Search:

Type: Posts; User: Chuck Brush

Search: Search took 0.02 seconds.

  1. The really nice and knowledgeable folks at...

    The really nice and knowledgeable folks at Ritchie Tech Help told me the clearance is supposed to be .001 inch if someone searches this topic looking for the same info. I needed. Also, the vanes go...
  2. Replies
    1
    Views
    5,432

    I finally contacted the Yellow Jacket tech help...

    I finally contacted the Yellow Jacket tech help and they were remarkably helpful. This sort of customer service is virtually nonexistent any more. The rotor to stater clearance on this pump is .001...
  3. Replies
    1
    Views
    5,432

    Replacing Vanes in 93100 vacuum pump

    Long story short, i need to reassemble my pump and neglected to measure the rotor clearance before I disassembled it. Does anyone know what that clearance should typically be? Or, does it matter?
    ...
  4. Yellow Jacket Vacuum pump internal clearances

    I have an older 93100 3CFM 2 stage pump that has never worked very well and I finally took it apart, mostly out of curiosity. I found the vanes in the second stage had been installed backwards,...