Search:

Type: Posts; User: thatguy

Page 1 of 8 1 2 3 4

Search: Search took 0.04 seconds; generated 16 minute(s) ago.

  1. Replies
    37
    Views
    846

    Me too. Only problem is that bbq stuff never...

    Me too. Only problem is that bbq stuff never makes my food cold it always has quite the opposite effect... flame broiled :D


    Sent from my iPhone using Tapatalk
  2. Thread: Rudd fan issue

    by thatguy
    Replies
    2
    Views
    91

    Could be a program issue on your tstat. Iíve come...

    Could be a program issue on your tstat. Iíve come across some that behave this way in certain instances.


    Sent from my iPhone using Tapatalk
  3. Replies
    10
    Views
    266

    Anyone else get this?

    I see... A building in heat can be a challenging beast to tame. It happens to all of them though so itís best to just prepare for it before it occurs. For now, itís probably best to just keep your...
  4. Replies
    37
    Views
    846

    Sometimes when I run out of cows milk for my...

    Sometimes when I run out of cows milk for my cereal I substitute with a little cats milk. Sure the odor is a little different, but the name sounds almost the same.... I see no reason why you couldnít...
  5. Replies
    7
    Views
    265

    I use a dual Fluke setup (322 clamp, 16 DMM). I...

    I use a dual Fluke setup (322 clamp, 16 DMM). I keep the amp clamp on my belt loop and a pocket of tools for most inspections that Iím familiar with. I bring out the bag that has the DMM and otter...
  6. Replies
    4
    Views
    274

    Forum rules specify we canít advise DIY...

    Forum rules specify we canít advise DIY instructions on how to fix your problem. We can say that it doesnít sound like its operating correctly and it sounds like it could benefit from having a...
  7. Replies
    26
    Views
    809

    Is it classified as storage water heating...

    Is it classified as storage water heating equipment when it doesnít store hot water? Such as a continuous water heating system?


    Sent from my iPhone using Tapatalk
  8. Replies
    26
    Views
    809

    You may have less of an issue with high pressure...

    You may have less of an issue with high pressure if you use plastic pipes. PEX for example may have enough flex in it to absorb a small amount of temperature fluctuations. This is just a guess though...
  9. Replies
    26
    Views
    809

    Thatís fine for the times when you use hot water,...

    Thatís fine for the times when you use hot water, but there are times when only cold water is used. Washing vegetables, watering the lawn, etc. That can create a large volume of cold water that will...
  10. Replies
    13
    Views
    462

    Forgive me for my looking up the numbers... ...

    Forgive me for my looking up the numbers...

    Have you checked the flame rod if that is what it is using for flame verification? May be on the cusp of needing replacement or cleaning?

    Also have...
  11. Replies
    26
    Views
    809

    Iíve seen a short 30í run of 1/2Ē copper line...

    Iíve seen a short 30í run of 1/2Ē copper line rise from 30psi to over 125psi as it warm to the rooms ambient temperature. I donít recall exactly what pressure it finally reached when I discovered the...
  12. Replies
    26
    Views
    809

    Unless your local codes say otherwise, Your house...

    Unless your local codes say otherwise, Your house only needs it if you have a check valve on your city supply line. This is most commonly fond in your water meter, or anywhere after a check valve on...
  13. I guess I wasnít very clear. In the product...

    I guess I wasnít very clear.

    In the product specs for the 87v Max that you posted, it has a comparison chart that lists the specs of the 87V and the 87v Max, side by side.

    The side by side...
  14. In the first link you posted it says the 87v will...

    In the first link you posted it says the 87v will withstand a 3 meter drop... I donít think it was designed for that.

    They also mentioned that it has every feature that he 87v has, except it only...
  15. Replies
    7
    Views
    254

    There are lots of different ways they can be...

    There are lots of different ways they can be installed. For instance, they can be incorporated into an existing ducted furnace so it uses the existing duct work, it can be a stand alone setup where...
  16. Fluke 87V-MAX vs 28II ??? (87V MAX... apparently it's a thing)

    It seems fluke has released an 87V MAX DMM but I can't figure out what the difference is between the 87V MAX and the 28II

    Has anyone noticed this meter before? it looks like it only came out...
  17. Replies
    18
    Views
    460

    Two infrared heaters for one room?

