Search:

Type: Posts; User: TechmanTerry

Page 1 of 20 1 2 3 4

Search: Search took 0.26 seconds.

  1. Replies
    10
    Views
    225

    X2

    X2
  2. Replies
    10
    Views
    225

    What do you think is wrong? What i room temp?

    What do you think is wrong? What i room temp?
  3. Thread: Hoshizaki

    by TechmanTerry
    Replies
    8
    Views
    146

    What water drain pipe?

    What water drain pipe?
  4. Replies
    10
    Views
    275

    Both hinges and that door closer? That would be...

    Both hinges and that door closer? That would be nice, and proper
  5. Replies
    25
    Views
    547

    OP, look up the Heatcraft Technical Guide for a M...

    OP, look up the Heatcraft Technical Guide for a M Cond Unit . It has the nomenclature breakdown in it.
  6. Replies
    25
    Views
    547

    I have Cope Spec Sheet dated 1969 showing R -502...

    I have Cope Spec Sheet dated 1969 showing R -502 for medium temp applications. I sold a bunch in the early 80's when I went into Business.
  7. What fan speed will be used? Usually an oil...

    What fan speed will be used? Usually an oil furnace comes up short on CFM for AC. Back in the day a diff drive pully was swapped out for heat vs AC CFM w/ a 1 speed blower.
  8. My customers are right 100% of the...

    My customers are right 100% of the time!!!!!!!!!!! Thats because they "allow me" to do as I see fit ,100% of the time. I train my customers, it works for me. I 100% guarantee that I will...
  9. Right on! Right on!

    Right on! Right on!
  10. Replies
    2
    Views
    197

    Measurements of case? Storage on bottom of case?...

    Measurements of case? Storage on bottom of case? Gravity coils on ceiling of case? Comp MN# ? Refrigerant?
  11. Where did you connect R,Y,G? Sounds like someone...

    Where did you connect R,Y,G? Sounds like someone mis-wired the t'stat or could be one of the workers damaged the t'stat wire, ohm it out. The cooling was fine for two hrs, then you rewired t'stat and...
  12. Replies
    93
    Views
    2,201

    4-5-7 seconds. The meter needle would go at a...

    4-5-7 seconds. The meter needle would go at a nice steady pace as the meter battery would charge the cap. But be sure to discharge the capacitors "plate" before reversing the meter test leads to test...
  13. Put a SG at the evap and see if more freon is...

    Put a SG at the evap and see if more freon is needed. That head is way to low for a 90*F ambient
  14. You still your honor and integrity intact so that...

    You still your honor and integrity intact so that 1 hr is an investment.
  15. Replies
    93
    Views
    2,201

    I stock every single run oval single...

    I stock every single run oval single 2,3,4,5,6,7,7.5,10,12.5,15, 17.5,20,25,30,35,40,45,50,55,60,70,80,440vac. Then I have every oval dual run , then every single round run & every round run dual. I...
  16. Replies
    39
    Views
    1,193

    There are 3 diff ells. What I call a Plumbers Ell...

    There are 3 diff ells. What I call a Plumbers Ell has a SHARP 90* inside corner, no sweep at all. I'll post a photo later.
  17. Replies
    39
    Views
    1,193

    Hot Diggity Damn, another bending Pro! What's the...

    Hot Diggity Damn, another bending Pro! What's the name of that song "Dueling Benders!!!!!!!!" or was it Banjos? Nice looking.
  18. Replies
    93
    Views
    2,201

    I'll take a gander at those photos.

    I'll take a gander at those photos.
  19. Replies
    39
    Views
    1,193

    I use Long Radius ells 95% of the time and Short...

    I use Long Radius ells 95% of the time and Short Radius ells 4% of the time and a Plumbers Ell 1% of the time.
  20. Replies
    4
    Views
    343

    And we can squeeze in Manual Zr.

    And we can squeeze in Manual Zr.
  21. Replies
    8
    Views
    481

    Flapping Jaws here. If a proper sized supply is...

    Flapping Jaws here. If a proper sized supply is supposed to be 10 x 10( 100 sq in), then the return should be around a minimum of 20 % larger., 120 sq in. And no way in hell am I saying that a 10 x...
  22. Replies
    12
    Views
    436

    KindaSorta, There is some "wiggle room" in how...

    KindaSorta, There is some "wiggle room" in how much of the evap is filled w/ the atomized spray/mist of refrigerant. Flapping jaws here, a capillary tube will fill up 80% of the evap, a...
  23. General info is one thing. Specific info is...

    General info is one thing. Specific info is another. What is the Make, Model # of the unit that you are working on?
  24. Replies
    30
    Views
    918

    Freezing up means, frost? ice? Is the suction...

    Freezing up means, frost? ice? Is the suction line also frozen? The comp ?
  25. Replies
    40
    Views
    1,062

    Yes I have, but no way do I remember #'s. If...

    Yes I have, but no way do I remember #'s.

