  1. Replies
    5
    Views
    149

    How big are these chest freezers? They require a...

    How big are these chest freezers? They require a 3/4'' ball valve?
  2. Replies
    22
    Views
    523

    lol,PHM, I don't know. And I agree.But,I read it.

    lol,PHM, I don't know. And I agree.But,I read it.
  3. Replies
    22
    Views
    523

    Not according to Copeland. Part Wind saves...

    Not according to Copeland. Part Wind saves starting amps, 50% on some set ups vs Across the Line.
  4. Replies
    22
    Views
    523

    As Per Copeland. An unloaded PWS comp will...

    As Per Copeland. An unloaded PWS comp will usually start to rotate on 1st contactor and then the 2nd winding kicks. But a loaded comp usually will not start to rotate w/ just the 1st contactor.
  5. Replies
    22
    Views
    523

    Copeland has a 23 pg Technical Information...

    Copeland has a 23 pg Technical Information article ,"Starting Methods and Unloaded Start For Semi-Hermetic Compressors" that mentions a Time Delay of 1 sec. (+-0.1 sec) in the Part Winding Start...
  6. I've had my Imperial Little Imp Tubing Cutter,2...

    I've had my Imperial Little Imp Tubing Cutter,2 size Imperial Flare Blocks and an Imperial Flare Yoke ever since 1970 or so.
  7. Replies
    16
    Views
    510

    But! Gimme a brake! I make my living from other...

    But! Gimme a brake! I make my living from other peoples screw ups. I rely on dopes,hacks!!! And I see my future growing,rapidly!
  8. Replies
    15
    Views
    26,366

    NO! I do now!! LOL,Tks

    NO! I do now!! LOL,Tks
  9. Replies
    15
    Views
    26,366

    Does that mean ALL other metering devices need...

    Does that mean ALL other metering devices need not worry about SubCooling?
  10. Replies
    12
    Views
    478

    I think that job would be a very interesting...

    I think that job would be a very interesting challenge,only if the $ is there.
  11. Replies
    22
    Views
    523

    What is the amps on each contactor? I thought...

    What is the amps on each contactor? I thought that a part wind start comp is supposed to act just like you described,minus a weird sound. There is a normal distinctive sound when this comp starts.
    ...
  12. Replies
    9
    Views
    297

    I had fun,for sure. I would leave RIGHT NOW if...

    I had fun,for sure. I would leave RIGHT NOW if they needed me......I learned a lot,I saw a lot,I did a lot,I experienced a lot, I matured a lot.And again,I HAD FUN doing it........ So, I thank You(s)...
  13. Too much air flow cfm/velocity?

    Too much air flow cfm/velocity?
  14. Replies
    9
    Views
    297

    X2,,,,, US Navy,Submarine Service,1968-1972

    X2,,,,, US Navy,Submarine Service,1968-1972
  15. Replies
    12
    Views
    414

    I enjoy being in my own Business.I enjoy being in...

    I enjoy being in my own Business.I enjoy being in the HVACR Profession. I enjoy going to Schools/Classes/Seminars to learn this HVACR stuff.I enjoy "practicing my Profession". I enjoy TOUGH JOBS. I...
  16. Replies
    25
    Views
    708

    I guess I'm thinking of icer's where the comp...

    I guess I'm thinking of icer's where the comp does not shut off between harvest and (re) freeze. Mani's are that way,I think.
  17. Replies
    12
    Views
    414

    Why are you going into your own business? That...

    Why are you going into your own business? That tells a lot,right there! You tell me yours, and I'll tell you mine.

    I agree w/ timebuilder and his thinking.
  18. Replies
    25
    Views
    708

    PTCR can be used on ice machines (MOSTLY) because...

    PTCR can be used on ice machines (MOSTLY) because most ice machines start in the "equalized(Hi/LO)pressure" mode. So there is no compressor differential pressure to overcome. If there is a press...
  19. Replies
    12
    Views
    364

    What way did VVT go? I went to several...

    What way did VVT go?

    I went to several Carrier VVT classes a few years back.
  20. Replies
    12
    Views
    364

    Does this include VRV? LOL.

    Does this include VRV? LOL.
  21. Replies
    16
    Views
    519

    When necessary, I put the drum inside of the bldg...

    When necessary, I put the drum inside of the bldg or inside a warm water bath or in the cab of the truck while blasting the heat.
  22. Replies
    15
    Views
    1,238

    I agree w/ that.

    I agree w/ that.
  23. Replies
    16
    Views
    407

    Well if you have "other"locations w/o any...

    Well if you have "other"locations w/o any problems then why not just copy your successfulness.?
  24. Replies
    14
    Views
    770

    Well at my last Copeland COSS thing, we were...

    Well at my last Copeland COSS thing, we were notified that a 50% poe/50% mineral oil is now "OK". A set of hoses for each oil? Mineral,Alke-Benzene,POE,PVE.?
  25. Replies
    14
    Views
    770

    What sources? I remember the original rule of 95%...

    What sources? I remember the original rule of 95% poe vs 5% mineral.

    A seperate set of gauges for burnouts?? Please explain? I use F/D in line on burnouts.
  26. Replies
    24
    Views
    1,050

    Call the Mfr of the structure. You might have to...

    Call the Mfr of the structure. You might have to build shelves/structure and support the heater off of that.Be careful of air stratification,trapping the heat "up there".

