  1. Replies
    5
    Views
    185

    “ my ac unit is carrier Performance 2 ton 24,000...

    “ my ac unit is carrier Performance 2 ton 24,000 BTUs 16 SEER, 13 EER 24acb724a310 and the furnace is Carrier Infinity 98 59MN7A060V17 “

    Curious if the Installing Contractor gave you the AHRI...
  2. Heat Pumps have many more parts and sits outside...

    Heat Pumps have many more parts and sits outside in the elements compared to a basic uncomplicated indoor sitting 80% furnace, ( potential future service calls probably will be higher with the HP )...
  3. Replies
    9
    Views
    259

    Post some photos to get some perspective..

    Post some photos to get some perspective..
  4. Believe I read in the brochure you can order that...

    Believe I read in the brochure you can order that OD unit with built in high and low pressure controls from the factory, at an added cost, if that interest you, as that unit is pretty bare bone or...
  5. https://www.ahridirectory.org/Home/Download?Refere...

    https://www.ahridirectory.org/Home/Download?ReferenceId=sUzbLVC3/aFB9wkj0dGAH/JUctAYQHucs/p6ClJm7joq+tnZkVnP7sOZS1cNINuY

    Doesn’t sound like they did much of a commissioning report on your system,...
  6. https://www.ahridirectory.org/Home/Download?Refere...

    https://www.ahridirectory.org/Home/Download?ReferenceId=sUzbLVC3/aFB9wkj0dGAH+LDu7SYQB5JKPGy9yPMK51MoVaFk7mCm/x5HZHuzm7a

    All matched system, the furnace probably can qualify for any rebates your...
  7. What’s the model numbers of the OD unit and ID...

    What’s the model numbers of the OD unit and ID unit.

    Did they just install the ID and OD unit size the same as your old system?
  8. You seem proactive about your system, so I would...

    You seem proactive about your system, so I would suggest reading the install guide as it should say what the manufacturer wants for a static pressure, then research how it’s done, then call the...
  9. Maybe they left the fan speed at the default...

    Maybe they left the fan speed at the default setting from the factory, the install guide of the OD unit gives very specific subcooling/superheat setting they want the Contractor to follow once air...
  10. Replies
    21
    Views
    892

    You should not compare your old Heil air...

    You should not compare your old Heil air temperature to your original discharge air temperature, who knows how they set up that unit initially, ( Heil ) may have charged to beer can cold vapor line...
  11. Replies
    21
    Views
    892

    Everything is to your satisfaction? Energy star...

    Everything is to your satisfaction? Energy star rated AHRI matched system installed with a certificate showing either 15 or 16 SEER?, ( 16 SEER, better chance at rebates if you have any ) ...
  12. Replies
    2
    Views
    177

    Going with higher SEER systems, they tend to be...

    Going with higher SEER systems, they tend to be complicated, so if going that route you would need to make sure the Bidding Contractors are well versed in that model. Class participation,...
  13. Replies
    47
    Views
    874

    https://www.harley-davidson.com/us/en/motorcycles/...

    https://www.harley-davidson.com/us/en/motorcycles/future-vehicles/livewire.html

    Not just cars, many other brands already in production
  14. I would not assume your neighbors unit ductwork...

    I would not assume your neighbors unit ductwork are automatically the same as yours, certainly it can be...woooww 100 A/C condensing units on the roof? I suppose the hatchway can get busy at times in...
  15. Who’s pays for HVAC repairs? If it’s you I would...

    Who’s pays for HVAC repairs? If it’s you I would say you have more recourse. Make friends with a neighbor(s) that have a similar set up to compare.

    BTW as you know the indoor coil is rated at up...
  16. Replies
    16
    Views
    462

    .

    .
  17. Replies
    28
    Views
    967

    Winter months,...Did you notice if the system...

    Winter months,...Did you notice if the system stays in defrost the same amount of time before termination, no matter the OD temperature? as it should vary, if it does not vary it may trip on the HPC...
  18. Replies
    17
    Views
    350

    Possibly the sheet metal cover is up there...

