12! Quite a...
  3. Replies
    1
    Views
    270

    Please let me know if you are interested in...

    Please let me know if you are interested in having pictures of the Jobox Storall drawers. I donít want to waste any time if no one in the area is interested in them. I bought the same size drawers...
  4. Replies
    1
    Views
    270

    Jobox Storall Storage Drawers

    Hello,

    I have Jobox Storall Storage drawers for sale. They havw never been used and have been stored in a shipping container.

    (2) StorAllô 13" Tall Heavy-Duty Steel Drawer Storage 12"W x 13"H...
  5. Still using Digicool AK900 and have the older YJ...

    Still using Digicool AK900 and have the older YJ Digicool refrigerant system analyzer. I also still have (4) new Digicool Ak900, and a many new sets of pipe clamp temp probes, as backups because i...
  6. I know this thread is older but I would have...

    I know this thread is older but I would have looked at AEMC 407 Power clamp meter. This clamp meter also has a great inrush reading, they call "true inrush". Their in respones time is 1ms and...
  7. Replies
    1
    Views
    331

    Etech dehum/AC (pool room)

    Does anyone know who currently owns Etech equipment? They make/had made indoor pool room dehumidifiers/AC units. They are more of a commercial grade of equipment.


    I canít seem to find info on...
  8. Replies
    74
    Views
    6,453

    Iíve found the testo 316-4 is the best/most...

    Iíve found the testo 316-4 is the best/most sensitive R410a leak detector. I also use the testo 316-3 for R22. The Inficon Tek-Mate is also great finding R22 leaks. I also have the fieldpiece...
  9. Replies
    2
    Views
    694

    Peerless Purefire Flame Sensor issue

    Hi,

    Iíve been working on Peerless/HTP Pinnacle and Peerless Purefire boilers for the past 10 years. I have maintenance and troubleshooting almost down to a scienceÖor so i thought! I always...
  10. Iíve been using the service manual. The venting...

    Iíve been using the service manual. The venting definitely has some issue. There is a reducer on a 3Ē-2Ē PVC reducer that connects to a 3Ē 45į that then connects to a concentric vent I believe may...
  11. Ducane 92G1UH Inducer collecting condensate

    Hello,

    Iím having a issue with A Ducane m#92G1UH090CP16-55 s#1716b08059 draft inducer filling with condensate.

    Iíve cleaned the trap, the two drain ports on the plastic piece above the inducer...
  12. Replies
    3
    Views
    689

    MRU DM 9600 differential Manometer

    Hey,

    Has anyone had any experience with the MRU DM 9600 Manometer? I was looking for a new differential manometer and ran across MRU manometer.

    https://mru-instruments.com/product/dm-9600/
    ...
  13. Replies
    3
    Views
    593

    Vaillant boiler M# ga92-140 - Manual

    Hello,

    Does anyone have the manual for a Vaillant boiler model# ga92-140?

    The gas valve failed. The on side facing the boiler has been exposed to serious heat and the plastic cover is black...
  14. Replies
    15
    Views
    2,003

    Itís more for customer we have installed new...

    Itís more for customer we have installed new equipment for. They pay 15k for new equipment installation, but donít want to spend money maintaining it. This then can compromising their factory...
  15. Replies
    45
    Views
    4,568

    I use a Megger MIT420 insulation tester for...

    I use a Megger MIT420 insulation tester for compressor short troubleshooting. Carefully!
  16. Replies
    45
    Views
    4,568

    I love AEMC CLAMP METERS WITH TRUE INRUSH...

    I love AEMC CLAMP METERS WITH TRUE INRUSH measurement. The meter takes a measurement every 1 ms when set to inrush measurement. It the fastest brand of meters that Iím aware of that can capture...
  17. Replies
    15
    Views
    2,003

    It get hard to compete with the outfits that...

    It get hard to compete with the outfits that charge <$60 for a PM. You know they are at the customers home for maybe 30 minutes. Changing the filter and humidifier pad, maybe cleaning the flame...
  18. Replies
    15
    Views
    2,003

    I also always performed C.A. at every...

