Search:

Type: Posts; User: dandyme

Page 1 of 20 1 2 3 4

Search: Search took 0.09 seconds.

  1. When the need arises for a service call again;...

    When the need arises for a service call again; when you place that call, ask the perspective organization if their technicians have adequate test instruments. Unless a LOT was left out of your...
  2. Replies
    1
    Views
    130

    ....and what kind of webinar or virtual event is...

    ....and what kind of webinar or virtual event is this???
  3. Replies
    16
    Views
    782

    Is this a GEMINI unit?

    Is this a GEMINI unit?
  4. Thread: New here

    by dandyme
    Replies
    7
    Views
    791

    I want to know what is the prize since this is in...

    I want to know what is the prize since this is in CONTEST! CONTEST!?
  5. Replies
    23
    Views
    470

    "AC Ready Kit", that's a different name for it....

    "AC Ready Kit", that's a different name for it. Please tell us the tech didn't call it that.
  6. thought they stated #1 is on, oh well.

    thought they stated #1 is on, oh well.
  7. The manual indicates that when switch #! is in ON...

    The manual indicates that when switch #! is in ON position, the unit is in EMERGENCY HEAT, your electric heat is the only heat operating.
  8. Replies
    2
    Views
    423

    Didn't read the rules you agreed to when signing...

    Didn't read the rules you agreed to when signing onto site did you.
    Pricing NOT ALLOWED.
  9. Are you sure that #1 compressor is capable of...

    Are you sure that #1 compressor is capable of operating?
  10. Replies
    22
    Views
    874

    Here daily mostly. Discouraging to see the newer...

    Here daily mostly. Discouraging to see the newer "techs" have no inkling how to troubleshoot, but have no problem coming here and wanting solution to their problem, almost like a homeowner. These...
  11. acetylene above 15# psi will try to come out as a...

    acetylene above 15# psi will try to come out as a liquid, EXPLOSIVE.
    my normal set up: oxy 10-15# unless cutting tip in use, acty: no more than 7#.

    If you are ever really bored, inflate a balloon...
  12. Replies
    50
    Views
    2,519

    Because we don't like you. :spitball::gah::beat:

    Because we don't like you. :spitball::gah::beat:
  13. Thanks for the heads up. #BringBackCoolKwiz

    Thanks for the heads up.
    #BringBackCoolKwiz
  14. Is this unit under warranty??? If yes, call your...

    Is this unit under warranty???
    If yes, call your installer and stop playing with things that may hurt you.
    If no, call a service company if you have "issues" with installing contractor.
  15. Replies
    10
    Views
    1,175

    Poor thing was tired and needed a nap.

    Poor thing was tired and needed a nap.
  16. Replies
    7
    Views
    658

    Same effect. Pressure differential. Never seen...

    Same effect. Pressure differential. Never seen mono flo tee for cast iron.
  17. Replies
    32
    Views
    2,778

    Unless that is the exterior wall? "This...

    Unless that is the exterior wall?
    "This accessory must be used only for terminating the vent of a Category IV furnace. Do not use this termination kit for any other type furnace. Failure to follow...
  18. Replies
    24
    Views
    1,602

    1-why is the pressure "creeping up" once the...

    1-why is the pressure "creeping up" once the solenoids open?
    2-just what kind of time delay between contactors pulling in?
  19. Replies
    6
    Views
    330

    Is the system NOT under warranty?

    Is the system NOT under warranty?
  20. If a job is posted and one wants to know the...

    If a job is posted and one wants to know the answers to those questions; if one was motivated enough they would contact the party posting the job.
    So many times I've notified someone of a job...
  21. 1-Did not see design conditions? 2-Does it get...

    1-Did not see design conditions?
    2-Does it get below freezing?
    2a-Did mfg remove criteria of insulating venting in area subject to freezing temps?
    2b-Is that drain line going to be insulated/heat...
  22. Replies
    10
    Views
    432

    The equipment will have to rated for manufactured...

    The equipment will have to rated for manufactured housing unless your duct work is replaced.
    Coleman is rated, trane was at one time, there are probably others.
  23. Replies
    12
    Views
    1,051

    are those 2 questions your addy? otherwise, did...

    are those 2 questions your addy?
    otherwise, did not see it.
  24. Replies
    12
    Views
    1,051

    you've got mail

    you've got mail
  25. Replies
    28
    Views
    1,824

    WD-40, rags... spray that shaft, wipe the crud...

    WD-40, rags... spray that shaft, wipe the crud off of it.
    60 grit sandpaper.
    WD-40, hammer on everything, might want to have ear plugs at this point.
    repeat any and all steps necessary.
  26. Replies
    2
    Views
    550

    So, you're soliciting to be a qualifier?

