Search:

Type: Posts; User: Juan Madera

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Thread: AHR show

    by Juan Madera
    Replies
    3
    Views
    277

    AHR is/was a great show. I fear that such events...

    AHR is/was a great show. I fear that such events are going to be history, sadly. If not Wuhan Flu, then another engineered plague will arrive and as the deep state is feeling its oats over the...
  2. Looks like a swivel mount for a camera... The...

    Looks like a swivel mount for a camera... The wire probably goes to a wall wart transformer somewhere.....
  3. Replies
    16
    Views
    922

    I got really tired of plumbers just setting a...

    I got really tired of plumbers just setting a water heater, plumbing the gas and demanding that we vent and gas. This with absolutely no consideration of WHERE the vent would be run and terminated......
  4. Sounds like velocity noise to me. Could be a...

    Sounds like velocity noise to me. Could be a pinch in the line inside the wall.
  5. Unless you have a need for hot water somewhere...

    Unless you have a need for hot water somewhere else, boiler and fan coil are much more expensive and fussy. This from a guy that has installed and loves radiant floors.

    I'd spring for a fully...
  6. Replies
    8
    Views
    250

    Expansion tank after the pump? That'll do it.

    Expansion tank after the pump? That'll do it.
  7. This? ...

    This?

    https://www.homedepot.com/p/Speedi-Products-1-2-Gal-Water-Base-Duct-Mastic-Sealant-AC-DMS-0-5/202907021
  8. Piston is a fixed orifice. That dog don't hunt.. ...

    Piston is a fixed orifice. That dog don't hunt..

    My thoughts are moisture, just a wee bit circulating in the system and freezing in the orofice, then passing thru.

    Based on your experience...
  9. Replies
    23
    Views
    1,661

    Have worked on old Henry RF 13.56mHz generators...

    Have worked on old Henry RF 13.56mHz generators in the 5-10kW class. Big tubes. Vicious bite over fairly long distances. Had 3 phase mercury displacement contactors. Those were fun when they exploded...
  10. If Amazon can use battery power for the 100,000...

    If Amazon can use battery power for the 100,000 vehicles on order and make their even more demanding delivery runs, I'm sure that they will work as a service van as well. At least in an urban...
  11. Try contacting a chimney flue relining company....

    Try contacting a chimney flue relining company. They have a technique for inserting an inflatable "sausage" and pumping mud in the annulus. Then they pull the liner. Might be a save in your case if...
  12. If this is an antique brick chimney, it is...

    If this is an antique brick chimney, it is probably not lined with a clay liner. Is this the case?

    As to the vent minimum, as you do have a 40' tall chimney, I'd say call the Mfg and explain your...
  13. Built a "hypocaust" heating system eh? Bare...

    Built a "hypocaust" heating system eh?

    Bare dirt on the bottom is going to be an issue. Is it a large enough space to crawl into?
  14. Replies
    18
    Views
    2,069

    This?...

    This? https://www.floormat.com/heated-mats/foot-warmers/heated-chair-mats/
  15. This tool:...

    This tool: https://remstoolsusa.com/rems-560020-powersaw-anc-reciprocating-saw-set/

    Threader: https://remstoolsusa.com/rems-540027-amigo-2-compact-hand-threader-set-1-2-2/

    Cutting oil, clear,...
  16. Replies
    52
    Views
    1,314

    Got a 277 buzz once from leaning against an EMT...

    Got a 277 buzz once from leaning against an EMT conduit in an elevator room. I let Otis know. They fixed it.

    When I was kid, I remember an electrician using two fingers on one hand testing for...
  17. Nickle lining of the evaporator flaking off...

    Nickle lining of the evaporator flaking off perhaps?
  18. Replies
    51
    Views
    1,652

    Cl and F are both highly reactive. In fact F is...

    Cl and F are both highly reactive. In fact F is the more reactive of the two. Why is it that only Chlorine is the only demon in the atmosphere? CFC's replaced by HFC's....

    And remember that R12...
  19. Short answer? No. Check the companies that mfg...

    Short answer? No.

    Check the companies that mfg specifically for M/H industry. M/H needs to have M/H approved equipment. Intertherm and Coleman are the two biggies.
  20. Replies
    91
    Views
    2,176

    Second that opinion on the W2 (lost the like...

    Second that opinion on the W2 (lost the like button again!)
  21. Replies
    91
    Views
    2,176

    All of my rigs were Pickups with utility bodies...

    All of my rigs were Pickups with utility bodies and purpose built racks. 4x4 was required for NW MT in winter and to service homes out of town... Last two were new Chevys. One 2500 with a 350 and one...
  22. Replies
    19
    Views
    795

    As is it is a marginal location. Add more...

    As is it is a marginal location. Add more impediments to flow? No....
  23. Replies
    2
    Views
    293

    Tearing down the old one and new one in it's...

    Tearing down the old one and new one in it's place?

    And how old are the existing units?

    My rough guess is that you will pay 50-70% of the cost of new to properly salvage old stuff and...
  24. Replies
    40
    Views
    1,398

    In London Ontario Canada for a sales meeting with...

    In London Ontario Canada for a sales meeting with Lifebreath. (I was the rep for MT and ID) Was supposed to go to Boston the next day for meeting with HTP. Ended up being stuck in Canada for a week,...
  25. Replies
    27
    Views
    1,458

    Try facilities maint. Always happy to have a...

