  1. Replies
    29
    Views
    583

    Okay, sometimes people call the condenser a...

    Okay, sometimes people call the condenser a compressor.
  2. Replies
    29
    Views
    583

    Are you calling the condenser a compressor, or...

    Are you calling the condenser a compressor, or actually talking about the compressor.
  3. Replies
    29
    Views
    583

    A 240 volt compressor does NOT require a ground....

    A 240 volt compressor does NOT require a ground. It is as the tech said, a personal safety issue. But it did NOT cause your compressor to burn out.

    Something else caused it to burn out/short to...
  4. Replies
    29
    Views
    583

    Compressor doesn't require a ground for it to...

    Compressor doesn't require a ground for it to operate.

    Lots of compressors out there that are not grounded, or grounded properly.
  5. Replies
    46
    Views
    708

    A weak compressor wouldn't draw a high vacuum on...

    A weak compressor wouldn't draw a high vacuum on either line.

    The slight vacuum on the small line just shows that a small amount of refrigerant is being pumped. Which points to a low charge.
  6. Replies
    46
    Views
    708

    No, still looks like a low charge.

    No, still looks like a low charge.
  7. Replies
    4
    Views
    287

    Moved to the Junk Yard forum. This is the...

    Moved to the Junk Yard forum.

    This is the forum foe selling things.
  8. Prices are not allowed, I removed them.

    Prices are not allowed, I removed them.
  9. Replies
    15
    Views
    366

    Moved to AOP.

    Moved to AOP.
  10. Replies
    5
    Views
    276

    Verify air flow is not low. What is the temp...

    Verify air flow is not low. What is the temp split across the evap coil/air handler.
  11. Replies
    46
    Views
    708

    On a mini split, that small line is not a liquid...

    On a mini split, that small line is not a liquid line.

    You described a system low on charge.
  12. Replies
    6
    Views
    147

    Hope those 8 flex ducts are a combination of 8...

    Hope those 8 flex ducts are a combination of 8 and 9" ducts. Other wise you have a low air flow issue.

    And your 24x30 return grille is a bit small for a 4 ton system.
  13. Replies
    1
    Views
    143

    Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  14. Replies
    17
    Views
    256

    Prices are not allowed, I removed them.

    Prices are not allowed, I removed them.
  15. Replies
    12
    Views
    785

    That thermostat doesn't have a settable extended...

    That thermostat doesn't have a settable extended fan option.
  16. Replies
    12
    Views
    785

    Nope, thats not it. Whats the full model...

    Nope, thats not it.

    Whats the full model number of your thermostat.
  17. Has someone else been working on it recently.

    Has someone else been working on it recently.
  18. Replies
    12
    Views
    785

    In the installer menu, thee are extended fan run...

    In the installer menu, thee are extended fan run time options.
  19. Sorry, prices are not permitted here, they have...

    Sorry, prices are not permitted here, they have been removed.
  20. LOL. Only Pro members have PM privileges. So...

    LOL.

    Only Pro members have PM privileges. So the OP can't send or receive PMs.
  21. Replies
    19
    Views
    417

    Moved to AOP.

    Moved to AOP.
  22. Replies
    14
    Views
    365

    Moved to AOP.

    Moved to AOP.
  23. Good chance, its just the thermostat.

    Good chance, its just the thermostat.
  24. 1500 CFM is probably fine being that its in first...

    1500 CFM is probably fine being that its in first stage.
  25. Replies
    1
    Views
    107

    Maybe get a better company to service your unit....

    Maybe get a better company to service your unit. One that will find and fix the leak.
  26. Replies
    7
    Views
    296

    Too powerful of a furnace won't cause the A/C to...

    Too powerful of a furnace won't cause the A/C to freeze up. You have a low air flow issue most likely. Or an improperly installed evap coil.
  27. Replies
    7
    Views
    274

    Is your employer your wife? Your a DIYer.

