Search:

Type: Posts; User: FreeThrowGuy

Page 1 of 2 1 2

Search: Search took 0.02 seconds.

  1. Thread: Filters

    by FreeThrowGuy
    Replies
    16
    Views
    897

    Not a fan of the 3m filtretes Also I don't...

    Not a fan of the 3m filtretes

    Also I don't base restrictions on audible sounds. Run an eternal static pressure test with various filters on your own system and find out what you like best..

    Let...
  2. Replies
    25
    Views
    902

    Portland, Oregon is strict on inspections. It...

    Portland, Oregon is strict on inspections. It definitely wouldn't cut it in the area he installed. - - it's a "side job" and it's for a grow room, so there wasn't even a chance he was going to pull a...
  3. Replies
    25
    Views
    902

    I live in Portland as well. I only trust VRF when...

    I live in Portland as well. I only trust VRF when it comes to grow rooms. High heat loads due to lighting and lots of humidity to remove when they are constantly watering plants.

    I wish the best...
  4. Replies
    3
    Views
    361

    Brown-Yellow are PW wires Orange-Brown are RPM...

    Brown-Yellow are PW wires

    Orange-Brown are RPM feedback wires

    They will be VDC readings. I don't know if I can give specific ratings so I'll let one of the pro members give them if they feel...
  5. Replies
    3
    Views
    361

    Works like every other variable speed motor or...

    Works like every other variable speed motor or PWM motor on the market.

    Due to the amount of issues with plugged secondary heat exchangers with these units, I'm sure the guys on the site are going...
  6. Good read though. Thanks for posting Sent...

    Good read though. Thanks for posting

    Sent from my LM-G710VM using Tapatalk
  7. Let them close them. We will be back for low air...

    Let them close them. We will be back for low air flow issues and bad blower motors

    Unless they are cool customers then I'll tell them

    Sent from my LM-G710VM using Tapatalk
  8. Sounds like you miswired it after you installed...

    Sounds like you miswired it after you installed the heat exchanger. Did you pull out the schematic after you got that error code?

    There could obviously be something else wrong but that would be...
  9. Replies
    18
    Views
    883

    Ball bearings last at higher temperatures but can...

    Ball bearings last at higher temperatures but can be loud af on start up. If you live in a colder climate use sleeve bearing in my opinion

    Sent from my LM-G710VM using Tapatalk
  10. Replies
    18
    Views
    883

    In your area sure. Try out some sleeve bearing...

    In your area sure. Try out some sleeve bearing motors in Arizona, Texas, Florida and let me know how that goes for you [emoji6]

    Sent from my LM-G710VM using Tapatalk
  11. This Sent from my LM-G710VM using Tapatalk

    This

    Sent from my LM-G710VM using Tapatalk
  12. Yes Ryan, did you grab your gauges or your wire...

    Yes Ryan, did you grab your gauges or your wire strippers?

    Sent from my LM-G710VM using Tapatalk
  13. Replies
    18
    Views
    883

    I prefer century motors (don't forget to pull the...

    I prefer century motors (don't forget to pull the drain plug) they are generally 1/3-1/8 HP.

    I carry an 825 RPM and a 1100 RPM. Very few times where those motors can't do the job

    Sent from my...
  14. So if it was a variable speed inducer motor and a...

    So if it was a variable speed inducer motor and a modulating gas valve that was converted to propane.. there would be little-to-no efficiency loss for converting?

    I'm curious.. Not trying to test...
  15. Thread: frplce

    by FreeThrowGuy
    Replies
    7
    Views
    452

    Pop off your manifold side at the gas valve,...

    Pop off your manifold side at the gas valve, clear it with nitrogen, confirm you have 3.5 inWC, add embers (help move the flame along) and make sure your fuel/air ratio is set properly. That's about...
  16. Thread: frplce

    by FreeThrowGuy
    Replies
    7
    Views
    452

    Sounds like a DIYer. That's why I didn't suggest...