    Try facilities maint. Always happy to have a willing weekend worker. Swing and grave both.
  26. Replies
    23
    Views
    2,565

    ....and notice the fire sprinkler head location!

    ....and notice the fire sprinkler head location!
  27. Existing sidearm heater may not have enough heat...

    Existing sidearm heater may not have enough heat exchanger to take the full output of the boiler. Might also have a too small circulator for the flow needed.

    Is this a zone valve system or a...
  28. Quick and dirty calculation... On the coldest day...

    Quick and dirty calculation... On the coldest day of the year, does the furnace run 100% of the time and keep the interior temps up to satisfaction? If not, the current furnace is oversized. You can...
  29. Replies
    26
    Views
    1,259

    Midea...

    Midea...
  30. Replies
    61
    Views
    1,724

    My ex employer said if I took a NATE test and...

    My ex employer said if I took a NATE test and passed I'd get a raise. So, I took and passed 7 of them in two sittings. Not hard to do if you have half a brain and lots of experience. Went to the boss...
  31. Replies
    71
    Views
    2,396

    I have had very poor results with cap tubes once...

    I have had very poor results with cap tubes once they start plugging. Replaced FD, FD and Cap tube, added Supco 88 and once in a while it works Mostly it is an exercise in futility once the POE oil...
  32. Interest is as much curiosity as anything. Just...

    Interest is as much curiosity as anything. Just like to learn!

    As to pallets and resale; are there not places to run afoul with the gubmint in this endeavor? I seriously thought of this back in...
  33. in further thought on figuing this out, get a...

    in further thought on figuing this out, get a hygrometer and see what the humidity in the condo is when it is dripping. Then turn on the bathroom fans for a few days 24/7 (providing they actually...
  34. Your condensation could possibly be from the...

    Your condensation could possibly be from the moisture in your unit being pulled into the relatively cool exhaust vent and condensing there.

    I'd bet your furnace does not run a lot.. If it did...
  35. The flat termination above works well in most...

    The flat termination above works well in most locations and it is easy to install and looks SOO much nicer than the "snorkel" with PVC

    In really cold climates I prefer the concentric as it keeps...
  36. ....and that is why I asked country of origin....

    ....and that is why I asked country of origin. Wanna keep it in the Americas...

    Real Estate here is WAAAY to "frothy" unless you have an in somewhere..... (and my daughter is in RE, so we be a...
  37. Still no one has any input on chemical supplier...

    Still no one has any input on chemical supplier to the refrigerant mfgs? Curious as to who supplies and what country those suppliers are located in....
  38. Replies
    3
    Views
    478

    Bad case of delayed ignition and you will need a...

    Bad case of delayed ignition and you will need a tech to cure it.
  39. Diamonds are made artificially scarce by the...

    Diamonds are made artificially scarce by the DeBeers family. Gold? Got that. Home? yup. Looking for other stuff that might have income and appreciation in the near future.

    As to monetary...
  40. Investing in basic materials companies stocks.. Refrigerants specifically.

    Hi guys, was pondering investing in some of the basic materials companies listed on the exchanges and the thought came to me.... What is and where do the chemicals come from that go into...
  41. Take what the inspector reported to the seller...

    Take what the inspector reported to the seller and ask the seller to correct. Then have a qualified tech of your choice recheck the install.

    Is it a big national builder? One with a reputation to...
  42. Resi chiller! Probably has multiple AH all using...

    Resi chiller! Probably has multiple AH all using chilled water... Good bet they also have gas fired hydronic heat as well to the same AH or perhaps radiant floors
  43. Feel for ya... Some people are irredeemable it...

    Feel for ya... Some people are irredeemable it would seem..

    I've hired several "clean" and then watched the drift back into the addiction, drugs or alcohol.
  44. https://www.lifebreath.com/products/commercial-hea...

    https://www.lifebreath.com/products/commercial-heat-recovery-ventilation-hrv-units/
  45. Replies
    24
    Views
    769

    Both the Russians, The USA and perhaps others...

    Both the Russians, The USA and perhaps others keep smallpox virus in their deep freeze... To what purpose? Who knows...

    Most virus vaccines are very low effective yield. Take our piss poor flu...
  46. Replies
    24
    Views
    769

    The last time I possibly got a tetanus shot was...

    The last time I possibly got a tetanus shot was in '86 when I blew my ankle out in a scaffold collapse. My understanding is that as tetanus is EVERYWHERE, every time I cut my finger on something...
  47. Replies
    24
    Views
    769

    Current regime is for a child to get 79...

    Current regime is for a child to get 79 vaccines!! More coming, such as the covid.

    ALL of them have a lot of Aluminum, each one has much more than the EPA says is safe for humans by a factor of...
  48. Replies
    29
    Views
    848

    Supco 88...... Marvel Mystery Oil?

    Supco 88...... Marvel Mystery Oil?
  49. Replies
    5
    Views
    507

    Frost of no concern if the SH is 20F at the...

    Frost of no concern if the SH is 20F at the compressor...

    Does this system have EPR's?
  50. Was it inspected by the local building...

    Was it inspected by the local building department? If so, you are likely ok. Rules differ different locations and even from inspector to inspector. Hate
    it, but we all want a "daddy," eh?
Results 1 to 50 of 1000