    If the press diff across the piston is typically hi ,like on a restart ,w/ a TXV, then the starting comp has a LOT of work to do to overcome that hi...
  26. On the grounding bus terminal bar, how close to...

    On the grounding bus terminal bar, how close to each other are the two ground wires. From the AC CU and the GFCI.
  27. Replies
    40
    Views
    1,062

    Today I worked on an old Scotsman CM506 and it...

    Today I worked on an old Scotsman CM506 and it has the ceramic soft start devise. There is no need for a "hard start" w/the pressure's being equalized. Back around 72' or so, many Carriers that had a...
  28. LOLALOT. Was that me?? Sounded like me, Talked...

    LOLALOT. Was that me?? Sounded like me, Talked like me. Smacked the hose down like me. Swore like me. LOL

    Can you put a pry bare under that suction line and give it a little upward goosh,just...
  29. Is belt driven Cope comp a normal thing in...

    Is belt driven Cope comp a normal thing in Australia? I just checked w/ my local United Ref and they are not aware of such an animal.
  30. Not sure what COMEF is. Copelaweld,...

    Not sure what COMEF is.

    Copelaweld, Copelametics,Scrolls,all Cope comps.
  31. As per pecmsg AND Copeland!!! From the...

    As per pecmsg AND Copeland!!! From the compressors view point "That" is ideal. Now theoretically having a 1*F SH would be cool, but, unobtainable. EEV are slightly better than regular TXV at...
  32. Replies
    40
    Views
    1,062

    They work just as everyone said, there is no...

    They work just as everyone said, there is no "re-starting" as in using a Pot Relay. I believe that Manitowoc uses them for starting a comp under "pressure equalized" conditions.
  33. Replies
    17
    Views
    717

    If I'm thinking correctly, R502 was "convertable"...

    If I'm thinking correctly, R502 was "convertable" to med temp around 1980ish +-.
  34. Replies
    9
    Views
    216

    Is there a condensate drain trap on the unit?

    Is there a condensate drain trap on the unit?
  35. How far apart are the cond units?

    How far apart are the cond units?
  36. Replies
    30
    Views
    783

    No way in hell!!!! All you need is a set of...

    No way in hell!!!! All you need is a set of gauges and a toolbox. Oh yea,and YOU!! Everything else can be purchased as needed. I started that way. I had to ask my Dad for money to purchase my very...
  37. Thread: RSES/B.A.

    by TechmanTerry
    Replies
    2
    Views
    236

    RSES,call them again.

    RSES,call them again.
  38. Replies
    2
    Views
    392

    Got the manual? Some of the micron gauges only...

    Got the manual? Some of the micron gauges only display a reading when the vac is down to the last 1" or so.
  39. Replies
    30
    Views
    783

    "Failure is not a option", so change that way of...

    "Failure is not a option", so change that way of thinking, young man.
  40. Replies
    30
    Views
    783

    Out of 10 service calls that require a road trip...

    Out of 10 service calls that require a road trip to the supply house, typically, how many Res customers are charged for that "driving labor/time"?
  41. Replies
    30
    Views
    783

    Be careful on how much you spend on parts before...

    Be careful on how much you spend on parts before actually being in business. Getting parts while being in business is a business expense. Getting parts now ,the $ is not a "wright off".
  42. Replies
    8
    Views
    736

    "I WANT" is one thing ,for someone to say to me,...

    "I WANT" is one thing ,for someone to say to me, I in-turn say to someone else,(Carrier,RSES,ACCA,Copeland). Does what "they" want screw up any of "You Guy's rules"?.. ASHRAE? ,DuPont? ,what say you?...
  43. For doing Res Ducts and getting by is one thing,...

    For doing Res Ducts and getting by is one thing, Knowing what you are doing is a whole other matter. Join ACCA and get access to ALL of their Manuals, (almost) A-Zr. Join RSES and get access to their...
  44. Is there a SGMI on this system?

    Is there a SGMI on this system?
  45. OP, got a Q for you. "A pints a pound, the world...

    OP, got a Q for you. "A pints a pound, the world around" How long will it take (w/ your setup) to evaporate 2 pints of water thats in the Accumulator?

    As a reference view point. The expansion...
  46. Replies
    20
    Views
    878

    Put a SG in at the evap and check for a full...

    Put a SG in at the evap and check for a full glass.
  47. Replies
    18
    Views
    712

    Could you take the night classes and squeeze in a...

    Could you take the night classes and squeeze in a few day classes for the extra stuff that they teach during the day?
  48. Replies
    20
    Views
    878

    64* F return air ? Sounds like a short circuiting...

    64* F return air ? Sounds like a short circuiting supply air problem.
  49. Replies
    45
    Views
    1,336

    I PREDICT, that I see a Hurricane Season...

    I PREDICT, that I see a Hurricane Season approaching.
  50. Years ago(83'-ish) I had a Duck Farm for a...

    Years ago(83'-ish) I had a Duck Farm for a customer. Their Blast Freeze water cooled condenser ruptured and flooded the freon system w/ water. This was a cascade system. The evap coil was approx 8'h...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4