  1. Schneider Electric I/NET PCU Controller Programming Question

    I have a job where I need to modify some existing I/NET programming in a PCU controller. I have full access to connect to the controllers, see the graphical representation of the logic, access the...
  2. Replies
    1
    Views
    104

    Andover Infinity CMX240

    I posted about this previously (during the time where the website had problems), and there was a helpful video link that was posted. The entire post is now gone, and I was wanting to see about...
  3. Yeah that is why we moved Envision to a Windows...

    Yeah that is why we moved Envision to a Windows 10 computer. The Windows XP computer that they have on site was for the old Envision 1.0 system. A few years back they upgraded their control system...
  4. We typically use Niagara JACE front end devices,...

    We typically use Niagara JACE front end devices, and Cylon Auto-Matrix BACnet field devices. Cylon has another front end device called Aspect that we use from time to time as well.

    I work on the...
  5. I have worked on quite a bit of Distech, but it...

    I have worked on quite a bit of Distech, but it isnít our main line. We typically use Distech as a secondary line especially when there is LON involved.


    Sent from my iPhone using Tapatalk
  6. Rover doesnít have the ability to configure a...

    Rover doesnít have the ability to configure a LCI-I. You basically need to add it to the Intellipak by going into the CONFIGURATION menu. Once it is added, you can go into the SETUP menu to put...
  7. Alerton Envision Backup Restore & Running Envision Through JACE

    I have a customer that used to have a older Alerton Envision control system. A couple years ago, the BCM controllers were removed, and a JACE was installed. All of the Alerton controllers that were...
  8. If you already have Comm4 on site then it is as...

    If you already have Comm4 on site then it is as easy as getting a JACE with the Maxline Comm4 driver loaded, and discovering your points like you would anything else. You donít necessarily need any...
  9. I have used Maxline and it works well. However...

    I have used Maxline and it works well. However if you have LON, I wouldnít switch to Comm4. I have used it on jobs that are already Comm4.


    Sent from my iPhone using Tapatalk
  10. Replies
    5
    Views
    272

    Typically I use the backup utility at the top...

    Typically I use the backup utility at the top left of the screen to do the backup. From there it saves a zip file to my computer for that device. I just wanted to see if that included everything...
  11. Yes they make a board called a BCI-R. You will...

    Yes they make a board called a BCI-R. You will want to verify that your RTUS main board (RTM or RTRM) firmware supports the BCI-I. If it doesnít then you will need to install a new board.

    ...
  12. Replies
    5
    Views
    272

    I typically do back up the TGP2 on devices like...

    I typically do back up the TGP2 on devices like UC600s that are being used for plant control, AHU control, etc. I have a job that has like 150 VAV boxes, and some of them have custom TGP2. I just...
  13. Replies
    5
    Views
    272

    Tracer TU Backup

    When you go into Tracer TU, and completely backup a controller does it contain all of the points, and TGP2? Or is it necessary to backup the devices, and backup the TGP2 separately through the TGP2...
  14. Replies
    7
    Views
    347

    JCIman, Thanks for all of the information that...

    JCIman,

    Thanks for all of the information that is really helpful! When would you say the "gen 4" controllers were released? I am wanting to assure that I don't have any of those yet. Also what...
  15. Replies
    7
    Views
    347

    That is good information. So you are saying if I...

    That is good information. So you are saying if I have a job that has FEC controllers then they wouldn't of used CCT 13.0 on them? The highest version they would of used is 10.3? The job I am...
  16. Replies
    7
    Views
    347

    Thanks for the replies. I have taken 2...

    Thanks for the replies. I have taken 2 certification courses through JCI on the PCT stuff. However I havenít done anything with CCT since it is a branch software. I was hoping to be able to...
  17. Replies
    7
    Views
    347

    CCT/ PCT Version 13 Question

    I am about to purchase a copy of CCT 10.3. However, I just learned that CCT is moving everything towards version 13 now. I was told that any newer controller programmed with version 13 cannot be...
  18. Originally I wasnít able to. So I got with them,...

    Originally I wasnít able to. So I got with them, and then I could ping them. However I still couldnít see any devices. So IT said something about possibly having some issues between the two...
  19. Niagara AX SoftJACE BACnet Router Question

    I have a job site that is far away that I am working on remotely for one of our customers. Basically they have us moving their existing SoftJACE to a new off site virtual machine. I got the station...
  20. Johnson Controls Nexsys Control System

    I have a job site that I ran across the other day that has a whole bunch of Johnson Controls NexSys controllers. The part number on one of the controllers was NXP-FSC-01. I noticed that all of...
  21. I contacted my vendor about the Andover Infinity...

    I contacted my vendor about the Andover Infinity driver, and he told me that it is VERY slow, and the front end needs to still be intact. I am being told that someone removed the front end from the...
  22. Replies
    11
    Views
    600

    The network wiring is something that I looked at...

    The network wiring is something that I looked at on this job when we bid it. It was definitely the wrong wiring for any RS485 protocol. It had the wrong impedance, the wrong capacitance, the wrong...
  23. Replies
    11
    Views
    600

    Automated Logic to Niagara 4 Question

    We bid a job recently to upgrade a old Automated Logic system at a old Target store. We are bidding against a competitor that claims that they can integrate all of the existing Target controllers...
  24. Replies
    15
    Views
    2,394

    Would you mind sharing this with me as well? I...

    Would you mind sharing this with me as well? I tend to use PCT most of the time, but having this version of CCT would definitely be handy. My email is on my profile. Thank you!


    Sent from my...
  25. Andover Controls - LCX810 Controller Connection

    I ran into a job site where there is a old Andover LCX810 Infinity controller. I have been told that the front end was removed years ago. So basically there is a building full of old Andover...
  26. I believe I got this working correctly. Thank...

