  1. Replies
    16
    Views
    323

    Furnace install guide should have all the...

    Furnace install guide should have all the information you need in regards to temperature rise across HX and static. Even if they come out or came out or they pretended to find one ( never did a real...
  2. Replies
    14
    Views
    212

    What do you have, a new OD unit and used AH, both...

    What do you have, a new OD unit and used AH, both parts are used? and just has a holding charge? One part new, other part used, both parts new, as you mention customer supplied.

    How did you...
  3. Replies
    14
    Views
    212

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&so...

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=2&ved=2ahUKEwj05vKNpabnAhUJP60KHQzlDM0QFjABegQIAxAC&url=https%3A%2F%2Fwww.alpinehomeair.com%2Frelated%2FLow%2520Ambient%2520Kit%2520Instal...
  4. Replies
    16
    Views
    323

    So you going to ask for a commissioning report?...

    So you going to ask for a commissioning report? Seems like a good starting point. If not HX and or blower motor may have a early failure?
  5. Replies
    16
    Views
    323

    What did your old furnace have for a blower motor...

    What did your old furnace have for a blower motor the workhorse PSC or the whimpy ECM motor. Your suppose to take readings with blower panel in place. Make sure your only reading blower motor and not...
  6. Replies
    16
    Views
    323

    No mention if they did a startup/commissioning...

    No mention if they did a startup/commissioning report, things like temperature rise across HX, static pressure, gas pressure, blower speed, amprege readings of motor(s) among other things are all...
  7. In a perfect world, with perfect ductwork and...

    In a perfect world, with perfect ductwork and perfectly field charge refrigerant and who knows what else the CX35-36B gives you 34,200 BTU cooling. 12.20 EER, 14.25 SEER. AHRI number 8259233

    The...
  8. Replies
    16
    Views
    323

    I’m use to seeing return ducts ( if more than one...

    I’m use to seeing return ducts ( if more than one ) mounted on the return box sides that’s mounted to a single furnace and not on both sides of the furnace hooked directly to the furnace.
  9. Replies
    16
    Views
    323

    The blower wheel has curved blades, the curved...

    The blower wheel has curved blades, the curved part ( scoops up the air ) and should be scooping up the air and throwing it across the HX. You have a giant arrow on the blower housing to show...
  10. Replies
    16
    Views
    323

    What was your amprege drawing of the motor,...

    What was your amprege drawing of the motor, didn’t they check that? ( with blower door panel on ) why two returns one on each side with restrictive air filters. What was your static pressures? Didn’t...
  11. Replies
    16
    Views
    323

    Did they at least install the blower wheel (...

    Did they at least install the blower wheel ( correct OEM size ) in the correct rotation and not backwards :whistle:
  12. Where these photos taken just before the HVAC...

    Where these photos taken just before the HVAC Contractors finished up? as the furnace shut off switch is off. Reason for asking is that at least one of your manual balancing damper ( in top photo )...
  13. Equipment could be oversized for your duct, poor...

    Equipment could be oversized for your duct, poor duct design, static pressure probably never checked, blower fan not set correctly, may have been left at factory default setting. Ductwork ( metal )...
  14. Replies
    11
    Views
    286

    Yes, looks like it. That part solved...

    Yes, looks like it. That part solved...
  15. Replies
    11
    Views
    286

    Says it was built January 2019 ( OD unit ) ...

    Says it was built January 2019 ( OD unit ) Reading the blower section built date was 8th week of 2006

    You do not have a XP15, you have a EL15XP1 which is a current line.
    ...
  16. Replies
    11
    Views
    286

    The top site is dated 4/2008 ( bottom of last...

    The top site is dated 4/2008 ( bottom of last page ) the lower site is dated 2009
    ...
  17. Replies
    11
    Views
    286

    What’s you ID coil number, you have a mismatched...