    Sounds like a DIYer. That's why I didn't suggest this first [emoji23]

    Sent from my LM-G710VM using Tapatalk
  17. Thread: frplce

    by FreeThrowGuy
    Replies
    7
    Views
    452

    What was your manifold gas pressure? Sent...

    What was your manifold gas pressure?

    Sent from my LM-G710VM using Tapatalk
  18. Replies
    8
    Views
    616

    240 PSI for 410A is roughly 80 degrees...

    240 PSI for 410A is roughly 80 degrees Fahrenheit..

    Your suction temp is 113 degrees?

    Something ain't right

    I'm with the low on charge assumption

    Sent from my LM-G710VM using Tapatalk
  19. Replies
    11
    Views
    701

    ^ there's your educated answer Sent from my...

    ^ there's your educated answer

    Sent from my LM-G710VM using Tapatalk
  20. Replies
    11
    Views
    701

    I would check in the manual with the product you...

    I would check in the manual with the product you are about to install to see which linesets are approved for what length. If you can't find it call tech support and get an answer

    Or

    You can...
  21. Yeah I know service technicians and installers...

    Yeah I know service technicians and installers that have my back. The issue with Arizona specifically is electric is so costly. I was paying between $500-600 in electricity/monthly to cool 2800 sqft....
  22. Investment property. I'm doing it for resale...

    Investment property. I'm doing it for resale value because I can get them at a discounted rate and I know good installers that can take care of it for me.

    Basically I can spend $5-6k and raise...
  23. Think I'm better off sticking with an XV? Sent...

    Think I'm better off sticking with an XV?

    Sent from my LM-G710VM using Tapatalk
  24. Bryant variable speed heat pump question

    Will Bryant variable speed heat pumps hold up in the Phoenix area?

    I'm a service technician that owns a rental house in Phoenix and I'm currently working in Oregon.

    I want to install new heat...
  25. Replies
    17
    Views
    1,094

    I feel like this will fall on the pro membership...

    I feel like this will fall on the pro membership side.

    I'm interested as well and want to know the answer

    Sent from my LM-G710VM using Tapatalk
  26. Replies
    16
    Views
    804

    I just moved back to Oregon from Phoenix AZ. I...

    I just moved back to Oregon from Phoenix AZ. I feel like i haven't been able to feel my toes in three weeks [emoji854]

    At least I haven't had to replace a compressor since I've been back (knock on...
  27. How many elbows/90s are there between the...

    How many elbows/90s are there between the condenser and wall?

    Sent from my LM-G710VM using Tapatalk
  28. Replies
    4
    Views
    487

    Why can't you just buy a regular supply plenum...

    Why can't you just buy a regular supply plenum and install your own start collars and dampers?

    As far as air flow and lowering static pressure.. Air flow is tough man. I'd recommend taking an air...
  29. Replies
    14
    Views
    1,243

    Are the service valves open? Lol Fixed orifice...

    Are the service valves open? Lol

    Fixed orifice or TXV?

    Which way is your filter drier arrow pointing?

    I'd start with the basics

    Sent from my LM-G710VM using Tapatalk
  30. Replies
    28
    Views
    3,572

    Nope I got my nate a few years back when I was in...

    Nope I got my nate a few years back when I was in Oregon.

    And btw this Phoenix market is the worst working conditions I've ever seen.

    No inspections, nothing is to code, 65-80 hour work weeks,...
  31. Replies
    28
    Views
    3,572

    I failed core my first time around because it's...

    I failed core my first time around because it's all the weird OHSA and department of transportation questions lol if you have been in the field you should pass the specialty tests with flying colors....
  32. Replies
    22
    Views
    1,475

    In my opinion, if you were to do a compressor or...

    In my opinion, if you were to do a compressor or condenser coil (you can't pump down and you're forced to recover), it is good practice to completely removed the filter drier from inside the...
  33. Replies
    40
    Views
    15,647

    I was just curious on your opinion. Good response...