    So, you're soliciting to be a qualifier?
  27. Replies
    28
    Views
    1,283

    Well, how is the 3 legged turkey farm out by the...

    Well, how is the 3 legged turkey farm out by the nuclear plant doing?
  28. Replies
    7
    Views
    649

    That air handler number is deceptive in its...

    That air handler number is deceptive in its presentation. the "60" is it's MAX capacity. you have got to get the number off the coil itself to verify coil size.
    That is a but load of moisture on the...
  29. A business owner does not have to licensed, BUTT...

    A business owner does not have to licensed, BUTT the company HAS to have a licensed full time employee in order to be a contractor. The license covers INSTALLATION. A service only HVAC company needs...
  30. Replies
    10
    Views
    582

    It identifies as a heater :eek::toetap::oops:

    It identifies as a heater :eek::toetap::oops:
  31. Replies
    2
    Views
    549

    is the thermostat not wired to power the...

    is the thermostat not wired to power the reversing valve?
  32. Replies
    6
    Views
    614

    That hurt to read. Can only hope your verbal...

    That hurt to read.
    Can only hope your verbal communication is somewhat better than your written.
  33. Replies
    5
    Views
    732

    I was of the understanding that 3rd party...

    I was of the understanding that 3rd party automation networks did not play well with VRV/VRF systems. Or have a I missed the latest info?
  34. Replies
    6
    Views
    476

    Why not ask your neighbor who they recommend?

    Why not ask your neighbor who they recommend?
  35. That looks to be a small rosebud tip. It that...

    That looks to be a small rosebud tip.
    It that payson that was here several years back?
  36. Replies
    17
    Views
    927

    Is this a vrf? did you move the little jumper at...

    Is this a vrf?
    did you move the little jumper at the top of pcb board to new board?
    just what was the error code originally?
  37. Replies
    16
    Views
    567

    If you're adding load you better check the duct...

    If you're adding load you better check the duct design.
    You can just rob peter to pay paul.
  38. Replies
    28
    Views
    1,337

    1-are the tech's from the installing contractor?...

    1-are the tech's from the installing contractor?
    2-jumping to different service contractor each service call is doing nothing for you because each time the new tech is starting from ground zero and...
  39. Replies
    13
    Views
    979

    Operating Sequence COOLING, UNITS WITHOUT...

    Operating Sequence COOLING, UNITS WITHOUT ECONOMIZER — When thermostat calls for cooling,terminals G andY1areenergized. The indoor-fan contactor (IFC) and compressor contactor are energized and...
  40. Replies
    0
    Views
    597

    Winston-Salem NC

    Hiring residential service techs.
    www.Loganhvac.com
  41. Replies
    7
    Views
    431

    TXV? slow to respond? occasionally shutting...

    TXV?
    slow to respond?
    occasionally shutting down?
  42. Replies
    2
    Views
    272

    " I check all power and all is good, 120v each...

    " I check all power and all is good, 120v each leg both pre and post" enlighten me as to what that means.
    Where are you checking power at & to?
    "pre & post" what?
  43. Thread: Crane signals

    by dandyme
    Replies
    9
    Views
    1,247

    Seems about accurate.:bsing:::DD:

    Seems about accurate.:bsing:::DD:
  44. Replies
    3
    Views
    237

    1-make certain you don't have filter(s) elsewhere...

    1-make certain you don't have filter(s) elsewhere in the return.
    2-sounds like the drain trap is dry (if there is a trap).
  45. Replies
    20
    Views
    2,647

    When it was level, that poor goodman was doomed...

    When it was level, that poor goodman was doomed from the start.
  46. Replies
    5
    Views
    582

    www.heatingandcoolingservicesinc.com call these...

    www.heatingandcoolingservicesinc.com
    call these guys if you haven't already. have no idea if they service your area but there is a better than average chance.
  47. Don't let the terms get in the way of...

    Don't let the terms get in the way of understanding.
    With a "gas pack" "duel fuel" refers to gas & electricity.
    A TRUE duel fuel package unit will be a package heat pump with gas heat (instead of...
  48. Replies
    21
    Views
    1,511

    As stated previously; the thermostat is no more...

    As stated previously; the thermostat is no more than a switch. You CANNOT read a closed switch.
  49. Solid numbers whether facual or fictional is what...

    Solid numbers whether facual or fictional is what decisions are made on. Help us help you, we have no crystal ball. Are the pressures steadily climbing or are they bouncing? With a 600# trip, lets...
  50. Replies
    5
    Views
    722

    Fieldpiece makes a set that has leads, clips,...

    Fieldpiece makes a set that has leads, clips, standard tips & needle tip that slip onto leads for just a little more than those fluke needles cost. Or use paperclips.
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4