  1. Replies
    16
    Views
    381

    you can do UPC's that's by mstp. or you can...

    you can do UPC's that's by mstp. or you can use a ccn router which would be an IP connection. I dont know how your system works if that would communicate.

    for the router you need service tool...
  2. his description sounds like a fan coil to me.

    his description sounds like a fan coil to me.
  3. so I understand you correctly. there is a...

    so I understand you correctly. there is a chiller supply and return. boiler supply and return. and they both feed a single coil. Sounds like they are using the 3 way as a flow control to match...
  4. Chillerr123 email me. its in my profile.

    Chillerr123 email me. its in my profile.
  5. IVU tools. which is field assistant, equipment...

    IVU tools. which is field assistant, equipment builder snap viewbuilder and apploader you will need the USB -L kit for connecting.
  6. when I say set up im referring to things like...

    when I say set up im referring to things like mode of control, as in always on, remote, or ccn. or dual chiller set up. resets. I just looked at some sites. they are changeable by the UPC...
  7. are these locked? 811235

    are these locked?


    811235
  8. Are you trying here? 811234

    Are you trying here?
    811234
  9. The carrier software had factory made programs...

    The carrier software had factory made programs for most chillers. I had an old one that it didn't ( comfort link equipped chillers)
    it talks BACnet. I don't keep up with the modbus notes but I...
  10. read document page 23 and 24 811042

    read document page 23 and 24
    811042
  11. Replies
    7
    Views
    324

    Get an ivu and save the headache. it will upload...

    Get an ivu and save the headache. it will upload anything on the ccn. ( need the ccn usb or a ccn router.) and you can make new floor plan graphics if you want
  12. your carrier rep is right as in the rtu open...

    your carrier rep is right as in the rtu open board is locked and we cant change anything with it. thats why you need to add the uc.

    All carrier pic controllers are locked. rtu 1 and 2 wshp vav...
  13. Max has it right with the addressing to see each...

    Max has it right with the addressing to see each zone sensor. What you will need to do is add a opn-uc to the project. The uc can have 10 programs. OR write one program for all 20 rtu.

    Use...
  14. Awesome!! The Ivu, is it a 6.0 or older. You...

    Awesome!!
    The Ivu, is it a 6.0 or older. You can change can address with those

    6.5 and 7 they removed it
  15. Replies
    9
    Views
    535

    the master stat communicates to the relay pack, ...

    the master stat communicates to the relay pack, the relay pack talks to the rtu through normal thermostat connections.
  16. Replies
    28
    Views
    1,311

    I wasn't thinking that was the name of it. Yes...

    I wasn't thinking that was the name of it. Yes that would be helpful along with fan control. Good advice spitz
  17. Replies
    24
    Views
    1,354

    I've only ever had 45 deg. We had a vrf rep do a...

    I've only ever had 45 deg. We had a vrf rep do a class at the office. That's where I actually got the older comment from. Shows how much I have used flare through the years.
    Just looked on...
  18. Replies
    28
    Views
    1,311

    what is a head master and what does it do?

    what is a head master and what does it do?
  19. Replies
    22
    Views
    1,368

    dumb ass but LOL

    dumb ass but LOL
  20. Replies
    10
    Views
    4,221

    for the full document...

    for the full document
    https://www.carrier.com/commercial/en/us/products/chillers-components/air-cooled-chillers/30rap/
  21. Replies
    10
    Views
    4,221

    We have had a lot of power issues from storms. ...

    We have had a lot of power issues from storms. The chillers will run for months then trip on this code during a storm. Its most likely power supply rated.
    Today we had a T051 and another where...
  22. you have to do many oil changes, sporlan water...

    you have to do many oil changes, sporlan water filters and a long slow multil evac vacuum. All depends on if the water ruined the bearings or not.

    We had a site with this issue. Be sure you have...
  23. Replies
    13
    Views
    750

    delay on break yes. delay on make , no

    delay on break yes. delay on make , no
  24. Replies
    22
    Views
    1,368

    I like this guy

    I like this guy
  25. Replies
    28
    Views
    1,743

    which way did you solve it, transformer or relay...

    which way did you solve it, transformer or relay and a 208 coil
  26. Replies
    10
    Views
    685

    Loose connection or high amps.