    I believe I got this working correctly. Thank you for the assistance. The only thing I noticed was the BOOT version still remained at version 1. Is that an issue? I noticed that the BOOT version...
  27. Thank you for your reply. So basically upgrade...

    Thank you for your reply. So basically upgrade the system build first, backup the controller, load the firmware, and restore the backup? Does this process upgrade the boot version as well?
  28. Trane UC-210 VAV - Full Software Upgrade

    I have a job site that has quite a few UC210 VAV controllers. The UC210 VAV controllers on this job site were the very first version of UC210 VAV controllers when they first came out. The firmware...
  29. Replies
    6
    Views
    349

    Trane makes a retrofit kit for a D series box...

    Trane makes a retrofit kit for a D series box that replaces those older style air valves with a jack shaft and new flow ring. You need about 16Ē-18Ē of clearance from the inlet of the VAV to fit the...
  30. Replies
    6
    Views
    349

    Typically on these 1989 VAV boxes you would have...

    Typically on these 1989 VAV boxes you would have a manual speed selector for the fans. It was simply a 3 position switch that would apply voltage from the fan relay to the selected winding in the...
  31. Replies
    483
    Views
    116,647

    No unfortunately I donít have either software...

    No unfortunately I donít have either software program. Typically the sites that I have with Alerton have something like Envision loaded on a computer. I am being told that this site doesnít have...
  32. Replies
    483
    Views
    116,647

    I have a customer that has approached us in...

    I have a customer that has approached us in regards to their existing Alerton system. Every Alerton system that I have worked on has a computer loaded with the Envision software. I am being told...
  33. The error only shows up when the unit is placed...

    The error only shows up when the unit is placed back into BAS/ Tracer control. When it is under local control the error goes away. The error can be seen in the controlling setpoint status sub menu...
  34. The way that Bolt950rider states it above is how...

    The way that Bolt950rider states it above is how manufacturers like Carrier and Trane recommend that you setup a system with a bypass damper. Essentially when you drive all of your VAV boxes to...
  35. I have always been told that the area before the...

    I have always been told that the area before the bypass damper is a bad place for the sensor because the static pressure fluctuates (turbulence) too much because of the bypass damper moving back and...
  36. Trane Intellipak Comm4 TCI Integration Question

    I have a job site that has a couple Trane Intellipak RTUs integrated over Comm4 to a JACE that will never go into the economizer mode when under BAS control. I noticed that both of the units show an...
  37. Replies
    9
    Views
    1,355

    Thanks for the information! My support channel...

    Thanks for the information! My support channel just released a patch for my version of 4.7 that stated that it addressed security problems, but after applying the patch it seems that this issue has...
  38. Replies
    9
    Views
    1,355

    Thank you! That is good information. We use...

    Thank you! That is good information. We use American Auto-Matrix JACES, so it sounds like they may have the same issue. I know they just released a new version of 4.7, but it didnít mention...
  39. In order to connect BACnet to a Microtech III you...

    In order to connect BACnet to a Microtech III you need to install a communication module on the side of the Microtech III controller. From there you will get things setup by going into the BMS menus...
  40. Replies
    14
    Views
    1,336

    No the customer never went with it. There was a...

    No the customer never went with it. There was a change of management as we went through the process. They decided to stick it out a little longer with INET.


    Sent from my iPhone using Tapatalk
  41. Replies
    10
    Views
    718

    Yes there is a exhaust fan commissioning menu...

    Yes there is a exhaust fan commissioning menu with a EF Ctrl type and remote EF speed setpoint. The EF Ctrl type will need to be set to speed net to change the exhaust fan speed. However if there...
  42. Replies
    10
    Views
    718

    Need Help With Daikin Controls

    What is your SAF Ctrl currently setup for right now? It is located in the SAF commissioning menu. You get to this menu by inputting the service/ factory password. If you want this make up air unit...
  43. Replies
    9
    Views
    1,355

    811277 I just thought I would attach my screen...

    811277

    I just thought I would attach my screen shot as well. It looks pretty much the same as yours. The one thing that I did notice in my particular version of 4.7 is that the LUCID theme is...
  44. Replies
    9
    Views
    1,355

    I am having this same exact issue on a site that...

    I am having this same exact issue on a site that was recently upgraded from 4.4 to 4.7. I recommissioned the JACE and the problem came back after about a day. My screens look similar to yours but I...
  45. Does anyone have a copy of the...

    Does anyone have a copy of the installation/operation/programming guide for a UC210 VAV controller? I am having trouble finding manuals for some of the newer controllers.

    Thanks for the...
  46. The VAV controller in question is shown below....

    The VAV controller in question is shown below.
    810871
  47. Tracer TU Questions and UC210 VAV Question

    I have a customer who has the Tracer TU service tool. I was wondering what all items should be backed up per device. I see there is a way to utilize a backup utility to create a ZIP file. So I...
  48. Replies
    9
    Views
    836

    I havenít tried this using PCT, but it appears...

    I havenít tried this using PCT, but it appears that your IP port is setup as standard. In order to get a JACE to act like a router, I have had to change the IP port from standard to BBMD. I hope...
  49. Replies
    7
    Views
    725

    Yes that is exactly what you need. Sent...

    Yes that is exactly what you need.


    Sent from my iPhone using Tapatalk
  50. Replies
    2
    Views
    339

    Have you tried using the N4 dashboard service,...

    Have you tried using the N4 dashboard service, and using a dashboard pane to add a web chart to? I have done this on some jobs, and the customer can just pull and drag the points he wants from the...