Search:

Type: Posts; User: Snapperhead

Page 1 of 20 1 2 3 4

Search: Search took 0.11 seconds.

  1. Replies
    309
    Views
    4,705

    he wont share some of his moving targets ? Oh...

    he wont share some of his moving targets ? Oh Come On Dad !
  2. Replies
    309
    Views
    4,705

    The video of Floyds brother crying about his...

    The video of Floyds brother crying about his death said he was killed over a forgery. So I assume he stole someones check book.
  3. Replies
    309
    Views
    4,705

    [QUOTE=Hugh B;25873992]I told my wife this same...

    I told my wife this same thing yesterday ....

    George should have laid there calm like a good little theif .... and he would be alive today

    Dudes got 18 prior charges , what the hell are the...
  4. Replies
    309
    Views
    4,705

    Heres my opinion ..... dont do stupid sh*T to get...

    Heres my opinion ..... dont do stupid sh*T to get yourself arrested

    This goes for ANY color of skin
  5. Replies
    309
    Views
    4,705

    I dunno man , we never get the whole story of...

    I dunno man , we never get the whole story of whats going on , and why they didnt let him up

    If someone cant breathe .... how do they keep taking breaths and yelling "I cant breathe" ......for 10...
  6. Thread: Capacitor

    by Snapperhead
    Replies
    9
    Views
    469

    Mars2 are made in mexico , and they arent too bad

    Mars2 are made in mexico , and they arent too bad
  7. Replies
    53
    Views
    2,902

    If you move the coil , be careful where you put...

    If you move the coil , be careful where you put it

    You need plenty of air flowing through it

    different parts of the vehicle have positive and negative air pressure

    Take a pick-up truck for...
  8. Replies
    27
    Views
    811

    still has original fans ... I swear man ,...

    still has original fans ...

    I swear man , Rheem and Ruud made some good sh8t 20 years ago

    AmRad has gained much respect as well
  9. Replies
    27
    Views
    811

    Anyone use BMI ? Also USA made with 5 yr...

    Anyone use BMI ?

    Also USA made with 5 yr warranty
  10. Replies
    27
    Views
    811

    40 Cap reading 35 MFD after 20 years

    Leave it .... or replace it with something made in todays times

    10 percent is 4

    40 -4 is 36 ....so going by the nominal rating its not far off

    Hmm ....

    Is AmRad still made just as good...
  11. Dear Mr Home Owner , get 3 quotes from local...

    Dear Mr Home Owner , get 3 quotes from local small businesses , and go with the middle quote


    Ok Joonas .... start signing us those checks

    Make mine the $150 one ...
  12. Replies
    14
    Views
    360

    thats because you are getting older and a tiny...

    thats because you are getting older and a tiny bit rusty ...
  13. Replies
    9
    Views
    272

    I dont think I'd remove the foil ..... but you...

    I dont think I'd remove the foil ..... but you can certainly wrap with more insulation all day long
  14. Replies
    18
    Views
    491

    My sniffer hasnt come out its case in 3 years ,...

    My sniffer hasnt come out its case in 3 years , it drives me Nuts

    If I dont see oil residue outdoors , or on the line set brazes , line set isn't rubbing anywhere , shraders dry , its in the evap...
  15. Replies
    14
    Views
    360

    Ranco A12-1506 shove the bulb in the middle of...

    Ranco A12-1506

    shove the bulb in the middle of coil

    it wont ice up with this stat

    Wire up evap fans to stay on
  16. Replies
    12
    Views
    301

    unless you have some sorta fan control for 63...

    unless you have some sorta fan control for 63 degree weather .... id walk away for now and come back when its 80
  17. good , you won't have to worry about it "single...

    good , you won't have to worry about it "single phasing" and burning up
  18. Replies
    10
    Views
    333

    if its a cap tube that rubbed , or a braze joint...

    if its a cap tube that rubbed , or a braze joint cracked, yes easy fix , but if the tubes leak for no apparent reason .... I dont bother
  19. sounds like you did the right tests If you...

    sounds like you did the right tests

    If you performed the same tests and the fan wont come on ..... something might have burned up in the AH
  20. Replies
    3
    Views
    335

    Yea ofcourse its brazed on I will find a...

    Yea ofcourse its brazed on

    I will find a aftermarket sensor that drops out at 70 , and add use the test port thats nearby

    For now bypassed it
  21. Replies
    3
    Views
    335

    YC090C00A2AAA5. Low pressure cut out

    York split system

    Giving a low pressure fault when 86 deg outside

    Im here now with 76 deg outside , and i watched it turn off with low side reading 110 psi ... does anyone know what the low...
  22. Condensate drains on Rooftops , why cant water hit the roof ?

    I see some buildings where they have pvc pipe from each RTU running across the roof to a gutter OR others will even have drain traps go straight down into the roof Via pitch pocket , into the...
  23. Replies
    1,954
    Views
    34,346

    Unless you bought a mask designed specifically to...

