Search:

Type: Posts; User: TPARSONS64

Search: Search took 0.01 seconds.

  1. Now that I am thinking about it, a bad board will...

    Now that I am thinking about it, a bad board will be an extended freeze time....a bad bin switch would go off on an extended harvest time code.

    Tim Parsons
  2. I don't think you need to download it. I think he...

    I don't think you need to download it. I think he is correct. It should be in the history of the controller.

    Tim Parsons
  3. Well....a weak bin switch won't cause it to not...

    Well....a weak bin switch won't cause it to not harvest but can make double slabs. But sure....why not...it's cheaper for sure

    Tim Parsons
  4. Call tech support and ask for Barry Hett or Tom...

    Call tech support and ask for Barry Hett or Tom Lee.....thats who I talked to when I worked on and represented Manitowoc....I don't know if they are still there....

    Tim Parsons
  5. Bad board...or thats what I was taught by the...

    Bad board...or thats what I was taught by the best at Manitowoc....but that was on the older machines. Don't have a ton of training or experience on Indigo models

    Tim Parsons
  6. Replies
    46
    Views
    4,277

    You will be leaving a job that is in the private...

    You will be leaving a job that is in the private sector and for discussions sake.....going to a Government job.....although that is not a precise statement. If you are looking for job...
  7. Replies
    86
    Views
    38,714

    Hell yeah....I know Voyagers very well and the...

    Hell yeah....I know Voyagers very well and the jumper procedure sucks. I will buy one for sure. Great idea dude!!!....Also......to test the unit to run in auto mode....can you put a setting on it to...
  8. Replies
    21
    Views
    2,159

    To be precise....and that's an inside joke right...

    To be precise....and that's an inside joke right now....that is called Liquid Line Solenoid drop....mostly to stop refrigerant migration in the off cycle. IN my opinion...every single piece of...
  9. Replies
    65
    Views
    4,443

    When I was learning when I first got into this...

    When I was learning when I first got into this trade......yes. Let me explain. What gauges are better to be precise.......or to repair and diagnose a system? Traditional gauges or digital gauges?...
  10. Replies
    33
    Views
    3,778

    I never heard that........thank you! Tim...

    I never heard that........thank you!

    Tim Parsons
  11. Replies
    65
    Views
    4,443

    Probably not enough.....being precise is not my...

    Probably not enough.....being precise is not my objective. It is to provide my experience and opinion to help people diagnose troublesome service problems that only can be found be trial and error....
  12. Replies
    65
    Views
    4,443

    It is not a balanced ported by the number you...

    It is not a balanced ported by the number you shared on the valve. That is a standard Sporlan TXV. I thing that is a sweat R22 valve but the last number eludes me....it should be a C for medium temp...
  13. Replies
    47
    Views
    2,874

    Your head pressure should be the same no matter...

    Your head pressure should be the same no matter where you are taking it on the high side of the system. Your superheat should be 20 degrees at the compressor on a cooler. Regradless, I would recover...
  14. Replies
    11
    Views
    898

    All larger freezer boxes have drain lines on the...

    All larger freezer boxes have drain lines on the evap. A heat tape installed correctly which i wrapping the cable around the pipe and using 3/4" insulation is the proper way to install a drain line....
  15. Replies
    34
    Views
    2,012

    If you disconnect the ice thickness probe, you...

    If you disconnect the ice thickness probe, you have a bad board.
  16. Replies
    34
    Views
    2,012

    Bad board

    Bad board
  17. Replies
    13
    Views
    1,047

    By what you are describing, you have a pump down...

    By what you are describing, you have a pump down system. N is common for the circuit to complete power through the normal open contacts which should be terminal 3 which are the defrost heaters, and...
  18. Replies
    2
    Views
    490

    Get the whole pump, the kit is just a seal kit

    Get the whole pump, the kit is just a seal kit
  19. Replies
    21
    Views
    2,159

    Pumpdown is preferred but for an off cycle...

    Pumpdown is preferred but for an off cycle defrost is not manditory....if everything else is working ok. In extreme cold ambient temperatures, you may have a liquid migration problem, then pumpdown...
  20. Replies
    15
    Views
    4,429

    BTW.......by you posting the equipment info...

    BTW.......by you posting the equipment info triggered my comment on the model and serial info. Good man!
  21. Replies
    15
    Views
    4,429

    I am going to sound like an ******* here....not...

    I am going to sound like an ******* here....not my intentions. This is a general response.....A model number would be appropriated..and ambient temps along with water temps. Also, an icemaker has to...
  22. Replies
    33
    Views
    3,778

    That stuff never worked.......probably a dirty...

    That stuff never worked.......probably a dirty evaporator, or plugged water distributor tunes or poor water flow. I would clean the evaporator wand check the other items mentioned. I would also grab...
  23. Replies
    19
    Views
    1,313

    For sure it is either a water fill issue or you...

    For sure it is either a water fill issue or you are leaking water by down the check valve during a freeze. Check water pressure and fill times and full sump and I always lower the float switch a tad...
  24. Replies
    14
    Views
    1,023

    If you are referring to defrost or harvest as...

    If you are referring to defrost or harvest as purge...then I would leave it alone. Hoshi's have a tendency to freeze up if the harvest timers are not maxxed out....especially on remotes. If the purge...
  25. I would not recommend that....plating evaporators...

    I would not recommend that....plating evaporators is a very technical process. I would change the evaporator for many reasons. Or replace the machine

    Tim Parsons
  26. Replies
    57
    Views
    3,080

    Brush them off weekly and install a pre-cooler on...

    Brush them off weekly and install a pre-cooler on the condenser coil....actually the pre-cooler should wash the coils now that I am thinking about it

    Tim Parsons
Results 1 to 26 of 26