  1. TDR= Time Delay Relay UF= Upflow ? HRZ=...

    TDR= Time Delay Relay

    UF= Upflow ?

    HRZ= Horizontal ?

    Mentions those designation for furnaces also under “ Features and Benefits “
    ...
  2. Replies
    10
    Views
    245

    I was referring to once whomever installs the new...

    I was referring to once whomever installs the new coil to register it or homeowner try to register it. Unless after the paperwork is filed at the distributor and up channeled that coil may follow the...
  3. Replies
    10
    Views
    245

    Price is regional, labor and refrigerant tax...

    Price is regional, labor and refrigerant tax included? If someone came out and looked it over that persons time is added in also. Register the coil, you may get upwards of 10 years, unless that coil...
  4. Replies
    21
    Views
    463

    I wonder if one year workmanship is the same as...

    I wonder if one year workmanship is the same as one year labor? Workmanship to me means they guarantee their braze joints don’t leak as an example when they hook up the lineset, or the field install...
  5. Fried compressor to me means a burnout/acidic...

    Fried compressor to me means a burnout/acidic conditions, mechanical failure is different, if it’s acidic more work is involved cleaning up the system correctly, especially if you only replace the...
  6. Replies
    21
    Views
    463

    That’s a dirt cheap price ( including tax? ) even...

    That’s a dirt cheap price ( including tax? ) even for a bare bone unit, at least where I reside, if a reputable, licensed insured Contractor ( non side job ) installed it. Did you get a labor...
  7. Replies
    2
    Views
    164

    http://yaunco.com/pdfs/rheem/uand_spec.pdf ...

    http://yaunco.com/pdfs/rheem/uand_spec.pdf

    Dated 6/05 page 11 says 1/4” OD is the standard line size for the 18/24/30 units.
  8. Did the Tech. find and repaired the refrigerant...

    Did the Tech. find and repaired the refrigerant leak as far as you know? As you mention the same thing is happening. If itís been repaired, call out a service Tech. Who knows electrical...
  9. https://www.alpinehomeair.com/related/Goodman%20AV...

    https://www.alpinehomeair.com/related/Goodman%20AVPTC%2014%20Series%20Installation%20and%20Operating%20Instructions.pdf

    Page 9 says not to exceed .5” static

    Your OD unit is a ASX16 not ACX16
    ...
  10. Replies
    21
    Views
    463

    What are you asking “ is this OK “ if it’ll...

    What are you asking “ is this OK “ if it’ll work?.....yes, it’s a matched set and registered. An occasional Preventative Maintenance over the life of the system is a nice thing.

    I guess the...
  11. Replies
    21
    Views
    463

    https://www.ahridirectory.org/Home/Download?Refere...

    https://www.ahridirectory.org/Home/Download?ReferenceId=sUzbLVC3/aFB9wkj0dGAH0UU3cDzEMdegSgYP3XRTqPndzVnl+iMRXC0OoweTCTR

    Hereís your AHRI number, looks to be the value line they installed, no...
  12. IMO,.on window units ..Central A/C units get...

    IMO,.on window units ..Central A/C units get higher SEER, due to larger ID and OD coils, TXV metering device, ECM variable speed blower motors or constant torque motors for starters, inverter drive...
  13. Replies
    21
    Views
    463

    Did they just swap the brand without telling you...

    Did they just swap the brand without telling you in advanced?

    Post the model number of the ID and OD sections of both the Trane and Bryant. as at least Bryant has different tier levels of 14 SEER...
  14. https://www.ahridirectory.org/Home/Download?Refere...

    https://www.ahridirectory.org/Home/Download?ReferenceId=sUzbLVC3/aFB9wkj0dGAH042MuYo4AO0wFpvpNk+8IMFMG1xxi6x0w8ZvxucnWNR

    Looks to be a match

    What does the Installing Contractor say about why...
  15. https://www.ahridirectory.org/Home/Download?Refere...

    https://www.ahridirectory.org/Home/Download?ReferenceId=sUzbLVC3/aFB9wkj0dGAH5oFSHi8Xi07kUPHbjUe64EcjbLzq4k8W9qBYeU2+pGP

    The closet found that’s a AHRI match is for a 3 ton ID coil with a existing...
  16. Replies
    1
    Views
    115

    From install guide for the AUQ LIQUID LINE...

