  1. Replies
    44
    Views
    551

    Well,...hopefully the TXV and subcooling...

    Well,...hopefully the TXV and subcooling adjustment and whatever else he does solves your problem. Can’t do a whole lot until repairs are made... when do you expect him back?
  2. Replies
    23
    Views
    429

    You should take care of the auxiliary drain pan,...

    You should take care of the auxiliary drain pan, have them install a sensor of some sort in there to shut system off, before damage is done.

    Call out the crack HVAC company who installed it,...
  3. Replies
    44
    Views
    551

    15 degree difference, you at least got a number...

    15 degree difference, you at least got a number to compare when he does his thing whenever he comes back out. Ask yourself what was the OD and ID temperature when he got that number, did he let the...
  4. Here’s one free one ...

    Here’s one free one
    ...
  5. Replies
    44
    Views
    551

    Maybe it was a relatively cooler days? Who knows..

    Maybe it was a relatively cooler days? Who knows..
  6. Replies
    44
    Views
    551

    If the Tech. Is going to install a TXV kit...

    If the Tech. Is going to install a TXV kit hopefully it’s rated for your system, at 4 ton. Also you don’t replace the piston, you remove the existing one when installing the TXV. Make sure he gives...
  7. Replies
    12
    Views
    235

    May want to have the Tech. call Technical Service...

    May want to have the Tech. call Technical Service or some other department of Maytag/Nortek if they can’t find it on your internet search. Have them show the photo and model and serial number. A...
  8. Replies
    12
    Views
    158

    .

    .
  9. Replies
    9
    Views
    213

    If your as good as you say you are and have...

    If your as good as you say you are and have attention to detail, very few call backs, ( don’t smash up the service trucks regularly :whistle: ) excellent attendance, strong work ethic, all that good...
  10. You can try to buy some self adhesive felt...

    You can try to buy some self adhesive felt insulation ( after cleaning general area ) depending on age of that unit it could easily ( insulation ) deteriorated over the years.

    The ones I’ve seen...
  11. Would have been nice if the retired Tech. gave...

    Would have been nice if the retired Tech. gave you a recommendation of a reputable knowledgeable HVAC person, as tradespeople network typically.
  12. So your saying ( with system at off position at...

    So your saying ( with system at off position at the t-stat ) if you just put the blower fan to ON position, the blower fan comes on, nothing else yes? If so then if you leave the fan switch at the...
  13. If you put the fan to ON position and the A/C on...

    If you put the fan to ON position and the A/C on does the A/C stay on or even come on and it cools the residence? If so should not be a difficult fix. At 50 years old, the wiring and operation got to...
  14. Replies
    9
    Views
    213

    $7.00 dollar increase in 3 years...not to shabby....

    $7.00 dollar increase in 3 years...not to shabby. Maybe this person has more licenses or higher tier license than you. Maybe the benefit package that this person has is not as generous as yours....
  15. Replies
    27
    Views
    410

    They should be checking your charge according to...

    They should be checking your charge according to this manufacturers chart, page 12. The airflow to page 10, next time they come out. Dated 2011, close to when your unit was built and properly current...
  16. Replies
    27
    Views
    410

    Guessing they probably buried the cost into the...

    Guessing they probably buried the cost into the labor as itís such a low dollar item if they said it was under warranty?
  17. Replies
    27
    Views
    410

    Check to make sure you can see completely through...

    Check to make sure you can see completely through the coil, and not just the outside surface area looks clean.
  18. Replies
    27
    Views
    410

    If you registered your unit, you get a 10/10...

    If you registered your unit, you get a 10/10 compressor and parts warranty and that capacitor should not cost you anything.
  19. Replies
    27
    Views
    410

    Why should refrigerant be added if there is no...

    Why should refrigerant be added if there is no leak, considering it worked great the 1st four years?

    If ductwork is truly sealed properly, blower speed set correctly, return sized correctly.
    ...
  20. Replies
    27
    Views
    410

    So you had 4 Techs. out and that’s all they did,...