    Maybe a boiler and...
  27. How about that Old Retired SeeBee-"NavyGuy"...

    How about that Old Retired SeeBee-"NavyGuy" H-Talk Brother. Did you do anything like this dome during your deployments?????
  28. What is the Mfrg Pressure Spec for the dome???...

    What is the Mfrg Pressure Spec for the dome??? That photo of the dome does not seem to be "under deflated" due to not enough CFM/pressure.
    Was that access panel open when you took your readings? ...
  29. Replies
    13
    Views
    981

    Where is the LPC connected into the system? Where...

    Where is the LPC connected into the system? Where is your low side hose connected to?

    The overload is a dual sensing device, it is responsive to amperage and it is also responsive to the comp body...
  30. How many Service/Repair Techs did they have way...

    How many Service/Repair Techs did they have way back then?
  31. I have it on good faith. A long time ago the...

    I have it on good faith. A long time ago the Egypt's (rich ones) had "workers" drag huge rock blocks out into the desert in the evenings to get cooled by the deserts cold temps, overnite, then those...
  32. Replies
    52
    Views
    1,758

    I vote for clean evap,clean squirrel cage,then...

    I vote for clean evap,clean squirrel cage,then restart and rethink.
  33. Replies
    22
    Views
    1,075

    Bless ya Bro!

    Bless ya Bro!
  34. Replies
    52
    Views
    1,758

    What is desired indoor temp? 59psi/ r22 is not...

    What is desired indoor temp? 59psi/ r22 is not freezing.What SEER?
  35. Replies
    22
    Views
    1,075

    That must be some valuable Reach-In! We flew...

    That must be some valuable Reach-In!

    We flew into Orlando around 10am on a Tuesday,drove to Melbourne,I remember having fun,left Melbourne 4:45am drove back to Orlando this past Tuesday.What...
  36. Replies
    8
    Views
    888

    Is the comp overload internal to the comp body?...

    Is the comp overload internal to the comp body? Going S-R does not go thru the overload.
  37. Replies
    15
    Views
    768

    I gotta give this here info some thought. 6...

    I gotta give this here info some thought. 6 months hey?!

    I'll be back cause i'm headed to a Margaritaville/Yukon Jack 5 day Moment. I'm outta here for a little bit. 6 months huh? BEER TENDER...
  38. Replies
    11
    Views
    476

    A simple "load Calc" will tell how many BTU's are...

    A simple "load Calc" will tell how many BTU's are needed. A proper "load calc" will also take into consideration the required box RH% due to the product that is in the box. A AC/R system does not get...
  39. What is the recommended RLA and what was the...

    What is the recommended RLA and what was the "over RLA" reading?
    What did your boss/service manager have to say?
  40. Replies
    3
    Views
    346

    I need a good laugh( as you said), so please let...

    I need a good laugh( as you said), so please let us know what you did and how many of their mistakes you straighten out?
    By you being a "not a Pro" I kinda think you do qualify for a title as a...
  41. RSES has lots to read. RSES has lots of knowledge...

    RSES has lots to read. RSES has lots of knowledge to share. RSES is my favorite "go to 1st" for learning. RSES is famous for their SAM's. RSES is well known for their Monthly RSES Journal magazine....
  42. Replies
    28
    Views
    1,616

    WOW Dude,thats cool! Need an enthusiastic helper?

    WOW Dude,thats cool! Need an enthusiastic helper?
  43. Replies
    4
    Views
    508

    Business:Law,Practices,Operation is a whole...

    Business:Law,Practices,Operation is a whole different side of the HVACR Trade.A good Lawyer,Accountant, Insurance Agent,Banker, is required so my advice is only a could be/might be situation.

    Some...
  44. Next group of books as I was running out of...

    Next group of books as I was running out of time.

    Electricity.
    Alternating-Current Circuits, by J.M. Bryant & J.A. Correll, CR 1925, 492 pgs.
    Basic Electrical Principles, by Maurice Grayle...
  45. Books & Books & Books = Knowledge Knowledge & Knowledge

    This is in response to a couple of Guys asking for "it". I hope this helps. This is a partial list of my Library.
    CR means Copyright

    Steam-by Babcox & Wilcox,CR 1891,160 pgs.
    ...
  46. Replies
    13
    Views
    1,205

    Hi Jim, I'll post some old book titles later as...

    Hi Jim, I'll post some old book titles later as I'm out the door to go to work at 0600.
  47. Replies
    3
    Views
    364

    Sounds pretty good to me.

    Sounds pretty good to me.
  48. Replies
    4
    Views
    508

    How about a brief history of your where you are...

    How about a brief history of your where you are on the HVACR tree of knowledge as of now. KindaSorta ,why are you interested in the Business sector? I have a book or two that might help in both areas...
  49. Replies
    13
    Views
    1,205

    I am going to claim "asleep at the wheel"...

    I am going to claim "asleep at the wheel" here,lol,Gents.
    Jim1959, can you let me know what the subject was,concerning that list of books? I have lots & lots of books on lots & lots of HVACR...
  50. Replies
    46
    Views
    2,803

    In 40 years in my own business I have had 5...

    In 40 years in my own business I have had 5 vehicles.
    1- An old rusted Cadillac Coupe-de-Ville. Loaned to me by my Dad. It seemed to burn more oil then gas. My Buddies called it a "Polish Porche" as...