    From install guide for the AUQ

    LIQUID LINE SOLENOID VALVE — It is recommended that a bi-directional solenoid valve be placed in the main liquid line (see Figs. 13 & 15) between the outdoor unit...
  17. Replies
    5
    Views
    231

    “We have had two contractors come out and give us...

    “We have had two contractors come out and give us bids. I only vaguely understand the differences between the various options and am looking to educate myself so I can make a good decision.”

    Post...
  18. Replies
    11
    Views
    225

    Believe you can burn the blower motor out, as the...

    Believe you can burn the blower motor out, as the motor amperage draw can be higher than the rated amperage draw of the motor.
  19. Replies
    5
    Views
    169

    PM= Preventive Maintenance check Soooo, your...

    PM= Preventive Maintenance check

    Soooo, your return is 74? gives you 12 degree differential if so.

    If your insulated vapor line on the lineset at the OD or ID unit is not cool/cold and sweaty,...
  20. Replies
    5
    Views
    169

    Check at a supply vent close as possible to the...

    Check at a supply vent close as possible to the fan section, then compare to your return temperature. Somewhere around 20 degree split is pretty good.

    When was the last time you had a PM check?
  21. Replies
    11
    Views
    225

    Depending on configuration, suppose you can have...

    Depending on configuration, suppose you can have the possibility of icing up the coil, undue stress on blower motor, changing the amperage draw. Depending on AH location, ( hot attic as an example )...
  22. Replies
    5
    Views
    187

    “ 3 cubic air conditioner.” You probably mean...

    “ 3 cubic air conditioner.”

    You probably mean 3 ton 14 SEER system.

    Ask them for something like this to prove a matching system when they bid, and to prove your getting at least the 14 SEER on...
  23. Replies
    24
    Views
    659

    I would not necessarily rely on them to register...

    I would not necessarily rely on them to register your system. It can easily fall through the cracks. After itís installed, give it a few days or so then check yourself. Needing the serial number of...
  24. Replies
    24
    Views
    659

    I know some here give the matching numbers after...

    I know some here give the matching numbers after install, but IMO, getting it up front you can see what the SEER and EER and total cooling BTU are. ( on paper, not necessarily real world situation )...
  25. Replies
    24
    Views
    659

    You should be getting a rebate for the Daiken 16...

    You should be getting a rebate for the Daiken 16 SEER ( providing it’s a match ) and has the proper AHRI number as typically 16 SEER and a certain minimal EER gives you the minimum threshold for one,...
  26. Did not know the proper way to charge 410A -...

    Did not know the proper way to charge 410A - thanks

    The install guide that comes with each piece of equipment will state what the manufacturers specifications are. Of course that’s with a matched...
  27. Replies
    24
    Views
    659

    No sorry...it was not me who posted the site...

    No sorry...it was not me who posted the site about the parts and labor warranty...
  28. Replies
    24
    Views
    659

    The 6 or 12 year extended labor warranty ( the...

    The 6 or 12 year extended labor warranty ( the best in the industry ) should be stated in the contract and is offered by the bidding contractor, either backed by Daiken Asure program or offered by...
  29. Replies
    24
    Views
    659

    If those models where apples to apples comparison...

    If those models where apples to apples comparison ( which they where not a bare bone Carrier OD unit with a lesser SEER. ) Easily would have still recommended the Daiken just for the extended labor...
  30. Whoever is home to let them do the work ( sub...

    Whoever is home to let them do the work ( sub Contractor to the HWC ) If they plan on keeping the R22 refrigerant in your system ( saving what’s left then topping off as best they can to figure out a...
  31. Replies
    3
    Views
    207

    If your finished ceiling ( looking up at it from...

    If your finished ceiling ( looking up at it from a bedroom as an example ) the boot should be flushed with the drywall. If we are not on the same page in descriptions may want to post pictures....
  32. What’s left of the refrigerant can be pumped into...

    What’s left of the refrigerant can be pumped into the operational OD unit if they plan on keeping current refrigerant and topping off with R22. The filter drier should be replaced ( if located on the...
  33. Replies
    3
    Views
    207

    Don’t believe it’s code to put a return in a...