    Possibly the sheet metal cover is up there somewhere, goes in between the slips, if you donít relocate or have the option for your Air Filter.
  19. Replies
    28
    Views
    967

    Have your Contractor call Goodman Technical Rep....

    Have your Contractor call Goodman Technical Rep. ( as they usually do not deal with homeowners ) have them give the model number and have them ask what size and pitch and how many blades and RPM of...
  20. Replies
    3
    Views
    236

    Possibly they added a short piece of copper to...

    Possibly they added a short piece of copper to the existing lineset, as the insulation on the larger line at the very least looks new.

    Is that the final resting place of the OD unit, and the...
  21. Replies
    5
    Views
    317

    You don’t mention if you have to add refrigerant...

    You don’t mention if you have to add refrigerant to your system. If you had to add refrigerant that shiny discharge from the condensate drain terminating outside could be the system oil.

    I would...
  22. Replies
    21
    Views
    892

    One source for rebates ...

    One source for rebates

    https://www.dsireusa.org/

    Seeing that they are going to give you a AHRI rated system that proves a match hopefully by giving you a AHRI number or better yet the...
  23. Replies
    21
    Views
    892

    What does that mean? What are they going to...

    What does that mean? What are they going to install/replace..did they at least tell you in advance or is that going to be a big surprise? A new 16 SEER rated OD unit hooked to your ARUF, if so you...
  24. Replies
    10
    Views
    446

    Why don’t you do a load calculation 1st, that...

    Why don’t you do a load calculation 1st, that alone may tell you that you may get by with a smaller unit.

    Here’s a free one: http://www.loadcalc.net/

    I suppose to a degree the voltage to your...
  25. Replies
    9
    Views
    221

    If your leaning towards Heat Pumps and another...

    If your leaning towards Heat Pumps and another source of switch over, they make two types of Air to Air Heat Pumps. Demand defrost and time/temperature. Chances are the demand defrost will initiate a...
  26. “I am thinking of replacing these units with a...

    “I am thinking of replacing these units with a current model with good warranty for parts and labor.”

    The standard 10/10 compressor and parts warranty, even when you register it, reverts to a 5/5...
  27. Pitfall...yes don’t automatically assume what the...

    Pitfall...yes don’t automatically assume what the Contractors are pitching such as a 16 SEER rated OD unit, that your paying for and getting that rating. It’s a combination of matching the ID section...
  28. Replies
    20
    Views
    833

    Frosty 25.....Starting at the Communicating 16...

    Frosty 25.....Starting at the Communicating 16 SEER A/C GSXC16 and Heat Pump GSZC16 they also come with a 10 year whole new OD unit replacement warranty if compressor ever fails, once registered then...
  29. Replies
    11
    Views
    347

    http://www.building-center.org/comfortmaker-hvac-a...

    http://www.building-center.org/comfortmaker-hvac-age/

    That format looks to be style 3 and under the Snyder General umbrella. Still hard to determine when yours was exactly built. Looks like they...
  30. Replies
    46
    Views
    2,000

    The carrot on the stick is the owner will offer...

    The carrot on the stick is the owner will offer to sell the business to him once retirement comes around, as owner(s) are 55ish....only OP knows....

    There’s a saying, while your climbing the...
  31. Replies
    20
    Views
    833

    Where you been?......Goodman was the 1st company...

    Where you been?......Goodman was the 1st company to offer the 10/10 compressor and parts warranty in 2008 I believe, and if you installed Goodman units in 2007 and registered with the 5 year...
  32. Replies
    21
    Views
    892

    https://www.acwholesalers.com/manuals/b525a123fc3e...

    https://www.acwholesalers.com/manuals/b525a123fc3e79657b02f5822f14e0c6.pdf dated 2016 shows

    Page 61 shows three Air Handlers that give the 15 SEER on paper with AHRI numbers proving that. None...
  33. Replies
    11
    Views
    347

    Remember Arcoaire and the Comfortmaker line being...

    Remember Arcoaire and the Comfortmaker line being under the Snyder General badge in that time frame. If your interested, post the serial number and we should be able to tell the age of that unit.
  34. Somewhere in your post you mentioned finding the...

