  1. Replies
    9
    Views
    120

    Maybe i don't want to know but is that mounted on...

    Maybe i don't want to know but is that mounted on the furnace or the coil housing? If it is that is not usually a good place to mount it. It looks like someone cut the hole in the metal and forgot...
  2. Just a thought here, the systems are several...

    Just a thought here, the systems are several years old on marginal duct work. It would not take that much dust/dirt to plug things to increase that static. As was mentioned a PM could be money well...
  3. Replies
    10
    Views
    195

    A 45 is 15", the main on a wye is 5 and the...

    A 45 is 15", the main on a wye is 5 and the branch is 25 then you have your register boot so you have over 75' TEL it looks like to me and we haven't considered your take off from the plenum or any...
  4. Replies
    10
    Views
    195

    Are you using elbows for register boots cause...

    Are you using elbows for register boots cause most boots have a TEL greater than 75.
  5. It is possibly a wiring issue. If the furnace...

    It is possibly a wiring issue. If the furnace does not have a proper ground you can have intermittent problems often times associated with ignition. It may not be at the furnace but could be...
  6. Replies
    10
    Views
    195

    I assume a 2 T system, I would say the 14" but...

    I assume a 2 T system, I would say the 14" but there is so much more to it than that such as total equivalent length, friction loss, etc. If you are using flex you have about a 20% loss from the...
  7. Just to throw out one other little detail to...

    Just to throw out one other little detail to think about. For a HX to last a long time and not rust or crack the system has to be sized correctly. One of the issues with HX rust is short cycles. ...
  8. Replies
    27
    Views
    474

    You started this post asking about price and you...

    You started this post asking about price and you have gotten many good answers that you need to understand what they are telling you before you proceed. At this time I will not add to what has been...
  9. It sounds to me like for some reason the furnace...

    It sounds to me like for some reason the furnace is not lighting on the first try where the gas valve opens for 4 seconds then closes again in it does not sense flame. Then it goes through a 60...
  10. Replies
    20
    Views
    389

    Pretty much although it is a daily average as...

    Pretty much although it is a daily average as they test it about every minute.
  11. Replies
    13
    Views
    312

    If you don't want to run the heat pump just...

    If you don't want to run the heat pump just switch the thermostat to emergency heat. It shuts off the heat pump and only runs the furnace.

    You can always switch it back as the ODA modulates up.
  12. Replies
    20
    Views
    389

    Your furnace BTU is rated at a specific BTU...

    Your furnace BTU is rated at a specific BTU per/CF or gal of fuel. The typical number for Nat Gas is 1000 BTU/CF. The problem is gas can range in heat content from close to 900 to close to 1100. ...
  13. Suggestion. Put in a Trane TUHM060. The furnace...

    Suggestion. Put in a Trane TUHM060. The furnace modulates to give you the heat you need when you need it. 60 may be slightly over but it will probably never run at max.
  14. Replies
    15
    Views
    373

    Is your drawing to any kind of scale or just a...

    Is your drawing to any kind of scale or just a pencil drawing for a general idea. I ask because by the drawing it appears the duct after the branch is bigger than what is coming from the heater. ...
  15. To say they are worthless is a bit of an...

    To say they are worthless is a bit of an overstatement but if you single out use on Covid 19 I have no argument at this time.

    i have been installing UV lights for years. I agree that care must...
  16. Replies
    16
    Views
    380

    Anyone can make a mistake but that one is a...

    Anyone can make a mistake but that one is a biggie. I don't know if I would want to give them a second chance or not. If they missed an error that big how many small things did they miss also, or...
  17. Replies
    1
    Views
    131

    I have used several brands of UV lights and their...

    I have used several brands of UV lights and their replacement bulbs and have had good luck with all, generally lasting 2 years, all having the 4 pin bulbs except the Honeywell which had a built in...
  18. I put in a lot of Aprilaire air filters. Most of...

    I put in a lot of Aprilaire air filters. Most of my customers can tell a difference but I won’t go as far as to say 100%. To me the design of the Aprilaire media makes a better seal so air has to go...
  19. Anything in writing in the quote or literature,...

    Anything in writing in the quote or literature, ect.

    It sounds like they didn't flow N2 while brazing, didn't do triple evac, didn't take service into consideration, and didn't seal the duct...
  20. Replies
    21
    Views
    534

    Thanks for a final report so we know how things...

    Thanks for a final report so we know how things ended for you. Stop by again if you have more questions.
  21. I didn’t notice before but if the heat pump alone...

    I didn’t notice before but if the heat pump alone can produce 40+ degrees rise you have a problem. They are generally not designed for that kind of rise as it throws the pressures off and will/should...
  22. I have not seen much if any demand for it in my...

    I have not seen much if any demand for it in my residential market. I can kind of see it in a commercial setting but can also see it as an answer looking for a problem. Here is the issue I have...
  23. I am surprised that the installing dealer did not...

    I am surprised that the installing dealer did not relay this to you. Heat pumps will go through defrost every so often depending on conditions which I am sure you already know. When they are in...
  24. Replies
    32
    Views
    1,074

    The only thing I can see on the 'backwards"...

    The only thing I can see on the 'backwards" comment is there are 2 ways to run vent pipe. One is like you have it where the joints run the same direction as the flow so the flue gases stay in the...
  25. Replies
    20
    Views
    546

    Could be, I don't do any of that type of work so...

