Search:

Type: Posts; User: Bazooka Joey

Page 1 of 20 1 2 3 4

Search: Search took 0.10 seconds.

  1. Replies
    2
    Views
    62

    Should show all the do’s and don’t in the install...

    Should show all the do’s and don’t in the install guide. So if you want to educate yourself, look up the models you plan on considering and read it.

    Make sure they do a start up/commissioning...
  2. Not the best situation, especially with a Heat...

    Not the best situation, especially with a Heat Pump going smaller ID coil to larger OD unit. But it does show a AHRI match.

    Here’s the AHRI with your existing AH and a 4 ton OD unit.
    ...
  3. Replies
    27
    Views
    733

    Thank you for the kind comments..

    Thank you for the kind comments..
  4. Manufacturers offer extended labor warranties...

    Manufacturers offer extended labor warranties also, typically they are either 5 or 10 years. So as an example if the Installing Contractor goes out of business, ( as the labor warranty is backed by...
  5. Replies
    27
    Views
    733

    From another recent post by OP 24ACC630A300...

    From another recent post by OP

    24ACC630A300 and the new Spacepak ESP2430JH4M air handler. One of their certification engineers also helped and could find no match.
  6. Replies
    11
    Views
    380

    What you getting from in-laws a packaged one...

    What you getting from in-laws a packaged one piece unit. To get a idea of amperage draw look at the blower amperage, outdoor fan amperage and compressor amperage of both systems. If your electrical...
  7. Replies
    27
    Views
    733

    If you don’t mind me asking, What’s your next...

    If you don’t mind me asking, What’s your next move? Live with it? Ask for change? Partial Reimburse? More clarification from them for why this set up was chosen?

    What you know now, you probably...
  8. Here’s what matching up excellent means,..at...

    Here’s what matching up excellent means,..at least to me..AHRI certificate er minus the furnace, just an example..
    ...
  9. York covers the refrigerant? What does that mean?...

    York covers the refrigerant? What does that mean? It’s free? Or they are just sliding the refrigerant cost into the bid?

    What does “ so to patch it up went down “ mean?
  10. More pictures would help. As stated if the...

    More pictures would help. As stated if the compressor terminals blew out, there should be oil residue everywhere. So where is the oil residue. If just the connection to the compressor blew out and it...
  11. Their profit margin decreased on this job, as...

    Their profit margin decreased on this job, as none of this is chargeable to you. They probably hate this web-site...:whistle:
  12. Replies
    11
    Views
    509

    What did your Contractor say? if they are worth...

    What did your Contractor say? if they are worth their salt they should know how to get your unit running. Odd the dealer didn’t tell you your options?
  13. OK makes sense if this bid is going in the attic,...

    OK makes sense if this bid is going in the attic, making it horizontal system, using the LH coil.
  14. I give up what gives? In some of your original...

    I give up what gives? In some of your original post your talking a ADP LC coil which is upflow/downflow

    This one says LH, that’s a Horizontal coil, if you have a vertical coil now why the...
  15. Option 3: Upgrade to 19 SEER variable capacity...

    Option 3:
    Upgrade to 19 SEER variable capacity A/C system (Condenser Model# XC20-060) and 2 stage heating system with
    variable speed blower motor (Furnace Model# SL280UH090XV60C) and iComfort WiFi...
  16. Replies
    10
    Views
    305

    Current furnace. 90% @ 95000 BTU input, gives...

    Current furnace.

    90% @ 95000 BTU input, gives you 85500 BTU output.

    Bids.

    96% @ 110000 BTU input, gives you 105600 BTU output.

    96% @ 100000 BTU input, gives you 96000 BTU output.
  17. Replies
    10
    Views
    305

    The Trane XR95 looks to have a 4 speed PSC motor...

    The Trane XR95 looks to have a 4 speed PSC motor whereas the others listed have the variable or constant torque ECM motor.

    Believe as of 3 July 2019 manufacturers stopped production of furnaces...
  18. Replies
    10
    Views
    389

    leaks in the line set and after a few minutes...

    leaks in the line set and after a few minutes they saw some potential issues with the welding work that could be the source of the leak.