    I was just curious on your opinion. Good response

    Sent from my LM-G710VM using Tapatalk
  34. Replies
    40
    Views
    15,647

    How do you feel about surge protectors when it...

    How do you feel about surge protectors when it comes to true variable speed systems that have rather expensive circuit boards in the condenser?

    Sent from my LM-G710VM using Tapatalk
  35. Replies
    40
    Views
    15,647

    Found one myself in Phoenix this week808313 ...

    Found one myself in Phoenix this week808313

    Sent from my LM-G710VM using Tapatalk
  36. Replies
    37
    Views
    2,109

    If they are relief dampers like trane has done...

    If they are relief dampers like trane has done with their variable speed communicating system.. Wouldn't be surprised. Bypass is a giant waste

    Sent from my LM-G710VM using Tapatalk
  37. Replies
    46
    Views
    2,132

    You need to look at the schematic and follow Y....

    You need to look at the schematic and follow Y. It has all the answers

    Sent from my LM-G710VM using Tapatalk
  38. Replies
    46
    Views
    2,132

    You need to look at your schematic and figure out...

    You need to look at your schematic and figure out what's in between your incoming Y and your contactor. Let me know the answer...

    Also...

    What terminals are receiving 24v outside? Is your...
  39. Replies
    46
    Views
    2,132

    That board isnt powered by high voltage Sent...

    That board isnt powered by high voltage

    Sent from my LM-G710VM using Tapatalk
  40. Replies
    46
    Views
    2,132

    The same way you reset everything else in life....

    The same way you reset everything else in life. Power off/power on

    Sent from my LM-G710VM using Tapatalk
  41. Replies
    46
    Views
    2,132

    Go find/fix your leak, charge system and reset...

    Go find/fix your leak, charge system and reset your board. Have a good day

    Sent from my LM-G710VM using Tapatalk
  42. Replies
    46
    Views
    2,132

    Sounds like we fixed your defrost problem too....

    Sounds like we fixed your defrost problem too. I'll let the other guys respond

    Sent from my LM-G710VM using Tapatalk
  43. Replies
    46
    Views
    2,132

    Did you hook up your gauges today by any chance? ...

    Did you hook up your gauges today by any chance?

    Sent from my LM-G710VM using Tapatalk
  44. Replies
    88
    Views
    2,322

    End post before we offend each other lol Sent...

    End post before we offend each other lol

    Sent from my LM-G710VM using Tapatalk
  45. Replies
    88
    Views
    2,322

    I would never get an abortion myself, that's just...

    I would never get an abortion myself, that's just how I am. I always vote to keep abortion legal so women have the ability to make the choice themselves. However, 9 months, man that's effing brutal....
  46. Replies
    8
    Views
    533

    It almost feels like a high schooler wrote this...

    It almost feels like a high schooler wrote this for his English class

    Sent from my LM-G710VM using Tapatalk
  47. Replies
    32
    Views
    2,407

    I've heard of people doing it on flared fittings....

    I've heard of people doing it on flared fittings. If you didn't blatantly pour it in the lineset I'm sure you're fine.

    See what others have to say about it though

    Sent from my LM-G710VM using...
  48. Replies
    38
    Views
    2,540

    It's non stop in Phoenix AZ. The land of aluminum...

    It's non stop in Phoenix AZ. The land of aluminum linesets and horrible ductwork.

    I haven't even heard of a city inspection here

    Sent from my LM-G710VM using Tapatalk
  49. Replies
    38
    Views
    2,540

    Is the indoor air handler a match for the...

    Is the indoor air handler a match for the condenser? I'm thinking overcharged as well. - - any chance a company could have came out in summer with an undertrained technician that misdiagnosed an...
  50. Replies
    50
    Views
    2,360

    My exact thought. OP when you go back we will...

    My exact thought.

    OP when you go back we will need:

    Temp rise (supply air temp minus return air temp)
    Manifold gas pressure
    Blower speed
    static pressure (before and after the coil if...
Results 1 to 50 of 71