    I also always performed C.A. at every maint/service call. I just wanted to find out if others include it in the price of their PM or have a separate charge for testing. I agree it’s with out a...
  19. Replies
    15
    Views
    2,003

    I myself always perform Combustion Analysis on...

    I myself always perform Combustion Analysis on any furnace/boiler during PMs or repairs. At least ever since I took the NCI class with Jim Davis twice over the past 10 years ago. I wanted to ask...
  20. Replies
    15
    Views
    2,003

    Combustion Analysis and PMís

    Hey,

    Do you guy charge extra fee performing a combustion analysis during furnace PMís?
  21. I’ve accumulated Testo, Fieldpiece, Sporlan and...

    I’ve accumulated Testo, Fieldpiece, Sporlan and Appion smart probes but still prefer my Digicool AK900s. I grabbed three new AK900’s stashed away when I found out they were stopping production. The...
  22. Replies
    16
    Views
    1,498

    I was just curious about these products. Iíve...

    I was just curious about these products. Iíve never used them. Iíve made many flares over the years on mostly refrigeration coolers/freezers, driers, and txv connections but with r410a heat pumps...
  23. Replies
    16
    Views
    1,498

    TPI Flexflair Leak Proof Flare Fittings?

    Hello,

    Anyone have any experience with these TPI Flexflair fittings? I was just curious about them and the durability/reliability.
    ...
  24. Replies
    25
    Views
    3,430

    I agree 100%. Customer attitude plays a large...

    I agree 100%. Customer attitude plays a large part in the final price. Something as simple as offering a bottle of water can make the difference on having that access fee added or not.
  25. Replies
    25
    Views
    3,430

    I agree that base price is for a conventional...

    I agree that base price is for a conventional system with relatively easy/normal access. You never know what you will discover when you get to the job location. Then you have customers that call and...
  26. Replies
    1
    Views
    1,434

    Fieldpiece DR58

    Hello,

    Has anyone got the new Fieldpiece DR58 Leak detector? I got one to replace my SRL8. I wanted to know if you think itís as sensitive as the SRL8. I do like that it doesnít give as many...
  27. Replies
    25
    Views
    3,430

    Use of Ladder Fee/Charge

    Hey,

    How many of you charge for use of ladder during service call? Especially if you need a 8ft+ ladder to access equipment.

    Do any of you also charge difficult access for systems that are a...
  28. Replies
    0
    Views
    367

    Ladder use Charge

    Wrong forum.. sorry
  29. Replies
    3
    Views
    1,671

    Thanks. The negative pressure, taken from...

    Thanks.

    The negative pressure, taken from the condensate trap port where the pressure switch is connected, intermittently drops below -1.5Ē and the pressure switch opens. The condensate trap and...
  30. Replies
    3
    Views
    1,671

    Aire Flo Furnace- AF90MPE075U3 Manuals?

    Hey,

    Iíve been searching for Aire Flo furnace AF90MPE075U3 installation/Service Manual. Does anyone happen to know where I can locate these documents? The LennoxPro app only has the product data...
  31. Replies
    41
    Views
    5,680

    I know that at least the Carrier multizone...

    I know that at least the Carrier multizone Mini-Splits valves in the outdoor units do not close 100% when a zone is not calling for heat. Since the fan runs continuously to monitor return air temp...
  32. Replies
    3
    Views
    1,186

    Thanks You!

    Thanks You!
  33. Replies
    3
    Views
    1,186

    American Standard AUD

    Hello,

    Could anyone be able to give me a part number for a replacement Draft inducer/Combustion blower for American Standard, 2-Stage, 80%

    M# AUD080R936J1
    S#R202LF91G

    I donít have access to...
  34. Thread: Wire crimps

    by Nytefog
    Replies
    35
    Views
    7,916

    If you need a set of crimper for the small open...

    If you need a set of crimper for the small open barrel connectors this Japanese company makes a great set. They are also the company that makes those tools rebranded as Vampliers.

    For as much as...
  35. Thread: Wire crimps

    by Nytefog
    Replies
    35
    Views
    7,916

    You like the German tools like myself! Iím...

