  1. heating loop. roll on

    heating loop. roll on
  2. Replies
    5
    Views
    1,924

    Horizontals--Wouldnt do it.

    Horizontals--Wouldnt do it.
  3. Replies
    11
    Views
    392

    Did you check the discharge temp of the two not...

    Did you check the discharge temp of the two not working?
  4. Replies
    24
    Views
    721

    Everything you just described is normal operation...

    Everything you just described is normal operation of a part start winding. The compressor isnt going to start with half the wingdings energized. I don't ever remember seeing a 06e pump before the...
  5. being it has a comfort link. you could just swap...

    being it has a comfort link. you could just swap that out and put a UPC ( if it doesn't currently have total unit control) and you would then have bacnet.
  6. Replies
    8
    Views
    347

    https://www.carrier.com/commercial/en/us/products/...

    https://www.carrier.com/commercial/en/us/products/chillers-components/water-cooled-chillers/19xr/#documents
  7. Replies
    8
    Views
    347

    812769812770

    812769812770
  8. Replies
    46
    Views
    1,226

    very possible. did you check the other items at...

    very possible. did you check the other items at all. I'm just curious
  9. good points. cable and a family cell bill is...

    good points. cable and a family cell bill is 5-600 a mo.
  10. Replies
    8
    Views
    347

    can you access the upc? I see you have the usb-l...

    can you access the upc? I see you have the usb-l connected.

    do both your tx and rx lights flash on the service tool? and its not on LEN. Im guessing you know that though.
  11. doesnt matter if they are working 2 or 3 jobs....

    doesnt matter if they are working 2 or 3 jobs. unemployment goes by people out of work, not jobs taken.

    And thankfully there are enough jobs for people to work 2 or 3 and not just one. Then with...
  12. Replies
    6
    Views
    444

    it comes with the doas. there are some settings...

    it comes with the doas. there are some settings in there to allow it to be discovered. Took me a while to get the guide. carrier really has shit on these units.
  13. this unit serves a high body count 30x60 room....

    this unit serves a high body count 30x60 room. The demand for fresh air to maintain 775 ppm co2 is about 35% damper. Most of the year the humidity is about 65% So they asked to make the unit...
  14. the head master control should have a heat mode...

    the head master control should have a heat mode bypass relay.
    And set that stat up correctly
  15. Replies
    46
    Views
    1,226

    another thing with ALL rtu units. the factory...

    another thing with ALL rtu units. the factory sized pulley is set for a free flowing concentric ( no static) once you put it on a system with duct work the cfm drops due to static. On every 48...
  16. I have a building that has a Carrier 48LC VFD...

    I have a building that has a Carrier 48LC VFD drive and 3 stages of cooling that work on a single evap.
    I run the first stage of cooling and modulate the vfd to get a 40 deg suction line temp. ...
  17. Replies
    46
    Views
    1,226

    You should also take a look at the txv bulbs. ...

    You should also take a look at the txv bulbs. Back in the day sporlan had it in the documents, now they don't. But the cap tube coming off the sensing bulb must be at the highest point. If it isnt...
  18. Replies
    7
    Views
    319

    the best thing we did was rip out the trane...

    the best thing we did was rip out the trane controllers and replace them with our own.

    lots of good comments as to why the econos may not be keeping up
  19. Replies
    6
    Views
    444

    when I finally got the set up guide I can now...

    when I finally got the set up guide I can now discover the bacnet points.
  20. Replies
    6
    Views
    362

    you want to ask maxburns

    you want to ask maxburns
  21. Replies
    6
    Views
    444

    addison makes the DOAS unit. I havent run across...

    addison makes the DOAS unit. I havent run across the iaire yet.
    Addison uses ALC oem controls. Being they are designated 16 in their address they are supposed to be uploadable to the I-VU. But...
  22. Replies
    6
    Views
    444

    Carrier Doas

    Anyone had any luck communicating with the unit? BACnet of course.
  23. Replies
    3
    Views
    549

    typical carrier there is a molex plug you just...

    typical carrier there is a molex plug you just plug into. after the jumper side is unplugged. If thats an energy x it should still be the same.

    go here...
  24. what is the must need for the constant volume...

    what is the must need for the constant volume through the ah?
  25. Replies
    5
    Views
    429

    no thats the newest

    no thats the newest
  26. can you see these tables? 812098 812099

    can you see these tables?