    Don’t believe it’s code to put a return in a bath..nothing wrong with a central return, I suppose individual returns is even better. I don’t see a problem with the metal boot slightly past the uneven...
  34. From Amana/Goodman install guide: EXPANSION...

    From Amana/Goodman install guide:

    EXPANSION VALVE SYSTEM
    NOTE: Units matched with indoor coils equipped with nonadjustable TXV should be charged by subcooling only.
    Run the remote on low stage...
  35. What type of metering device do you have, a...

    What type of metering device do you have, a piston or TXV, to get the 16 SEER you would need TXV. If they installed a Air Handler with a F in the beginning ( such as ARUF or ARPF ) those come from...
  36. Replies
    15
    Views
    398

    What’s your temperature split between a supply...

    What’s your temperature split between a supply register closest to the fan section and the return. Around 20 degree split ( give or take ) is what your looking for... you got many good...
  37. 20 degree higher than manufacturer spec. Across...

    20 degree higher than manufacturer spec. Across HX is better than 20 below, less stress on HX
  38. Do a load calculation to see what you really...

    Do a load calculation to see what you really need. If yours is oversized sell it.

    Any home improvement to your residence over the years with insulation, windows etc. as you seem to replace same...
  39. Replies
    15
    Views
    872

    https://hvac-talk.com/vbb/showthread.php?1838651-f...

    https://hvac-talk.com/vbb/showthread.php?1838651-filter-drier-in-the-discharge-line
  40. Replies
    15
    Views
    872

    No a solid core drier, we had a thread on this...

    No a solid core drier, we had a thread on this somewhat recently about driers in discharge lines from the factory. The AS HP we installed we specifically removed the top cover as there was writing on...
  41. Replies
    15
    Views
    872

    Seen manufacturers put the drier on the discharge...

    Seen manufacturers put the drier on the discharge line, the last American Standard Heat Pump we installed had one between the RV and compressor.
  42. Replies
    9
    Views
    432

    http://www.aireclima.com/carrier/pdf/58MCB-4PD.pdf...

    http://www.aireclima.com/carrier/pdf/58MCB-4PD.pdf

    Says it’s a multi speed blower, depending on size it’s either a 3 or 4 speed. Dated 2009

    Page one and thirteen

    If it’s set at low speed...
  43. Replies
    9
    Views
    255

    Iíd probably get couple Contractors to look and...

    Iíd probably get couple Contractors to look and see what they say, should cost nothing to look ( price is added into the bid ) and see if they are on the same page with recommendations and duct...
  44. Replies
    9
    Views
    255

    Why would you not ask the installing contractor...

    Why would you not ask the installing contractor what size duct they would run and if itís round metal or flex as even thou both are the same size the flex moves less CFM . Then ask another to do the...
  45. Replies
    9
    Views
    255

    Just at face value with the sun effect, it canít...

    Just at face value with the sun effect, it canít keep up with the load, I guess how does it work on cloudy or rainy days or does it maintain temperature prior to the sun hitting that room
  46. Replies
    9
    Views
    255

    You say ď room ď what doesnít get below 76 that...

    You say ď room ď what doesnít get below 76 that zone or pretty much the whole residence with all zones operating.

    What happens if this zone only calls for cooling does it cool down?

    Is this a...
  47. Replies
    24
    Views
    659

    “The Daikin guy made mention that after the...

    “The Daikin guy made mention that after the install another tech would come out and check all the pressures etc before registering product for warranty. I had assumed that was just ac lines etc, but...
  48. Lineset should be OK, probably better than some...

    Lineset should be OK, probably better than some of the Chinese made copper line sets nowadays, need to change metering device if TXV to new refrigerant. May get by OK with existing piston, or match...
  49. Replies
    24
    Views
    659

    “I don't know much about Daikin” Daiken is the...

    “I don't know much about Daikin”

    Daiken is the largest producer of HVAC equipment in the world..I believe

    If your getting a 12 year labor warranty find out who’s offering it, chances it’s...
  50. Changing just the OD unit or both the ID and OD...

    Changing just the OD unit or both the ID and OD unit?

    If both systems, new equipment comes charged from the factory for up to a certain amount of correctly sized lineset.

    Your friend A/C has...