  1. Replies
    50
    Views
    808

    Seems like a good bit of DIY aid is being given...

    Seems like a good bit of DIY aid is being given out in this thread. Along with how to vids.

    Sorry, this is not a DIY site.

    Thread closed.
  2. Replies
    5
    Views
    270

    You have a parts only warranty. The installing...

    You have a parts only warranty. The installing contractor provides the labor warranty. And in this case, your the installing contractor.

    Sorry, we're not a DIY site.

    Thread closed.
  3. Replies
    38
    Views
    846

    Merged threads.

    Merged threads.
  4. Replies
    4
    Views
    202

    Sounds like you did. Sorry, this is not a DIY...

    Sounds like you did.

    Sorry, this is not a DIY site.

    Thread closed.
  5. Replies
    15
    Views
    647

    20' of 12" with 2-90s. When you include the...

    20' of 12" with 2-90s. When you include the transition to round at the plenum. Will most likely be close to 100' of TEL.
  6. Replies
    1
    Views
    116

    Then the one set to 40 will do all the work. ...

    Then the one set to 40 will do all the work.

    Set one 2 degrees lower than the other.
  7. Set back during the day while your at work. 1...

    Set back during the day while your at work. 1 degree for every hour your at work.

    Set back at night while in bed. 1 degree for every hour your asleep/or trying to sleep.
  8. Navien. A much better boiler then what you...

    Navien. A much better boiler then what you have/had. So is Rannai.
  9. Replies
    6
    Views
    268

    Moved to AOP. Neither prices nor links to...

    Moved to AOP.

    Neither prices nor links to direct purchase sites are permitted in the open forums.
  10. Bet the boiler water temp is set too low.

    Bet the boiler water temp is set too low.
  11. Replies
    16
    Views
    450

    Lots of heat pump compressors re changed out in...

    Lots of heat pump compressors re changed out in the winter. And you have to recharge the system.

    Then there are the commercial and industrial applications that use A/C 365.
  12. Replies
    3
    Views
    152

    Moved to AOP.

    Moved to AOP.
  13. Boiler probably isn't set up right. It should...

    Boiler probably isn't set up right. It should provide hot enough water that the air temp from the air handler doesn't get cold/cool when it gets colder outside.
  14. Replies
    29
    Views
    7,856

    And the thread was only started 5 year ago.

    And the thread was only started 5 year ago.
  15. Pic of boiler label not sharp enough to read...

    Pic of boiler label not sharp enough to read model number. How many BTUs is it. And what water temp is it set to reach? Is it using outdoor reset?
  16. Replies
    20
    Views
    607

    The temp drops a little, just the thermostat is...

    The temp drops a little, just the thermostat is programed not to show it. It keeps the temp with in 1 degree of set temp.
  17. Replies
    1
    Views
    212

    Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  18. Replies
    9
    Views
    416

    Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  19. Your welcome.

    Your welcome.
  20. Could easily have enough charge to operate when...

    Could easily have enough charge to operate when its in the 49s, but lock out on low pressure when its in the 30s. Could have sprung a leak later in the summer that didn't hurt performance enough for...
  21. Replies
    19
    Views
    664

    Much easier and quicker to use the original...

    Much easier and quicker to use the original plenums, then make up new ones and install them.
  22. Thread: Cad Ohms

    by beenthere
    Replies
    25
    Views
    641

    Fuel, air/oxygen, source of ignition. Thats all...

    Fuel, air/oxygen, source of ignition. Thats all that is required for combustion. But sometimes getting those three in the right quantity is a problem.

    Is the oil tank inside or outside?
  23. Could be low on charge, which would also explain...

    Could be low on charge, which would also explain why the aux heat is coming on when its 40 or warmer outside.
  24. A simplified example of 3 CPH. Would be on for 10...

    A simplified example of 3 CPH. Would be on for 10 minutes, off for 10 minutes, on for 10 minutes, off for 10 minutes, on for 10 minutes, off for 10 minutes. With the set temp having been reached each...
  25. Replies
    9
    Views
    229

    Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  26. No, but in the winter position it can. Might be...