    Could be, I don't do any of that type of work so i really don't have a clue except it seems they use it to tap water mains.
  26. Replies
    39
    Views
    4,092

    As to the OP I do a load on almost all houses I...

    As to the OP I do a load on almost all houses I bid new or replacement equipment for except those that I have done in the past and the house has not changed. I have run into houses that had 5T and...
  27. Replies
    20
    Views
    546

    That's funny but also true. Dad used to work...

    That's funny but also true.

    Dad used to work for the Gas Co. There were many times where a main would break and it was either work it live or shut the whole town down. They would call in a...
  28. Replies
    10
    Views
    475

    Q1 that will be different for almost every...

    Q1 that will be different for almost every business, there are a lot of niche markets in HVAC as well as business size from 1 to over 1000 employees, working out of their house or in multiple states....
  29. Make enough noise and he will want to leave.

    Make enough noise and he will want to leave.
  30. I think I would agree with the other contractors....

    I think I would agree with the other contractors. A 2" elbow is at best 5', at worst 10', time 4is 20-40' + your 25 and your pushing the envelope. Any restriction in the termination and you have a...
  31. He also didn't ask about using a sails switch or...

    He also didn't ask about using a sails switch or any number of other controls that will do the same thing.
  32. Replies
    20
    Views
    546

    Shut the gas off, blow N2 through the pipe, drill...

    Shut the gas off, blow N2 through the pipe, drill a hole where you need the "T" and have a welder weld a piece of 3/4" pipe threaded on 1 end into the hole. Put a valve on the 3/4 nip and bleed teh...
  33. You can't beat experience, you can't duplicate...

    You can't beat experience, you can't duplicate experience, tools don't help anyone that doesn't understand what the tool is designed to do and why. A tech without a mechanical, critical thinking...
  34. Replies
    21
    Views
    534

    Yes

    Yes
  35. Replies
    21
    Views
    534

    It should be easy to set up the system so the...

    It should be easy to set up the system so the furnace runs during defrost. This way the house doesn’t cool down during defrost and the defrost cycle is faster.
  36. Replies
    21
    Views
    534

    Steam rising is a good clue it was in defrost. ...

    Steam rising is a good clue it was in defrost. If you see it doing this again it should go back to normal operation in 10 minutes or less and it may go into defrost as warm as 40 if other conditions...
  37. Replies
    10
    Views
    475

    Why is it I get the feeling that you do not...

    Why is it I get the feeling that you do not understand the questions you are asking or the people you are asking them to? If you don't understand both of them you won't understand the answers either!
  38. Replies
    21
    Views
    534

    It is not likely that a capacitor will be bad...

    It is not likely that a capacitor will be bad intermittently, but it is possible that the motor will start intermittently with a bad cap. A bad capacitor will cause the motor to draw more amps and...
  39. Replies
    3
    Views
    192

    If the system has not had a leak before why was...

    If the system has not had a leak before why was the coil replaced in 15?

    If it is only a lb or 2 low I would not worry about a leak. if it goes to 3 then replace the system next year instead of...
  40. Replies
    4
    Views
    350

    By my numbers you are still short of air. You...

    By my numbers you are still short of air. You have a 3.5 ton air handler and it is moving around 1100 cfm instead of 1400. Trane recommends 1400 for 20 Kw of electric heat.
  41. Replies
    4
    Views
    352

    I'm a "Lone Wolf", in other words I do everything...

    I'm a "Lone Wolf", in other words I do everything myself from bids, to manual labor, to billing, to the accounting. That is a lot of hats to rotate daily on ones head, so my take may be profoundly...
  42. Replies
    14
    Views
    465

    I started out with a Plano tackle box, it worked...

    I started out with a Plano tackle box, it worked great except it was not built heavy enough so every few (4-7) years I had to get a new one. Then I went to the Veto Tech LT I think. I could not get...
  43. I think what you are missing is a guy that...

    I think what you are missing is a guy that understand airflow. Yes he improved the alignment of the duct but the canvas should only have a little compression to it, you don't want it pulled tight. ...
  44. Here is the problem. If the gas line is too...

    Here is the problem. If the gas line is too small, when you get into a situation where the use is greater than the pipe can carry the pressure of the system drops. This can lead to the appliance not...
  45. Replies
    14
    Views
    354

    I got a can of spray paint, I can make any...

    I got a can of spray paint, I can make any thermostat you want black! or red, green, blue, orange (yuck), purple, pink, maybe even give it that hammered bronze look.
  46. Replies
    58
    Views
    1,311

    Did the thermostat happen to be a Nest?

    Did the thermostat happen to be a Nest?
  47. Replies
    14
    Views
    354

    I like the Trane 824 but it fits well with the...

    I like the Trane 824 but it fits well with the Trane equipment I sell so there is that.
  48. Replies
    6
    Views
    404

    To start with you may want to dig into why the 2...

    To start with you may want to dig into why the 2 rooms are a few degrees off from the rest of the house. Too warm on heating means too much air, too cool means too little. If this is not corrected...
  49. Replies
    33
    Views
    1,059

    I bought them cause there were short/small and it...

    I bought them cause there were short/small and it seemed like I was running into a lot of places where I didn't have the room to swing a regular snip. The more I used them the more places I found...
  50. More than likely it is not going to be big enough...

    More than likely it is not going to be big enough since in general gas pipe is not oversized by 40-60k BTU plus a line to the attic will add a lot of footage from where ever you want to start from. ...