    812098


    812099
  27. you need to delete all schedule groups in the...

    you need to delete all schedule groups in the I-VU. the system will prioritize that schedule first. Will this fix your issue, not sure. I don't try to bacnet into my own stuff to have that...
  28. Replies
    3
    Views
    362

    where in va are you?

    where in va are you?
  29. email me and I'll give you someones number

    email me and I'll give you someones number
  30. Replies
    4
    Views
    337

    the 5 trane rtu I have at a site have the analog...

    the 5 trane rtu I have at a site have the analog input, and you can set the points with tu or bacnet OR what im doing is using the RH dry contact input to initiate. I use a RIB to isolate the...
  31. Replies
    25
    Views
    1,955

    Dehumidification will suffer. and there are very...

    Dehumidification will suffer. and there are very smart engineers who designed it to work in counter flow. Tell your customer that for proof.


    I'd say a 30% loss in performance minimum.
  32. im rereading your first post as i am logged in...

    im rereading your first post as i am logged in live to a site.
    reference name space temp is the final output for the space temp, nothing is after it in the program.
    SPT is a typical wall sensor...
  33. its possible that the point got locked during...

    its possible that the point got locked during unit start up so the cooling would run. Does the job have an I-vu or equipment touch? you can fix it with that. priority level 16 is the only...
  34. Replies
    13
    Views
    721

    Fixes that

    Fixes that
  35. Replies
    34
    Views
    1,968

    [QUOTE=TechmanTerry;25782083] they never...

    they never calculate make up air. 500k boiler. " but there is space under the door"
  36. Replies
    34
    Views
    1,968

    It varies a lot with what boiler you are...

    It varies a lot with what boiler you are installing. We could be here all night talking about the multitude of options.

    When in doubt read the install manual. It will answer most every question...
  37. Replies
    8
    Views
    770

    have you looked into the things people mentioned?...

    have you looked into the things people mentioned?

    this is 134a right? by your temp drop you have way to much flow or low refrigerant. By the condenser temp rise its low. You're at 100% load...
  38. The pic is from snap. its the program that would...

    The pic is from snap. its the program that would be on the UPC if thats what you are using. you will need field assistant to change those settings. Obviously comfort link isn't doing it. But...
  39. you can move the wires IF it doesn't have staged...

    you can move the wires IF it doesn't have staged air volume or a 2-10 vfd output. Depends on the unit. And the RTU board defaults to a t55 sensor. Even if factory installed I put a duct probe in...
  40. Replies
    13
    Views
    721

    I wouldn't use it if it was new and updated. But...

    I wouldn't use it if it was new and updated. But why would you with I-VU pro. there isn't any new docs on partners about it since 2014.
    I think Balibe may work Carrier which he may have better info.
  41. check the default value. Also set your output...

    check the default value.
    Also set your output to refresh by time not cov.


    811505
  42. you are using the UPC control for bacnet?

    you are using the UPC control for bacnet?
  43. Replies
    16
    Views
    531

    you can do UPC's that's by mstp. or you can...

    you can do UPC's that's by mstp. or you can use a ccn router which would be an IP connection. I dont know how your system works if that would communicate.

    for the router you need service tool...
  44. his description sounds like a fan coil to me.

    his description sounds like a fan coil to me.
  45. so I understand you correctly. there is a...

    so I understand you correctly. there is a chiller supply and return. boiler supply and return. and they both feed a single coil. Sounds like they are using the 3 way as a flow control to match...
  46. Chillerr123 email me. its in my profile.

    Chillerr123 email me. its in my profile.
  47. IVU tools. which is field assistant, equipment...

    IVU tools. which is field assistant, equipment builder snap viewbuilder and apploader you will need the USB -L kit for connecting.
  48. when I say set up im referring to things like...

    when I say set up im referring to things like mode of control, as in always on, remote, or ccn. or dual chiller set up. resets. I just looked at some sites. they are changeable by the UPC...
  49. are these locked? 811235

    are these locked?


    811235
  50. Are you trying here? 811234

    Are you trying here?
    811234