    Look at the area(s) they mentioned, if there is oil...
  19. Replies
    7
    Views
    450

    What was the Goodman coil model number, a factory...

    What was the Goodman coil model number, a factory installed TEV comes on models such as the ASPT, CAPT, or flowraters piston comes on model such as the ARUF, or CAUF if it’s a factory installed OEM...
  20. Replies
    12
    Views
    361

    What is the age and size and model number of the...

    What is the age and size and model number of the ID coil section, is the indoor section running on R22 now? Need to be careful when sizing a 14 SEER OD unit to even a 10-12 SEER indoor unit,...
  21. “ I'm still trying to figure out how their GPC14H...

    “ I'm still trying to figure out how their GPC14H systems differ from their GPC15H systems in any meaningful way besides SEER. Or whether there's any particular reason to prefer a GPCxxH system over...
  22. Replies
    7
    Views
    450

    Remove TEV, put the piston that came with the ID...

    Remove TEV, put the piston that came with the ID coil then see what happens to your pressures then take it from there. If you decide to go to the TEV afterwards, get a OEM value.

    How did he...
  23. How is your lineset run? Is there any chance they...

    How is your lineset run? Is there any chance they can remove any clamps holding the lineset so where it can be moved out while still attached to the coil, whereas they can slide out the coil and R&R...
  24. Doubt he will give you a matched AHRI number with...

    Doubt he will give you a matched AHRI number with the Trane furnace as already mentioned by BaldLoonie. To me he can give a educated guess at what your SEER, EER and HSPF will be. Maybe they can...
  25. Not saying it’s a bad thing but, What’s your take...

    Not saying it’s a bad thing but, What’s your take on Made/Manufactured in China, as the Bosch comes from there.

    “ I'd really like to get back to that and hopefully get some advise on what I...
  26. BTW what is that ( looks like a single droplet )...

    BTW what is that ( looks like a single droplet ) in the 1st photo near the edge of the condenser pad ( to the right of the metal tie down ) looks odd all by itself..looks like a similar composition?
  27. Possibly it’s from left over soap suds or flux...

    Possibly it’s from left over soap suds or flux that never got cleaned up, as that also turns copper a greenish color?

    Anyway did you look inside of the OD unit for any residue on the base plate?
    ...
  28. Goodman? Chances its part of the manufacturing...

    Goodman? Chances its part of the manufacturing process for the sheet metal. Look inside the unit base pan with a strong flashlight around the compressor. Draining out of the weep holes on base pan...
  29. http://aspenmfg.com/documents/faq/12.24-Install%20...

    http://aspenmfg.com/documents/faq/12.24-Install%20Charge.pdf

    Says Add refrigerant until the subcooling measured at the outdoor unit liquid line matches the subcooling from the condenser...
  30. Replies
    4
    Views
    319

    Sooo what do you have, a split system or a...

    Sooo what do you have, a split system or a packaged one piece system? If packaged system, they usually top off at SEER rating much lower than split systems. I think packaged units in general top off...
  31. The 1st quote says LC42/60 that means the coil is...

    The 1st quote says LC42/60 that means the coil is rated from 3.5-5 tons not 2 tons..believe the Y after 42/60 stands for 21” wide cased coil.

    “ Option 1:
    Furnace Model# ML180UH110XE60C Evaporator...
  32. There isn’t a match for quote 3 quote 2 is this...

    There isn’t a match for quote 3 quote 2 is this one I believe. I do not know what HC means before that model number of the coil, as when you enter it along with the number for the coil it kicks it...
  33. Replies
    25
    Views
    871

    Lost 5 lbs of refrigerant or dropped 5 psi? If...

    Lost 5 lbs of refrigerant or dropped 5 psi? If your Tech. Identified the leak(s) even with a electronic, didn’t the Tech. show you exactly where the leak(s) where located?

    I personally don’t...
  34. Replies
    12
    Views
    4,746

    Patent it and come up with a catchy name for it...

    Patent it and come up with a catchy name for it and trademark the name :whistle:

    In all seriousness that’s a good idea...
  35. Keep us posted,.... BTW the blower motor says...

    Keep us posted,....