    No, but in the winter position it can. Might be okay to set Stat to 55 then.
  27. Thread: Cad Ohms

    by beenthere
    Replies
    25
    Views
    641

    Make sure the cad cell is aligned properly.

    Make sure the cad cell is aligned properly.
  28. Replies
    19
    Views
    664

    It is more labor. Saying it isn't. Is like...

    It is more labor.

    Saying it isn't. Is like saying since the break pads of a car are being changed anyway, replacing the break rotors isn't anymore labor. But it is.

    We aren't allowed to discuss...
  29. How long does it stay off? Using a swing...

    How long does it stay off?

    Using a swing thermostat, it might lower the humidity better while its running. But being off so much longer, it might climb back just as high before the AC runs again....
  30. The cold return air temp causes the flue gasses...

    The cold return air temp causes the flue gasses to condense in the primary heat exchanger. Which causes corrosion in it. Doesn't matter if once a week the furnace is ran till the home temp is above...
  31. Replies
    1
    Views
    148

    No. Sorry, this is not a DIY site. Thread...

    No.

    Sorry, this is not a DIY site.

    Thread closed.
  32. Replies
    7
    Views
    254

    Moved to AOP. As above, depends on how it is...

    Moved to AOP.

    As above, depends on how it is installed.
  33. Replies
    1
    Views
    166

    Won't help that room much, if any. Unless you...

    Won't help that room much, if any. Unless you increase the register size. Which isn't any easier than making another hole in the floor.
  34. 5 CPH is too many, and the thermostat is doing as...

    5 CPH is too many, and the thermostat is doing as its set up to do. Reset the CPH to 3 or 2.
  35. Replies
    2
    Views
    216

    Depending how much infiltration your house has,...

    Depending how much infiltration your house has, both count.
  36. Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  37. Replies
    4
    Views
    259

    Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  38. Replies
    9
    Views
    397

    Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  39. Replies
    10
    Views
    427

    Moved to AOP.

    Moved to AOP.
  40. Replies
    14
    Views
    678

    Moved to AOP.

    Moved to AOP.
  41. Replies
    2
    Views
    260

    Sorry this is not a DIY site. Thread closed.

    Sorry this is not a DIY site.

    Thread closed.
  42. Replies
    5
    Views
    276

    Sorry this is not a DIY site.

    Sorry this is not a DIY site.
  43. Replies
    10
    Views
    449

    They will warranty a compressor that over heats,...

    They will warranty a compressor that over heats, or is only partially pumping the volume of refrigerant it is suppose to.
  44. Moved to AOP.

    Moved to AOP.
  45. Thread: Blower issue

    by beenthere
    Replies
    18
    Views
    887

    If the thermostat is set to fan “on”. Turn it to...

    If the thermostat is set to fan “on”. Turn it to auto.

    Sounds like it could also be an interrupted heat call.
  46. Thread: Blower issue

    by beenthere
    Replies
    18
    Views
    887

    Is it a single or two stage furnace?

    Is it a single or two stage furnace?
  47. Replies
    13
    Views
    532

    Doubt you really need the Observer, but myself I...

    Doubt you really need the Observer, but myself I would set it up to use the thermostat to control staging .
  48. Replies
    9
    Views
    316

    Still won’t have warm bedrooms for your daughters...

    Still won’t have warm bedrooms for your daughters since the upstairs won’t need heat when the basement does in spring and fall.

    Sort this is not a DIY site, our site rules prohibit us from giving...
  49. Replies
    19
    Views
    1,017

    The SH and SC values you posted sound like you...

    The SH and SC values you posted sound like you didn’t check them and are just giving a guesstimate range.

    Please take actual pressure and temp readings of the lines along with indoor and outdoor...
  50. Replies
    3
    Views
    323

    A little 500 to 750 watt electric baseboard...

    A little 500 to 750 watt electric baseboard should do fine for that area.

    Radiant floor is great, but might cost more upfront then it’s worth for a mud room/laundry room.