    Is your employer your wife? Your a DIYer.
  28. Replies
    10
    Views
    241

    Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  29. Replies
    17
    Views
    459

    The dye travels with the oil, which travels with...

    The dye travels with the oil, which travels with the refrigerant.

    Its a relatively small amount of oil that travels with the refrigerant, so not much oil or dye circulates in 30 minutes.
    ...
  30. Replies
    5
    Views
    199

    Honeywell IAQ.

    Honeywell IAQ.
  31. Replies
    17
    Views
    459

    Some leaks are hard to find. And need to have the...

    Some leaks are hard to find. And need to have the system recovered except for a few ounces as trace gas, and then nitrogen used to bring the system up to a high pressure and checked.

    Most leak...
  32. Replies
    46
    Views
    854

    Yes.

    Yes.
  33. Replies
    19
    Views
    649

    5,000 sq foot house with a 4 ton A/C. 1,250 sq ft...

    5,000 sq foot house with a 4 ton A/C. 1,250 sq ft per ton, on a 20 plus year old house. Might be a tad small.

    Same with furnace.

    Ask the company how they determined what size equipment to...
  34. Replies
    23
    Views
    478

    I only use the contractor models. So I don't know...

    I only use the contractor models. So I don't know which if any box store models have it or not.
  35. Replies
    23
    Views
    478

    Its not a feature that automatically pops up. If...

    Its not a feature that automatically pops up. If your thermostat has that feature. It has to be enabled in the set up menu.
  36. Replies
    45
    Views
    675

    Ah, forgot its an electric furnace. Its okay...

    Ah, forgot its an electric furnace. Its okay then. I was thinking gas furnace at first.


    And on a side note. Have them check if one of the electric heaters is coming on with the A/C.
  37. Replies
    45
    Views
    675

    The A coil is NOT suppose to be on top of a...

    The A coil is NOT suppose to be on top of a downflow furnace. Its detrimental to the furnace. Causes the heat exchanger to rust from the inside out.
  38. Replies
    45
    Views
    675

    A coil on top? Is this an upflow or downflow...

    A coil on top? Is this an upflow or downflow furnace?
  39. Replies
    41
    Views
    923

    From what several members said a long time ago....

    From what several members said a long time ago. It was common in Florida at one time.
  40. Replies
    45
    Views
    675

    More often than not, techs don't crawl under the...

    More often than not, techs don't crawl under the home and check the ducts.
  41. Replies
    4
    Views
    229

    Could be a orifice/TXV issue, or a low air flow...

    Could be a orifice/TXV issue, or a low air flow issue, or a restricted LLFD issue.

    SH and SC would have probably pointed you in the right way.
  42. Replies
    45
    Views
    675

    Should check to make sure non of the ducts under...

    Should check to make sure non of the ducts under the home are disconnected. And make sure the ducts are properly attached to the unit.
  43. The Ultra Aire will be a higher quality unit.

    The Ultra Aire will be a higher quality unit.
  44. No, its not harmful. And might even save enough...

    No, its not harmful. And might even save enough money in ten years to pay for the insulation.
  45. Replies
    23
    Views
    478

    We have a contractor locator map of this boards...

    We have a contractor locator map of this boards members. See if any are listed on it. The link to it is in my sig.
  46. Prices removed.

    Prices removed.
  47. Replies
    41
    Views
    923

    Your not charged based on amp draw. But rather by...

    Your not charged based on amp draw. But rather by wattage. Many forget this when they see a lower amp draw on a 3 phase unit the same size as a single phase unit.

    Same amount of wattage whether...
  48. A good nitrogen flush/purge is all that is needed.

    A good nitrogen flush/purge is all that is needed.
  49. Yes, you posted prices. I also removed the new...

    Yes, you posted prices.

    I also removed the new prices you posted.

    https://hvac-talk.com/vbb/showthread.php?1241-Welcome-to-HVAC-Talk!-Please-read-these-rules
  50. Prices are not allowed.

    Prices are not allowed.