    Loose connection or high amps.
  27. Replies
    24
    Views
    1,354

    Be sure you have the correct Deg of flare angle. ...

    Be sure you have the correct Deg of flare angle. 410 equipment is 45 deg. Older stuff was 30 deg I believe.
  28. Replies
    28
    Views
    1,311

    he is making a head master set up.

    he is making a head master set up.
  29. Replies
    28
    Views
    1,311

    being your low ambient I'd also install a wind...

    being your low ambient I'd also install a wind baffle along with the controls.

    if I were doing your task I would either modulate the fans at a minimum of 85 deg line temp or 185 psi If its...
  30. Replies
    13
    Views
    750

    carrier doesn't have a fan delay on in cooling,...

    carrier doesn't have a fan delay on in cooling, just heating
  31. Replies
    9
    Views
    535

    That's old Carrier gen 3 stuff. The...

    That's old Carrier gen 3 stuff. The communication is CCN. Id be surprised if the whole system works. only a few pieces are still available.
    Unless you guys have your own VVT system constant...
  32. Replies
    57
    Views
    2,626

    did anyone previously discuss double row coils...

    did anyone previously discuss double row coils and the need to separate them?
  33. Replies
    57
    Views
    2,626

    Remove the lint supply. Sounds like a...

    Remove the lint supply. Sounds like a laundromat. Re-duct the drier exhaust elsewhere.

    Also get micro chanel coils on the next unit change. They clean much easier. Just use a micro channel...
  34. did it work?

    did it work?
  35. Replies
    12
    Views
    1,183

    I havent had to do this yet. I have not attempted...

    I havent had to do this yet. I have not attempted to look it up. Whats the value of the resistor.
  36. move to va and I'll give you a job

    move to va and I'll give you a job
  37. Replies
    12
    Views
    1,183

    when changing compressors in a multi compressor...

    when changing compressors in a multi compressor refrigerant circuit. Be sure to check for acid before replacing just one.
    One burnt compressor creating acid in the process destroys the other two....
  38. this is from the start up manual on the 48LC*B...

    this is from the start up manual on the 48LC*B units.


    810703
  39. yup

    yup
  40. Replies
    5
    Views
    424

    why are you guys referring to the clo. and what...

    why are you guys referring to the clo. and what do you think is causing it to trip
  41. Replies
    5
    Views
    424

    with a 20 sc your defiantly have charge. th 20 sh...

    with a 20 sc your defiantly have charge. th 20 sh shows not enough flow. those txv are adjustable. I would turn the stems out 1 turn and see what happens. you will want to adjust each circuit...
  42. Replies
    33
    Views
    5,598

    ingenuity and thinking on your feet make you a...

    ingenuity and thinking on your feet make you a smart tech. A parts changer would have had to return.
  43. A staging control would be best. no need for two...

    A staging control would be best. no need for two to run if the load doesn't need it. Boilers do like to run longer then shorter. The flue likes it also. Get past the condensing stage.
    A big part...
  44. in the picture that's a bus scan. you need to...

    in the picture that's a bus scan. you need to check the boxes then upload the device. then you can change the address.

    once uploaded you can right click and hit properties or use the search (...
  45. before you do. Tell me about the unit or system...

    before you do. Tell me about the unit or system you are working on. there may be a better way.

    NSTV is what you need but they are over $1000 now i believe. A UPC or ccn router is much better. ...
  46. Max. The rtu open needs a sat and space temp...

    Max. The rtu open needs a sat and space temp input to operate. When you take off the ET you loose space temp. With the et space temp is by a network input

    There is a network space temp input...
  47. rtu opens require 2 things to run, a sat sensor...

    rtu opens require 2 things to run, a sat sensor and mainly a t-55 sensor. if you hook them up it runs. its defaulted to use a t55 sensor. anything other then that it will need field assistant, a...
  48. Replies
    28
    Views
    1,743

    i bet if you check the amps when it pulls in they...

    i bet if you check the amps when it pulls in they are well past a 100 va transformer.
  49. so basically you want to monitor the line voltage...

    so basically you want to monitor the line voltage and trend it? send an alarm if it gets to low?
  50. if you have issues with those translators they...

    if you have issues with those translators they can be replaced with UPC's which with the new driver does modbus. if you can do bacnet IP you can use the CCN router