    Somewhere in your post you mentioned finding the Goodman piston attached to the OD unit, while system was open, did you give to tech to see what the First Co. piston was rated at, as the sizes are...
  35. If that is what you seen, that He then topped off...

    If that is what you seen, that He then topped off what was released into the atmosphere. Certainly that is not legal.

    “Coils are clean, this is a brand new unit, installed not too long before I...
  36. “After reconnecting everything he did not pull a...

    “After reconnecting everything he did not pull a vacuum. I was not watching when he opened the condenser unit back up to the lines but I did hear quite a bit of "purging" sound. Assuming he knew a...
  37. Yes, sorry I took that Carrier number as the...

    Yes, sorry I took that Carrier number as the outdoor unit, need the model number and brand of the outdoor unit, and of course the furnace model number and brand as mentioned...
  38. Was curious as to even the furnace was rated to...

    Was curious as to even the furnace was rated to handle upwards of 4 tons.

    Certainly you can query them about that mismatch, see what they say and do.
  39. What’s the model number and brand of the OD unit...

    What’s the model number and brand of the OD unit and the model number and brand of the indoor coil. What’s the model number and brand of the furnace, as it seems you have a cased or uncased coil and...
  40. Replies
    46
    Views
    2,000

    Knowing when your on call is certainly a plus,...

    Knowing when your on call is certainly a plus, not guessing it’s a plus, as you can schedule important events around those dates.

    Decision, Decisions ,...as you mentioned today is the day...it’s...
  41. Replies
    1
    Views
    158

    Speaking of Chernobyl fiasco, ...

    Speaking of Chernobyl fiasco,

    https://www.cbsnews.com/news/atomik-vodka-chernobyl-disaster-liquor-company-radiation/

    Only one bottle produced so far...according to this article...
  42. If your a stickler for AHRI matched systems, have...

    If your a stickler for AHRI matched systems, have Bidding Contractors bid lower SEER matched Indoor to Outdoor unit, as with your older existing furnace you’ll be hard pressed to get anything more...
  43. Replies
    4
    Views
    352

    https://www.anthonyphc.com/blog/ecm-fan-motor-mand...

    https://www.anthonyphc.com/blog/ecm-fan-motor-mandate/

    Could be wrong, but I’m only aware that manufacturers will be installing only ECM motors in furnaces as of 3 July 2019. PSC motors will be...
  44. Replies
    46
    Views
    2,000

    IMO your thinking like a 39 year old, sorry 39...

    IMO your thinking like a 39 year old, sorry 39 year young man, if you could fast forward to 50-60 years old, with no benefit package I’m guessing you may look back at your life and think...
  45. Replies
    46
    Views
    2,000

    Easy decision for me, go in house with the...

    Easy decision for me, go in house with the benefit package, guessing less stress, get home at more normal times, you don’t mention what weather your dealing with, winter snow, hot summer roofs and...
  46. Believe you contact the Installing Contractor for...

    Believe you contact the Installing Contractor for the up to 10 year extended labor warranty, believe the Contractor would have to be willing to participate in those plans, as the labor rate ( Lennox...
  47. If your overly concerned with either coil, ( both...

    If your overly concerned with either coil, ( both should have a 10 year warranty once registered. ) Purchase a extended labor warranty from Lennox for your Aunt, so no one takes a persevered...
  48. Replies
    26
    Views
    741

    May confuse a Tech. a bit,...:whistle:

    May confuse a Tech. a bit,...:whistle:
  49. “ If I do have to replace it myself would it be...

    “ If I do have to replace it myself would it be better to go with an ac and furnace or should I stick with a heat pump? “

    Model number you provided says you have a straight A/C not a Heat Pump,...
  50. Replies
    4
    Views
    180

    Should be checked to subcooling or superheat or...

    Should be checked to subcooling or superheat or both, not by just throwing on a set of gauges and checking pressures. Whatever the install guide says for the OD unit. If your a proactive person, I’m...
Results 1 to 50 of 1000