    You like the German tools like myself!

    Iím still trying to identify the type of some of the small terminal types on equipment controls that need to be replaced because of severe corrosion issues.
  36. Replies
    24
    Views
    8,224

    The ak900 that they are asking $350 for has been...

    The ak900 that they are asking $350 for has been on eBay for a while now. If your patient you will find brand new ak900, or the UEI branded AK900s, sets for under $200 with clamp temp sensors. Pawn...
  37. Replies
    25
    Views
    5,489

    In New Jersey commercially registered/Insured...

    In New Jersey commercially registered/Insured vehicles ďshall have conspicuously displayed thereonď.

    Sometimes I wish I didnít have any signs on my vehicle. I do get away with parking where I...
  38. Replies
    25
    Views
    5,489

    Our entire fleet got hit a few years ago. They...

    Our entire fleet got hit a few years ago. They go all of the expensive tools. All the Hilti tools, coring bits, recovery machines, vacuum pumps, scales, rigid power theading tools/dies and tripods, ...
  39. Replies
    5
    Views
    2,094

    You could buy/use a decade box. I have a few...

    You could buy/use a decade box. I have a few from IET.
  40. Thread: Wire crimps

    by Nytefog
    Replies
    35
    Views
    7,916

    I like this set I got on amazon Tool Aid SG...

    I like this set I got on amazon

    Tool Aid SG SGT18980 Ratcheting Terminal Crimping Kit (Quick Change with 9 Die Sets)

    And from eBay
    Thomas & Betts T&B ERG4001 Sta-Kon Manual Ratcheting Crimper...
  41. Thread: Appion TEZ8?

    by Nytefog
    Replies
    9
    Views
    2,274

    Do you use the Trublu hoses or Appions?

    Do you use the Trublu hoses or Appions?
  42. Thread: Appion TEZ8?

    by Nytefog
    Replies
    9
    Views
    2,274

    Appion TEZ8?

    Hello,

    I have a chance to get a new Appion TEZ8 vacuum pump to go along with my very old JB platinum 5 CFM and my 8 year old JB platinum 7 CFM JB platinum vacuum pumps. I like the TEZ8s number...
  43. Thread: Amp Clamps

    by Nytefog
    Replies
    31
    Views
    8,593

    AEMC 407 ...

    AEMC 407

    https://www.aemc.com/products/power-analyzers/clampon-meter-407-a

    They have the best inrush capture time of any clamp meter I've had. (Fluke, Amprobe, Redfish, Testo)

    If your lucky...
  44. Replies
    0
    Views
    1,218

    Multi-tip air ac

    I was reading a thread where someone was looking for a snap-in air-Acetylene torch tip, with two tips similar to the captain hook style Oxy-acetylene. I couldn't remember that brand but I finally...
  45. On the scopes probe you can switch between a...

    On the scopes probe you can switch between a camera on the side of the tip (90į) or the on on the end of it.
  46. I got a Wohler VE400 a few months ago. Itís...

    I got a Wohler VE400 a few months ago. Itís replacing my old ridgid seesnake. So far itís been great. Iíve tired two of those bluetooth boroscope camera and they were/are terrible tools. They...
  47. Replies
    9
    Views
    2,328

    New D-TEKģ 3 Refrigerant Leak Detector?

    Has anyone seen this new inficon leak detector? Looks like the stratus that was released last year.
    ...
  48. Acuutrake VPE ultrasonic leak detector Tips?

    Does anyone have any tips for using ultrasonic leak detectors for locating refrigerant leaks?

    Are the Koss headphones that come with the kit worth replacing with another type of headphone?

    I've...
  49. Replies
    4
    Views
    1,713

    ďLennox is they seem to have a bad rap on...

    ďLennox is they seem to have a bad rap on warranty and getting parts.Ē

    Very true statement. I can even remember how many times now they have sent the wrong Repair parts. Evening with the model...
  50. Opps, I did not realize hadn't been in the right...

    Opps, I did not realize hadn't been in the right forum. Thanks foR the heads up.
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4