  1. Replies
    57
    Views
    947

    My favorite thing to use is my portable plasma...

    My favorite thing to use is my portable plasma cutter. The only problem is that for one hole it is too heavy to lug out out to the job, maybe a tad over 50#.
  2. Replies
    9
    Views
    377

    Not the worst I have seen. In the first picture...

    Not the worst I have seen. In the first picture the return looks worse than the supply.

    The worst one I have seen is 20 x 8 supply trunk with a 16 by 8 tapped into the bottom running with the ...
  3. From what I am gathering from your post this is...

    From what I am gathering from your post this is not the proper way to diagnose a TXV. If you think about it on a 90 or 100 degree day that line temp is going to run somewhere over 90 degrees if the...
  4. Don't forget they hid those tag so they are hard...

    Don't forget they hid those tag so they are hard to find.
  5. {To the OP}, see the tag in this picture, there...

    {To the OP}, see the tag in this picture, there is your compressor "code".
  6. It mentions it in the install manual. You remove...

    It mentions it in the install manual. You remove the horizontal pan and then take the top baffle off usually there is a smaller top baffle under. Seems like that top baffle had a diverter under it...
  7. Sad to say but yes it is common that they don't...

    Sad to say but yes it is common that they don't know how to design/build a duct system. From your picture I am going to say the tap is in the vortex current created by the 2 90 fittings that are...
  8. It may be that they are talking using the right...

    It may be that they are talking using the right BTU sized furnace in a 21" cabinet that comes with a 5T blower. The blower can be adjusted "dialed back" to move the air needed for your A/C.
    ...
  9. Replies
    36
    Views
    915

    The more important question is are your line...

    The more important question is are your line sizes correct.

    It sounds like you are reusing an old line set. Lines for old systems may not be correct for the new system.
  10. Replies
    10
    Views
    753

    I should have taken a picture but I got you beat,...

    I should have taken a picture but I got you beat, by over a year. I could dig it out of the dumpster but really don't want to mess with it. An Aprilaire 201 media, I put it in 1/30/19, changed it...
  11. Replies
    10
    Views
    753

    Where is the picture of how clean or dirty the...

    Where is the picture of how clean or dirty the blower and or coil is after filter over fill?
  12. Replies
    51
    Views
    1,692

    My 55 Chevy pickup used to get a few gallons of...

    My 55 Chevy pickup used to get a few gallons of gas, 5 at most as it was only used to haul leaves to the compost center, never had a problem running out of gas. Then one day I took leaves out and...
  13. An easy way for you to tell if it is in cooling...

    An easy way for you to tell if it is in cooling or heating mode is check the outdoor fan. If the air coming off is warmer than surrounding air it is in cooling, if the air is noticeably cooler like...
  14. Replies
    51
    Views
    1,692

    How much gas are we talking. I figure it can’t be...

    How much gas are we talking. I figure it can’t be more than 12 gallon.

    Does the loss seem consistent with time frame?

    If my mind is wondering through the math at 12 gallon in 3 months then it...
  15. Replies
    51
    Views
    1,692

    When all other possiblities have been properly...

    When all other possiblities have been properly discounted the one that's left must be it, or so the saying goes. So the logical conclusion is . . .

    The Twilight zone.
  16. Thread: Fluke 902 FC

    by BNME8EZ
    Replies
    21
    Views
    1,147

    Wait what! Compressor windings are normally...

    Wait what! Compressor windings are normally under 10 ohms. Motor windings under 100 ohms. Mega ohms on a meter as I understand are not the same as a “Megger” which puts voltage on the windings...
  17. Replies
    25
    Views
    496

    The thing is this ain’t my first rodeo. On the 2...

    The thing is this ain’t my first rodeo. On the 2 I learned on, both 410, don’t ever remember it on 22, they ran over 30 minutes and the refrigerant was added slowly. Both of them were over 90 IA. ...
  18. Thread: Fluke 902 FC

    by BNME8EZ
    Replies
    21
    Views
    1,147

    I have been using the 902 for some time and I...

    I have been using the 902 for some time and I just clamp it around the handle on my bag with the leads wrapped through the jaws. It is handy hanging there and it doesn't seem to mind the abuse if...
  19. Replies
    21
    Views
    890

    I'm sure there are still some around these parts...

    I'm sure there are still some around these parts but I haven't seen one in years.

    We used to have interruptible gas systems for commercial where if gas use started to get stressed they would...
  20. Replies
    25
    Views
    496

    Because we are in a hurry. I have done that...

    Because we are in a hurry. I have done that several times and had to go back to fix it.

    You have a hot pull down, the TXV is wide open so you get no SC, so you add refrigerant. SC is still low...
  21. Replies
    25
    Views
    496

    I'm getting somewhere north of 70 SC do you...

    I'm getting somewhere north of 70 SC do you suppose that is a problem?

    Depending on the size of unit 5/16 may be usable. I did a 2 T HP and have not had a problem . . . yet. Tech support was...
  22. Replies
    22
    Views
    560

    140° is low. There have been cases of farmers...

    140° is low. There have been cases of farmers bailing hay before it is dried down properly. It can get hot enough to spontaneously combust, otherwise known as catching fire on it's own, out in a...
  23. Replies
    4
    Views
    655

    Get that system checked quick. The water going...

    Get that system checked quick. The water going out the bottom of the furnace should be going down the drain line. Since it is not going out the drain line if it runs across anything electrical it...
  24. If you guys would quite burning trees out there...

    If you guys would quite burning trees out there it would have a chance to cool down. We burnt the west 1/4 of the state almost and it was warmer here earlier. Now that the fires out it has cooled a...
  25. Sorry, I am missing something. You have a power...