    So you had 4 Techs. out and that’s all they did, nothing about changing blower speeds, adding/removing refrigerant etc.

    How about regular PM checks did you ever have any done the 4th year? as you...
  21. Replies
    27
    Views
    410

    This ones dated 2011 says you have a PSC blower...

    This ones dated 2011 says you have a PSC blower motor, the 5 ton has the EEM motor. Says it’s a three speed.
    ...
  22. Replies
    27
    Views
    410

    What model number is the unit. If you have a...

    What model number is the unit. If you have a basic PSC motor and even the ECM motor they are multi tapped blower speed.

    What did all the invoices they gave you said in regards to what they did?
  23. Replies
    27
    Views
    410

    Guessing they changed the blower speed to get...

    Guessing they changed the blower speed to get that 21-25 degree differential? If they changed the blower speed to get those numbers what was it before the change, as guessing it was set at a higher...
  24. The thing sticking up on your copper line with...

    The thing sticking up on your copper line with the two wires ( last photo ) is your low pressure safety control.....if you also have one on the smaller diameter copper line, that’s your high pressure...
  25. Replies
    23
    Views
    429

    Are you a daring person? Easy enough to find out,...

    Are you a daring person? Easy enough to find out, stick a thin dull tipped rod 2”-3” in away from the coil, on upper part away from the lineset connections, if it goes in that far it’s Fiberboard, if...
  26. Replies
    3
    Views
    142

    Do a load calculation to see what you need, there...

    Do a load calculation to see what you need, there are free ones online. What did the Contractor say about your existing ductwork, can it handle a slightly larger tonnage system? Does your existing...
  27. Replies
    23
    Views
    429

    Hopefully you can get satisfaction from the...

    Hopefully you can get satisfaction from the installing Contractor in getting your system running properly. Hopefully your system got registered as manufacturers warranty decreases significantly if...
  28. Replies
    23
    Views
    429

    Looks like the plenum is made from fiberboard...

    Looks like the plenum is made from fiberboard from here, covered in a bunch of foil tape, and mastic sealing. Or it could be fiberboard covering the sheetmetal Plenum to keep the metal from...
  29. Replies
    23
    Views
    429

    ďAnother time the drain pan overflowed and water...

    ďAnother time the drain pan overflowed and water leaked through the attic decking and living area drywall. The condensation line was clogged, it turns out, though the installer said he'd cloroxed it...
  30. Hopefully once you get your system dialed in from...

    Hopefully once you get your system dialed in from the Contractor, and have them give you some scenarios. Hopefully they registered your system, as Daikin gives an outstanding manufacturer warranty (...
  31. Didn’t the installing Contractor explain all the...

    Didn’t the installing Contractor explain all the different sequences of operation scenarios before leaving? If not give them a call. What is the switchover temperature, 40 degrees?

    Did they check...
  32. Replies
    2
    Views
    136

    Pretty much all manufacturers offer a aluminum...

    Pretty much all manufacturers offer a aluminum indoor coil. Thinking if bidding Contractors bids a ADP or Aspen indoor coil, your likelihood of getting a copper coil may increase.

    Rust on a indoor...
  33. Replies
    11
    Views
    207

    [QUOTE=markg1;25871141]i asked for the matched...

    [QUOTE=markg1;25871141]i asked for the matched set, guess i am in for a fight since the AHRI allows for the match. thanks for the help, at least i know it will work, just cost me more long...
  34. Replies
    11
    Views
    207

    You can use that also as it’s a active AHRI match...

    You can use that also as it’s a active AHRI match # 203372590 gives 14.5 SEER and a slightly higher EER at 12.5.

    It’s your money, you can request any combination.
  35. Replies
    11
    Views
    207

    AHRI number 203372591 shows it’s a match. Says...