    I think itís the fire hazard associated with the plug in type devices that has caught the attention of the insurance agencies.

    Let them know what you want the HP to do so they are aware of its...
  18. Replies
    18
    Views
    460

    There are better more expensive options out...

    There are better more expensive options out there. If you use them then put them somewhere safe and plug them into two different dedicates circuits. For insurance reasons, in my location, many...
  19. Replies
    18
    Views
    460

    I second the redundancy suggestion. When a temp...

    I second the redundancy suggestion. When a temp must be maintained and to are not people on site to monitor, then you need a second, or in some cases third unit (double redundancy) depending on how...
  20. Replies
    37
    Views
    1,789

    low sub cooling with replaced condenser coil

    I suspect the OP was trying to determine if there was a problem with the system without using gauges. Possibly just came across it on a maintenance Iím guessing. This of course is all speculation but...
  21. Thread: What is it??

    by thatguy
    Replies
    17
    Views
    623

    Why do you have that much oil dripping out of...

    Why do you have that much oil dripping out of your liquid line?


    Sent from my iPhone using Tapatalk
  22. Thread: What is it??

    by thatguy
    Replies
    17
    Views
    623

    Please donít hi jack threads. Start a new thread ...

    Please donít hi jack threads. Start a new thread about your question in the AOP section and someone will be happy to help you out.


    Sent from my iPhone using Tapatalk
  23. The 87v ( and itís waterproof clone the 28II) do...

    The 87v ( and itís waterproof clone the 28II) do pretty much everything we need it to but It doesnít look like the 179 can do microamps according to their chart. The 116 (Flukes HVAC DMM) will do it....
  24. This is impossible, cant find a meter that works, sick of FP

    Ahhh, thank you for catching my misinformation. I had it in my head that they were both rated for 1000V. My apologies for the mistake.

    ... and I apparently didnít read the post well enough. I...
  25. Some of the meters donít have the resolution or...

    Some of the meters donít have the resolution or accuracy to be able to decide the results. You need to have the third decimal place if you are going to do that.


    Sent from my iPhone using...
  26. I believe the Fluke 902FC will do that. Iíve been...

    I believe the Fluke 902FC will do that. Iíve been lookin for something similar and for a clamp meter I have narrowed it down to either the 902FC or the Fluke 325.

    The 325 does everything plus...
  27. Have you completed the basic maintenance on the...

    Have you completed the basic maintenance on the system yet? Checked for plugged filters, dirty blower wheel, worn pulleys and belt? Made sure there are no volume dampers that have decided to close...
  28. Replies
    18
    Views
    1,249

    Maybe there is more to it then we see. Maybe itís...

    Maybe there is more to it then we see. Maybe itís to help contain the water dripping off of a frozen suction line? But by containing the liquid line in a block of ice it would increase subcooling...
  29. Replies
    46
    Views
    4,301

    Everybody is always quick to blame the installer...

    Everybody is always quick to blame the installer when the home owner is quite often the problem. They are the ones that shopped around and asked the questions, checked the references, and saw the...
  30. Replies
    18
    Views
    1,249

    ... But then the inspector wonít know what was...

    ... But then the inspector wonít know what was used and they wonít pass it.


    Sent from my iPhone using Tapatalk
  31. Replies
    18
    Views
    1,249

    Huh... so it did happen. Sent from my...

    Huh... so it did happen.


    Sent from my iPhone using Tapatalk
  32. Replies
    25
    Views
    846

    What I was trying to drive home with the...

    What I was trying to drive home with the reference to the size variation between the bulb and the motor is that the perceived difference in heat output is different because the heat is dispersed...
  33. Replies
    25
    Views
    846

    Looking at a bulb and a motor operating side by...

    Looking at a bulb and a motor operating side by side isnít really a fair comparison. The bulb has a rather small filament surface area where all of the work is being performed and that is contained...
  34. Replies
    4
    Views
    386

    Mission Impossible

    Whenever Iíve installed ductwork in a prison they have all had burglar bars welded in place. Even low security has that. Iím impressed that he got through that without getting caught.