    BTW the blower motor says High Efficiency EC

    http://mesteksa.com/fileuploads/Literature/SpacePak/SD-ESP-J-0317.pdf
  36. Looks like the Space Pak comes with a paltry 5...

    Looks like the Space Pak comes with a paltry 5 years warranty on the Air Handler. Most Air Handlers ( once registered come with the standard 10 year parts warranty) I do not know know what your...
  37. Post the correct model numbers of the indoor and...

    Post the correct model numbers of the indoor and outdoor section. Easily give you the SEER and EER,..if it’s a matched system....

    There are several ways to increase the SEER, some way is...
  38. How did you make out with everything, from the...

    How did you make out with everything, from the condensate drain to the filter rack gap to the cased coil orientation?
  39. Replies
    39
    Views
    1,781

    You going to register the coil? as guessing the...

    You going to register the coil? as guessing the other one was never registered as you never mentioned that it had a up to 10 year warranty...
  40. Maybe it’s your ductwork layout or balancing or...

    Maybe it’s your ductwork layout or balancing or duct size is not correct for a 5 ton system, or not enough CFM in particular areas as an example.

    Free load calculation https://www.loadcalc.net/
  41. What’s the model numbers of the indoor coil of...

    What’s the model numbers of the indoor coil of option 2 and 3

    Here’s your AHRI certificate for the option 1 gives 15 SEER and 12.5 EER on paper. At least the Contractor is bidding matched...
  42. “What I want to know is if it's worth 14 SEER to...

    “What I want to know is if it's worth 14 SEER to 16 SEER upgrade?”

    You didn’t mention the furnace? If your going to keep it for many years, may want to go with the 14-15 SEER system, as you...
  43. BTW,Bazooka Joey, The high side will be lower...

    BTW,Bazooka Joey,
    The high side will be lower indeed,but the low side(which is the one that is mostly used in resident AC)will be higher when the unit is off(equal pressure).[/QUOTE]

    I did say...
  44. For the most part remove when unit is off and...

    For the most part remove when unit is off and pressures are lower...
  45. Replies
    9
    Views
    315

    https://ahridirectory.org/Home/Download?ReferenceI...

    https://ahridirectory.org/Home/Download?ReferenceId=sUzbLVC3/aFB9wkj0dGAH0Chy1XwrlYbfUEQbM+3xMugucRGy1AcyXY8NlPlmgW+

    If they quoted the same ID coil as the Heat Pump quote here’s the current...
  46. Replies
    9
    Views
    315

    https://ahridirectory.org/Home/Download?ReferenceI...

    https://ahridirectory.org/Home/Download?ReferenceId=sUzbLVC3/aFB9wkj0dGAHyTb/fekrSV0llMBopyGl1JsJq3fH0U00uO0E458A53x
    ...
  47. https://ahridirectory.org/Home/Download?ReferenceI...

    https://ahridirectory.org/Home/Download?ReferenceId=sUzbLVC3/aFB9wkj0dGAH0Chy1XwrlYbfUEQbM+3xMtS1dUHCzdp1bq/fZGco23L

    Any rebates from your state or local utility company or gas company?

    One...
  48. Replies
    15
    Views
    1,360

    Looks like something out of the Twilight Zone...

    Looks like something out of the Twilight Zone with those two pieces of equipment ( rear and foreground ) :whistle:
  49. Replies
    1
    Views
    563

    “ MY QUESTION IS, IF THE TWO SYSTEMS ARE...

    “ MY QUESTION IS, IF THE TWO SYSTEMS ARE MISMATCHED. WHAT NEEDS TO BE REPLACED? IS SOMETHING ELSE CAUSING THESE ERRORS. ? “

    https://www.theacoutlet.com/documents/Specsheet-Goodman-GSZC18.pdf
    ...
  50. Replies
    19
    Views
    696

    https://ahridirectory.org/Home/Download?ReferenceI...

    https://ahridirectory.org/Home/Download?ReferenceId=sUzbLVC3/aFB9wkj0dGAH+QNiZQ9Mjc2dk8dJ68nRDWUXBVNzclDK14mMWK06Nho
    ...
Results 1 to 50 of 1000