    AHRI number 203372591 shows it’s a match. Says 14.5 SEER and 12 EER.
    ...
  36. Replies
    44
    Views
    551

    Or you can use Aspen TXV number 4204 ( X6-5 kit )...

    Or you can use Aspen TXV number 4204 ( X6-5 kit ) which is a 20% bleed. The 4202 is not a non bleed if you go TXV.

    If you go TXV, follow the install guide of the Goodman outdoor unit, they...
  37. Replies
    44
    Views
    551

    That coil is not a AHRI match as it does not list...

    That coil is not a AHRI match as it does not list the CM48E3F, it lists the CM48E34 as a match. Which has the TXV. 4=TXV

    All you got to do is install a OEM field install R410A TXV on your existing...
  38. Replies
    44
    Views
    551

    http://aspenmfg.com/Content_Matrix/Spec_Sheets/CM-...

    http://aspenmfg.com/Content_Matrix/Spec_Sheets/CM-SS-102519.pdf

    Unless I’m reading something differently, says that factory piston metering device the “F” in the Aspen model number Is for R22 and...
  39. Replies
    23
    Views
    457

    Never heard of that myself. Once equipment is...

    Never heard of that myself. Once equipment is registered Rheem gives the original registered owner a standard 10/10 compressor and parts warranty. If equipment is never registered then you get a base...
  40. Replies
    44
    Views
    551

    Seeing you have a different coil brand to blower...

    Seeing you have a different coil brand to blower system ( page 8 figure 10 ) maybe the coil is not a correct fit, and your bypassing a little room air ( return air ) around the coil, instead of all...
  41. Replies
    44
    Views
    551

    Model numbers not serial numbers...

    Model numbers not serial numbers...
  42. Replies
    44
    Views
    551

    OK so you have a existing blower assembly and...

    OK so you have a existing blower assembly and just changed the indoor coil and OD unit?

    Your 1st post says you got a “Recently I got my “whole “ hvac system replaced in my double wide “

    Then...
  43. Replies
    44
    Views
    551

    Unfortunately the piston metering device is...

    Unfortunately the piston metering device is internal just downstream of the nut by the 3/8” liquid line by the indoor section. Goodman also makes a field installed OEM TXV if your coil came with the...
  44. Replies
    23
    Views
    457

    “I have a credit card that doubles the warranty“...

    “I have a credit card that doubles the warranty“

    What does that mean your labor warranty is doubled? From one to two years?

    Few more quotes before end of day? Ask them if they are bidding...
  45. Replies
    44
    Views
    551

    Guide ( Dated 2015 ) says to use the piston that...

    Guide ( Dated 2015 ) says to use the piston that came with the OD unit, and they give the size for matching equipment. So what size is in there if you have a piston? They should magic marker the size...
  46. Replies
    23
    Views
    457

    Says it’s a match, gives you 16 SEER and 13 EER,...

    Says it’s a match, gives you 16 SEER and 13 EER, should be good enough for any rebates your state or local utility company may offer and for possibly the Federal Tax Credit.

    AHRI number 201294099...
  47. You got the tools and know what to look for and...

    You got the tools and know what to look for and how to use them to check pressures afterwards.

    May want to hire a pro for that part.

    Even if you did qualify for a HX warranty, doubt Goodman...
  48. Replies
    44
    Views
    551

    TXV or Piston metering device, if piston that...

    TXV or Piston metering device, if piston that part needs to be matched to the OD unit, not the ID unit on your matched system.

    What size piston is in there if piston?
  49. That rebate is misleading to a degree as itís a...

    That rebate is misleading to a degree as itís a combo Tax Credit and money in your pocket rebate. Has a double asterisk ** Says Trane participating dealers, that may mean that the dealer needs to be...
  50. Replies
    23
    Views
    457

    Replace, with a matched system. Research single...

    Replace, with a matched system. Research single stage or two stage, research higher SEER units vs lower SEER units, typically higher SEER units get more complicated. Anything will be better than your...