    Itís not a...
  35. Replies
    4
    Views
    364

    Iím unfamiliar with this unit. What make are...

    Iím unfamiliar with this unit. What make are they? Are they a package unit or a split unit?

    What location are you in?

    What are the air temperatures? What have you tried doing to troubleshoot...
  36. Replies
    37
    Views
    1,789

    Iím curious if youíve been back to look at this...

    Iím curious if youíve been back to look at this unit some more.

    Also, Iím still a little confused by these numbers you posted here. If Iím understanding correctly then you are saying you have...
  37. Replies
    14
    Views
    990

    Its best to apply for the free pro membership...

    Its best to apply for the free pro membership then once you have sufficient posts. We will be able to help you better.


    Sent from my iPhone using Tapatalk
  38. Replies
    16
    Views
    1,500

    Well, if the 3/8Ē drain blocks up then the AC...

    Well, if the 3/8Ē drain blocks up then the AC will drain right into the furnace, so technically both?


    Sent from my iPhone using Tapatalk
  39. Replies
    16
    Views
    1,500

    OHHHHhhhh, theyíve taken the condensate from both...

    OHHHHhhhh, theyíve taken the condensate from both the AC and furnace, then bushed it down to a 3/8Ē barbed brass adapter, then tried to drain it through a 3/8Ē ID clear vynal tube?

    Am I seeing...
  40. It will be louder if you do that. You are only...

    It will be louder if you do that. You are only talking about a few inches in either dimension. I would suggest you keep it bigger so you donít create issues or unnecessary noise. Let the turbulence...
  41. Replies
    3
    Views
    559

    It says you joined only 11 hours ago.... Time...

    It says you joined only 11 hours ago....

    Time sure does fly fast!

    You should join into technical conversations to build your post count up then apply for Pro membership (itís free), so we can...
  42. What drives you to want an HVAC company when you...

    What drives you to want an HVAC company when you donít know anything about the trade and apparently have no previous mechanical interests?


    Sent from my iPhone using Tapatalk
  43. Replies
    5
    Views
    415

    If you make a mistake anywhere along the process...

    If you make a mistake anywhere along the process of trying to do what you are doing then you run the risk of contaminating system, or killing the compressor. The ďHVAC guyĒ that you have may never...
  44. Replies
    14
    Views
    990

    Keep in mind also that the higher differential...

    Keep in mind also that the higher differential didnít equate to a higher flow rate if their valves arenít opening to allow for the GPM to move. Valve off the discharge to a pump and you will still...
  45. Replies
    14
    Views
    990

    The way I see it is with a higher flow rate the...

    The way I see it is with a higher flow rate the temperature rise of the glycol through the coil would be less. Because you maintain a higher temperature difference compared to the room temperature...
  46. How to find Nat' gas leak in huge bldg with tube heaters.

    Is there a local gas valve at each heater that you can close off so you can pressurize the main trunk and determine if the leak is on the main piping or an individual heater?

    Once that main pipe...
  47. Replies
    16
    Views
    1,500

    I think itís a frozen coil that is leaking into...

    I think itís a frozen coil that is leaking into the furnace.

    My screen brightness is fully down low right now so itís hard to see the details.


    Sent from my iPhone using Tapatalk
  48. Replies
    28
    Views
    1,590

    To clarify, when I say to lube it up I mean with...

    To clarify, when I say to lube it up I mean with a penetrant not grease. WD-40 or similar works well for me.

    Sand the shaft bright and smooth. Should look new when you are done. Grinder with a...
  49. Replies
    28
    Views
    1,590

    It looks like you almost got it free with the...

    It looks like you almost got it free with the puller on it. Are you hanging up at the very end there? If you were beating in it with a hammer then itís probably mushroomed out the end. It only takes...
  50. Replies
    37
    Views
    1,789

    low sub cooling with replaced condenser coil

    I was laughing because you havenít posted any actual numbers for us to see except for the split. It didnít give us much to work with. The quality of help you get is directly related to the quality of...
Results 1 to 50 of 374
Page 1 of 8 1 2 3 4