    Sorry, I am missing something. You have a power problem at the outside unit with not getting over 24 V to the compressor but the tech bypassed a breaker to the inside unit and the compressor outside...
  26. Replies
    7
    Views
    354

    You mention upstairs and I am assuming new...

    You mention upstairs and I am assuming new construction IE built less than 30 years ago. You also mention upstairs/downstairs so I am assuming again open stairway.

    Now you said that the new...
  27. Replies
    24
    Views
    875

    I hope I can explain this properly. I can see it...

    I hope I can explain this properly. I can see it in my head but getting it in words on a screen is sometimes a bit different.

    Somewhere in all my years I saw a diagram of what air does as it...
  28. Replies
    24
    Views
    875

    The higher velocity and turbulence maj s sense on...

    The higher velocity and turbulence maj s sense on heat transfer to a point. In GEO systems, ground source, they use smaller tube to increase velocity and turbulence so the water tumbles and more...
  29. All I can tell you is that those electronics...

    All I can tell you is that those electronics don’t play well with others. I tried putting a Trane ecm and board in a WSHP. The blower ran fine, as did the heat pump but I could not get the blower...
  30. Lose the fast stat and get the correct wire...

    Lose the fast stat and get the correct wire bundles to where they need to be and I think your wiring issues will disappear. It will still need to be wired correctly and properly set up but if your...
  31. Replies
    24
    Views
    875

    I disagree with your reasoning, here is why. ...

    I disagree with your reasoning, here is why.

    We are talking temp off a coil on a window unit, fix output BTU capacity. yes it will vary slightly depending on air speed but still be reasonably...
  32. Replies
    8
    Views
    296

    Here is a thought, might be an option and give...

    Here is a thought, might be an option and give you some time to spread out equipment purchases. Stay with oil heat but at air to air heat pumps as the A/C/furnaces fail. When you replace a...
  33. That could be a sign of a crack or hole. I would...

    That could be a sign of a crack or hole. I would think it would have to be a pretty big one for that but it would depend on location. It could also be just a gravity affect where one was pulling in...
  34. Replies
    80
    Views
    1,725

    What I am getting is oversize on equipment and...

    What I am getting is oversize on equipment and possible more air than necessary.

    As had been said new houses are full of moisture, especially if it happened to be wet while the house was open.
    ...
  35. Thread: Shoe Covers

    by BNME8EZ
    Replies
    17
    Views
    558

    I work hard at keeping my shoes clean so the only...

    I work hard at keeping my shoes clean so the only place I really wear them is if the house is that dirty that I don't want to track outside.
  36. Replies
    35
    Views
    940

    Looks like they may have the blower set up to...

    Looks like they may have the blower set up to move too much CFM for cooling. Probably still on factory setting. A slower speed will lower SA temp, increase SA RH and increase Delta T RA-SA.

    Is...
  37. Replies
    15
    Views
    550

    Just put a sprinkler on it and adjust flow to the...

    Just put a sprinkler on it and adjust flow to the h ad you are want. Fan type sprinkler set to spray at the top of the coil works well.
  38. Replies
    13
    Views
    502

    1100 Sq Ft house with a full basement does not...

    1100 Sq Ft house with a full basement does not need 2 systems. Depending on when it was built and how well it is insulated it may be hard to find 1 that is small enough.

    2 stg may not give you...
  39. It could be the suction on the trap is greater...

    It could be the suction on the trap is greater than the weight of the water so it sucks the water out of the trap. It could be that when you looked at it it let the trap fill enough that water...
  40. Replies
    1
    Views
    232

    From what I read on it it sounds like there is a...

    From what I read on it it sounds like there is a bad zone sensor, or maybe not bad but not connected to the panel correctly.

    It could also be that they have 2 sensors with the same address. The...
  41. Replies
    29
    Views
    801

    That's always another clue to watch for.

    That's always another clue to watch for.
  42. Thread: heatpump

    by BNME8EZ
    Replies
    13
    Views
    468

    Look at your control wiring. Carrier liked to...

    Look at your control wiring. Carrier liked to put in an amp sensor, amps aren't right it don't run.

    And for the record, running a system for a few seconds you can't know that the charge is right....
  43. Replies
    29
    Views
    801

    Easy, when the contacts are pitted worse than a...

    Easy, when the contacts are pitted worse than a teens face with a bad case of acne then it is past time.
  44. Since you say the unit is old that is probably...

    Since you say the unit is old that is probably not the original cap, someone changed it.

    In the process of the change they damaged a terminal/wire end and over time this got worse and caused...
  45. Replies
    29
    Views
    801

    If you test it and it checks as weak or if you...

    If you test it and it checks as weak or if you can see that it is leaking sure tell the customer what it going on and give them the option to do it now or later when it is not as convenient.

    But...
  46. Is the 28 F or C. It sounds like they have the...

    Is the 28 F or C. It sounds like they have the WSHPs plumbed in series where water goes in one unit then out to the next so each unit gets hotter water entering. Each unit should have a return line...
  47. Replies
    33
    Views
    653

    It sounds like the compressor is running, that...

    It sounds like the compressor is running, that would be the hum. The heat also indicates that the compressor is pumping causing the heat.
  48. Replies
    31
    Views
    947

    I know of no technology where it is best to get...

    I know of no technology where it is best to get in on the first off the line, cars, phones, HVAC, etc it really does not matter.

    There will be bugs in the 1st generation of any product. There...
  49. You may want to have an electrician come in and...

    You may want to have an electrician come in and check for loose/bad connections, bad grounds and neutrals, maybe even the wire coming into the entrance from the pole.

    You may also want your...
  50. Replies
    40
    Views
    1,225

    Yup, kinda like Hotel California, you can check...

    Yup, kinda like Hotel California, you can check out any time you like but you can never leave!