Search:

Type: Posts; User: stanbyyourword

Page 1 of 20 1 2 3 4

Search: Search took 0.40 seconds.

  1. Replies
    192
    Views
    17,965

    so this would be far better and easier than ...

    so this would be far better and easier than chipkin modbus or modscan etc? maybe email me I dont want to hijack the thread :)
  2. Replies
    192
    Views
    17,965

    I wonder if this couldnt be used as a low ...

    I wonder if this couldnt be used as a low cost modbus testing device using a Bacnet utility such as BDT? anyone done any mapping yet?
  3. Replies
    15
    Views
    469

    mechanically identical , different controllers...

    mechanically identical , different controllers outside north america on this generation.
  4. Replies
    10
    Views
    562

    Hi gents Ive actually been wanting to ask this ...

    Hi gents Ive actually been wanting to ask this for awhile , this seems like a good time, I use Visio. My question is do any of you edit existing drawings on projects , so to scan then...
  5. Replies
    19
    Views
    667

    Neptronic are big players in Bacnet community,...

    Neptronic are big players in Bacnet community, and products are pure rock solid , know nothing about the humidifiers though! :)
  6. Replies
    10
    Views
    783

    very true , classic fouled tubes and barrel

    very true , classic fouled tubes and barrel
  7. Replies
    10
    Views
    783

    test flow switch thoroughly , take pressure drop...

    test flow switch thoroughly , take pressure drop readings across chiller barrell , compare to IOM
  8. Replies
    19
    Views
    667

    I use many neptronic products but never...

    I use many neptronic products but never anything with their humidifiers I do know this is a big market for them , and also all my experience with their Bacnet is rock solid from their HVAC...
  9. Replies
    192
    Views
    17,965

    Modbus = Enemy :)

    Modbus = Enemy :)
  10. whats the question? fairly simple compressors

    whats the question? fairly simple compressors
  11. Replies
    192
    Views
    17,965

    looking forward to hearing feedback on the new...

    looking forward to hearing feedback on the new gateway functionality
  12. Replies
    192
    Views
    17,965

    defo can you email me price?

    defo can you email me price?
  13. Replies
    5
    Views
    1,153

    vfd on voyager supply fans like intellipaks?

    vfd on voyager supply fans like intellipaks?
  14. Replies
    3
    Views
    486

    no chance? :) I guess what I would be looking...

    no chance? :) I guess what I would be looking for is a hand held pressure washer like these that take battery and power? exist?
  15. Replies
    3
    Views
    486

    cordless pressure washer

    anynone used these on chiller condensers with any success? ( obviosly not totally blocked ones) recommedation?
  16. Replies
    2
    Views
    452

    you can call them in italy support is decent

    you can call them in italy support is decent
  17. Replies
    46
    Views
    2,358

    I think their stuff rocks from little...

    I think their stuff rocks from little experience I have ,and was seriously looking into it as a second line , but in the end put that on the shelf ( I am also involved in Chillers) But have ...
  18. Replies
    12
    Views
    834

    thats why they come with guards, actually that...

    thats why they come with guards, actually that probably is an "option"
  19. Replies
    10
    Views
    526

    300ish

    300ish
  20. Replies
    10
    Views
    526

    https://cdn.hms-networks.com/docs/librariesprovide...

    https://cdn.hms-networks.com/docs/librariesprovider11/manuals-design-guides/datasheet/protocol-translators/datasheet-inbacmbmxxx0000.pdf?sfvrsn=72ff5fd7_10
  21. Replies
    10
    Views
    526

    intesis box all the way , sierra monitor ...

    intesis box all the way , sierra monitor are pwerful but definitely not for novice integrator


    https://www.intesis.com/contact/find-distributor
  22. Replies
    10
    Views
    526

    Intesis box

    Intesis box
  23. Replies
    59
    Views
    2,628

    ACCO still installs pneumatics on the...

    ACCO still installs pneumatics on the intellipak buildings. low rise etc right to this day :P
  24. Replies
    2
    Views
    519

    great course have personal contacts that toook...

    great course have personal contacts that toook it there online
  25. Replies
    4
    Views
    484

    .