    Unless you bought a mask designed specifically to filter out "Viruses" you are wasting your money , and risking getting sick

    Those masks everyone are buying cant even keep out R22 gas ... or even...
  24. Replies
    28
    Views
    962

    Dude ... Long time ago my high side gauge went...

    Dude ...

    Long time ago my high side gauge went bad , and it was showing 100 psi higher than normal

    So on a R22 system it would show 325

    I washed the condenser really good , looked for fan...
  25. Replies
    28
    Views
    962

    Here is what I would do Try running unit...

    Here is what I would do

    Try running unit without that new dryer

    If runs the same ... now the fun begins

    Cut the lineset at both ends

    Blow with your mouth ... through the lines to see if...
  26. Replies
    36
    Views
    1,116

    ones with a accumilator I charge it wide open...

    ones with a accumilator I charge it wide open throttle
  27. Replies
    6
    Views
    323

    Mom n pop burger joint

    Mom n pop burger joint
  28. Replies
    6
    Views
    323

    IceOmatic slime in drain

    What causes almost clear like gel to form in bin drain , causing it to clog and hold water in bin.

    I cleaned it out about 6 months ago and its clogged again
  29. Replies
    20
    Views
    816

    yup , Ive had a couple grand worth stolen before...

    yup , Ive had a couple grand worth stolen before , and window repair as well

    Calling the cops is a waste of time , unless your insurance will cover some
  30. I doubt it has a thermistor too ... BMW and...

    I doubt it has a thermistor too ...

    BMW and Mercedes might
  31. its been 20 years since i messed with Vehicular...

    its been 20 years since i messed with Vehicular AC

    First .. make sure the "cabin air filter " is clean

    But if chevy is the same as its always been .... your compressor should cycle off the...
  32. We been dumping taxes into the system, why not...

    We been dumping taxes into the system, why not get some back once in while
  33. Soc Sec was designed to never be used ??

    I was listening to a financial advisor this morning who was saying back in 1935 when Social Security was invented , it would be available when you turn 65 years old, but the average life expectancy...
  34. I like the sticker on the right side .... "use...

    I like the sticker on the right side .... "use circuit breaker or time delay fuse"

    Well gee thanks for the advise .... because I was about to toss a line up the telephone pole
  35. Yep , its odd how they didnt put maximum ampacity...

    Yep , its odd how they didnt put maximum ampacity , or even a suggestion

    I looked all over 5 coolers , no stickers anywhere

    The owner was like .... man I just dont have the money right now to...
  36. it has a 30 second delay for 2nd , and each...

    it has a 30 second delay for 2nd , and each compressor pulls 10 RLA 55 LRA
  37. Cooler single phase 120V pulling 24Amps

    Ive never seen one of these before ( 120V with 2 compressors )

    Customer just 5 got from auction

    Building has 20A breakers on regular recs, but it trips them after a while

    ( the units...
  38. If you wear a size 10 sneaker , and you find some...

    If you wear a size 10 sneaker , and you find some 9.5's for a really good deal , sure they might work .... but not very good over time

    At first they might feel tolerable ... but after a while your...
  39. 10 percent fresh air....

    10 percent fresh air....
  40. Yea I have 2 friends 6 ft under .. one had 5 kids...

    Yea I have 2 friends 6 ft under .. one had 5 kids , other had 3
  41. Replies
    17
    Views
    1,164

    now thats funny i dont care who you are .....

    now thats funny i dont care who you are .....
  42. well .... now theres drug addicts mom shes...

    well .... now theres drug addicts mom

    shes going to cling to the 3 year old because thats all she has left of a small piece of her son

    Hopefully you get along with her ..... ?
  43. the kid will have no idea who that man was .... ...

    the kid will have no idea who that man was ....

    I cant believe your daughter got so lucky , usually mean/worthless people live forever
  44. Thread: Moms house

    by Snapperhead
    Replies
    13
    Views
    1,791

    you dont run into refrig issues when doing the...

    you dont run into refrig issues when doing the larger AH with a HP ?
  45. and ... you can always go up a little with "start...

    and ... you can always go up a little with "start caps"

    If theres a 250-280 on the unit and you only have a 280-325 , throw that bad boy on there for now
  46. I dont remember the "exact" numbers ... but i...

    I dont remember the "exact" numbers ... but i carry a few around 88-125 and 180-225 and 250- 280 and 250-325 and 330-400

    Plus you can add a couple together if needed
  47. he evidently sees alot of choo choo trains

    he evidently sees alot of choo choo trains
  48. pay attention to the caps you come across and...

    pay attention to the caps you come across and write them down.

    Get a couple to carry ... along with a supco "SUPR" Relay

    That relay is universal and will buy you plenty of time until you...
  49. Ive changed a bunch to 407c and never touched the...

    Ive changed a bunch to 407c and never touched the oil ....
  50. Replies
    34
    Views
    1,520

    Well , since its "low voltage" , I guess we can...

    Well , since its "low voltage" , I guess we can say check from C to Y coming into the board from t-stat to know if its calling

    And Larry , Although you "can" check R to Y ..... you are back...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4
Contracting Business
HPAC Engineering
EC&M
CONTRACTOR