    What’s you ID coil number, you have a mismatched system ( does not mean it won’t work ) as you have a UTC furnace. I could not open up your google site. But anyway maybe it’s a Canadian thing but...
  18. Replies
    11
    Views
    286

    I donít even see a XP15 Heat Pump listed on...

    I donít even see a XP15 Heat Pump listed on Lennox current site. XP14 and XP16. What the complete model number of OD and ID unit to see if itís at least a matching system.

    Possibly your final...
  19. Hopefully someone registered your Air Handler, (...

    Hopefully someone registered your Air Handler, ( as that part seems to be a keeper? ) as manufacturers warranty decreases significantly if never registered.

    Seems like your stuck on Inverter, if...
  20. AHRI number 9036787 for the Champion TH16B48 4...

    AHRI number 9036787 for the Champion TH16B48 4 ton with your existing Air Handler.

    Check yourself
    ...
  21. If your looking for a AHRI matching system, the...

    If your looking for a AHRI matching system, the TH16B36 is not a match for the Air Handler you have.

    Check yourself. Do not need to add the brand name. Works in Lower Case also, put in partial...
  22. Replies
    13
    Views
    346

    Get a Heat Pump thermostat that has a emergency...

    Get a Heat Pump thermostat that has a emergency heat setting, as I believe not all of them have that feature automatically.
  23. Replies
    3
    Views
    267

    And have them clean coil, looks like lint build...

    And have them clean coil, looks like lint build up on it....
  24. Replies
    10
    Views
    321

    I like to remove them from that location myself...

    I like to remove them from that location myself and install one in the lineset, figure if I never Service that unit again and they get another Company in the future and they send out a lesser...
  25. Replies
    10
    Views
    321

    Did you remove the factory drier? I’m sure the...

    Did you remove the factory drier? I’m sure the VSX has them.
  26. Get your serial number of your OD unit and ID...

    Get your serial number of your OD unit and ID unit and go to Lennox web-site to “ check warranty status “ to see what you get. If this is a new house and your the original owner possibly someone...
  27. Replies
    10
    Views
    321

    Did you figure out what your friends problem was...

    Did you figure out what your friends problem was from your last post, among other things the low ambient control? and the charging procedure thingy.
  28. Replies
    10
    Views
    321

    Dated 2013 for a Goodman GSX13 same unit...

    Dated 2013 for a Goodman GSX13 same unit basically, shows 7/8” OD for up to 24’ I would not be worried about it....

    Also talks about a inverted loop if Air Handler is mounted higher than OD unit....
  29. How was it working 2, 3, 4, 5 years ago compared...

    How was it working 2, 3, 4, 5 years ago compared to this year at similar OD and ID temperatures, in regards to run times?

    Is your system defrosting satisfactorily, and the whole coil clean after...
  30. How old is the system? Yes Heat Pumps and teens...

    How old is the system? Yes Heat Pumps and teens OD temperature runs for extremely long times, and loose BTU ratings.

    As an example only a expanded heating data from a competitor ( used this as it...
  31. Replies
    3
    Views
    184

    Purchase portable units or window rattler(s),...

    Purchase portable units or window rattler(s), donít think they are overly expensive. Depending on size of your residence, may need couple or so. Can always sell them when you save money for a new...
  32. Replies
    5
    Views
    490

    If that’s the only problem, the customer must be...

    If that’s the only problem, the customer must be happy. You probably have a friend for life.:whistle:
  33. Replies
    72
    Views
    1,714

    CCH are typically energized when...

    CCH are typically energized when compressor/system not running.

    BTW if you go new OD unit and the unit has a CCH, the install guide will usually say to energize OD unit for 24 hours prior to 1st...
  34. Replies
    72
    Views
    1,714

    Do you have a reciprocating or scroll compressor,...

    Do you have a reciprocating or scroll compressor, if recip. Possibly your crankcase heater is not working anymore ( if equipt. ) your oil may be washed out of the compressor more so than usual, if...
  35. Replies
    72
    Views
    1,714

    Hey,...not to shabby, the Goodman GSZC16024 ( two...