    .
  26. Replies
    16
    Views
    1,718

    me too :)

    me too :)
  27. Replies
    27
    Views
    828

    I recommend Intesis for gateways top kit ...

    I recommend Intesis for gateways top kit support and documentation
  28. Replies
    27
    Views
    828

    Its simply a reference more mordern serial...

    Its simply a reference more mordern serial communications protocol
  29. Replies
    27
    Views
    828

    modbus only lives on in manufacturers that...

    modbus only lives on in manufacturers that refuse to invest in development and licensing of BACnet , I think it`s OK for reading values like meters
  30. Replies
    27
    Views
    828

    It has MSTP haha :)

    It has MSTP haha :)
  31. Replies
    55
    Views
    2,432

    Healey saves the day

    Healey saves the day
  32. Replies
    55
    Views
    2,432

    Im working on PH diagrams plotting kj/kg to...

    Im working on PH diagrams plotting kj/kg to calculate real time refrigeration output to be monitored at all times with changing conditions, now thats blowing my mind, not plotting the values on...
  33. Replies
    55
    Views
    2,432

    we could all try and be a bit nicer and more...

    we could all try and be a bit nicer and more supportive here , this should be something of a brotherhood. enough nastiness in the world
  34. Replies
    55
    Views
    2,432

    yes exactly flooded vessels SH SC negligible...

    yes exactly flooded vessels SH SC negligible at best!
  35. Replies
    12
    Views
    550

    Innotech Omni remote webserver allows a pretty...

    Innotech Omni remote webserver allows a pretty massive amount of adjustment to programming , short of adding and deleting blocks you are pretty much in full control of tuning tweaking and...
  36. Replies
    55
    Views
    2,432

    haha bit harsh for xmas time! wait til new year...

    haha bit harsh for xmas time! wait til new year ;)
  37. Replies
    2
    Views
    574

    Merry Xmas

    Happy Holidays to all the Cool guys and lets hope sanity returns to us in 2021! stan
  38. Replies
    55
    Views
    2,432

    approach temps? delta T discharge superheat ...

    approach temps? delta T discharge superheat are my guess. alot of yorks have actual evap sight glass
  39. Thread: R454a

    by stanbyyourword
    Replies
    8
    Views
    797

    448 seems to be the way to go for 404a retro ,

    448 seems to be the way to go for 404a retro ,
  40. Replies
    0
    Views
    554

    FIELDPIECE MR45 RECOVERY

    Hi guys mY appion G5twin valves failed friday and theres none in country to replace! so was forced to 1 borrow a promax or 2 buy a new machine because I need it monday , I will still get...
  41. Replies
    24
    Views
    1,490

    we should talk in pm or maybe a new post so not...

    we should talk in pm or maybe a new post so not to get off track with op
  42. Replies
    24
    Views
    1,490

    Hi Ice did you see the private message I sent you...

    Hi Ice did you see the private message I sent you last week?
  43. Replies
    73
    Views
    8,169

    that sometimes still needs proven in the field ...

    that sometimes still needs proven in the field ie bench test before spending too much time looking at ductwork , on a similar job recently
  44. Innotech America :)

    Innotech America :)
  45. yep totaly agree, its not what you know its who...

    yep totaly agree, its not what you know its who you know , but thta can run out eventualy, nedto provide the goods at some point. Ive been lucky starting in controls here on hvctalk s you know
  46. if you email me i will send it

    if you email me i will send it
  47. Replies
    29
    Views
    11,057

    From what I understand the components down to...

    From what I understand the components down to the tiles are selected specially to retain heat
  48. Hi Jay do you have the sequence of operation for...

    Hi Jay do you have the sequence of operation for the staging and control logic of the valves and outputs etc? With actual values of temperatures and pressures? That would be super good resource to...
  49. YVAA is the new RTAA?? haha hope youre well...

    YVAA is the new RTAA?? haha hope youre well :cheers:
  50. lots of posts about this on forum if you do...

    lots of posts about this on forum if you do search , will be clearer. yes It is on a subcooling value I an 90% sure.
Results 1 to 50 of 1000