    Hey,...not to shabby, the Goodman GSZC16024 ( two stage and communicating ) is a AHRI match with your existing Air Handler. Enter this number 202149338 to view certificate, says 15 SEER, 12.5 EER,...
  36. If you flip your thermostat to emergency heat and...

    If you flip your thermostat to emergency heat and it works, ( even partially ) why would you have to need a complete new heater element. Heaters come in many different KW sizes, and options.

    May...
  37. Built 18th week of 2010. Packaged unit is a...

    Built 18th week of 2010. Packaged unit is a common term to what you have ( one piece ) You don’t mention how long it runs after resetting, ( the A/C )
  38. Replies
    72
    Views
    1,714

    “ Yes, they replaced the filter drier in the...

    “ Yes, they replaced the filter drier in the outside unit when they installed the new air handler last year.”

    What does the above statement mean, they removed the factory drier from the OD unit,...
  39. Replies
    11
    Views
    398

    So what do you have for heat? Electric heaters in...

    So what do you have for heat? Electric heaters in the Air Handler, if so is the heater element the same size ( KW size ) as your old system? that’s the part that’s tripping, the Air Handler correct?...
  40. Replies
    11
    Views
    398

    New electric could mean the outdoor “whip” the...

    New electric could mean the outdoor “whip” the flex electric housing and wiring from the new OD shutoff switch to the OD unit.

    If your system got registered, you shoooould have a 10 years parts...
  41. Replies
    72
    Views
    1,714

    Absolutely question them when they come back out...

    Absolutely question them when they come back out on a warmer day, preferably much warmer than the 60 degree minimum, get a good load on the indoor temperature also it says +- 1 degree of the number...
  42. Replies
    7
    Views
    301

    Hopefully someone registered your furnace for you...

    Hopefully someone registered your furnace for you as manufacturers warranty decreases significantly if never registered.
  43. The DSZC18 you mention is not a current model,...

    The DSZC18 you mention is not a current model, you mention you have a GSZC18, different animal. Those ratings are in a perfect world scenario, mentions those readings taken at 70 degree dry bulb...
  44. I’d be curious where you got those numbers, as...

    I’d be curious where you got those numbers, as the expanded heating data sheets mentions a MBVC1600/2000 ( modular blower ) and a upflow A coil of different sizes, not a horizontal coil with a...
  45. Replies
    20
    Views
    814

    Hopefully someone registered everything as...

    Hopefully someone registered everything as manufacturers warranty decreases significantly if never registered.
  46. Replies
    72
    Views
    1,714

    I was talking more about the defrost location as...

    I was talking more about the defrost location as this service bulletin mentions the GSZ1324/30 which is what you have. Granted it’s dated 2010 and probably does not apply to your year, you never...
  47. Replies
    20
    Views
    814

    Mentions GSZ16, affecteted models are the 1.5...

    Mentions GSZ16, affecteted models are the 1.5 ton, 2 ton, 2.5 ton and 3 ton, you don’t mention what size you have, not saying this is your case, as your refrigerant charge could be off. Starting...
  48. Replies
    72
    Views
    1,714

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&so...

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&ved=2ahUKEwjPiO3Nn47nAhWMbc0KHeZ2C8sQFjAAegQIBBAB&url=https%3A%2F%2Fmobile.goodmanmfg.com%2Fmobileapp%2Fstellent%2FToolkit%2FTechService...
  49. Replies
    72
    Views
    1,714

    Gave you the factory charge for a 1.5 ton OD unit...

    Gave you the factory charge for a 1.5 ton OD unit as you mentioned you had a 1.5 ton OD unit in post 13 . In post 17 says you have a 2 ton OD unit, which shows to have a factory charge of 99 ounces....
  50. Replies
    72
    Views
    1,714

    So when you completely defrosted the complete OD...

    So when you completely defrosted the complete OD coil 100% with hot water, inside and outside of the coil did you notice if the distributor tubes just after the OD metering device start frosting...