    Well I made sure I turn the power off and I took...

    Well I made sure I turn the power off and I took the motor leads off the control board and went to common to ground and my meter made the beeping sound and showed continuity and I went down the line...
  2. Replies
    5
    Views
    469

    Thank you for the response! I was worried for a...

    Thank you for the response!
    I was worried for a minute that I spent a lot of money on a meter that was defective! And I for got to add that I did test the end coming current to the motor and I was...
  3. Replies
    5
    Views
    469

    Fieldpiece SC680 Ohm Issues

    Hello

    I have the Fieldpiece SC680 Multi Meter and I was wondering does anyone have any problems when they ohm out motors for continuity or resistance? I had ohm out a motor one day and it was a 3...
  4. So basically 0.5 will be the benchmark and until...

    So basically 0.5 will be the benchmark and until you add up all the component pressure drops and subtract that from the 0.5 to get the available static pressure then we will use that number to set my...
  5. Yes it does thank you so much!

    Yes it does thank you so much!
  6. I totally agree and thanks I would think we would...

    I totally agree and thanks I would think we would try to set it in the middle.
  7. I was learning about how to get the friction rate...

    I was learning about how to get the friction rate and how to calculate in order to do ductwork design. I know that you need the Manual J to actually get the information I need to begin to design the...
  8. Hello and thanks I was just trying to make sure!...

    Hello and thanks I was just trying to make sure! Thanks!
  9. Getting The Correct ESP From A Furnace With A PSC Motor Compared To One With A ECM?

    Hello Iím trying to see if Iím on the right path when it comes to getting the maximum operating (ESP) External Static Pressure on the new ECM Furnaces compared to the old PSC motors.

    When it...
  10. Fieldpiece Joblink Electrical Report Using The SC660 or SC668

    Hello I I have the Fieldpiece Joblink App that Iím using to get my Electrical reading by using the SC660 meter and I wanted to know how do you use that data to compare it to the clients energy bill...
  11. Wow thanks for that info!! Iíve been *****ing and...

    Wow thanks for that info!! Iíve been *****ing and moaning about those short gator clips and thatís all you had to do! 🤪
  12. Thank you so much for this info because Iím...

    Thank you so much for this info because Iím getting back into Refrigaration and I have Joblink and I noticed that they have upgraded the app and I see you could do Refrigaration and even boilers! But...
  13. Do you use the air probes with them too? If so...

    Do you use the air probes with them too? If so where do you place them? And do you use the MesureQuick App or Joblink App with them?

    Thanks
  14. Has Anyone Use The Fieldpiece Joblink Probes On Refrigaration Equipment?

    Has anybody use the Fieldpiece Joblink probes on any refrigaration equipment? I notice it has that capability but I have not seen it done or thereís no YouTube video on it.
  15. Do you use your air probes? And if so where would...

    Do you use your air probes? And if so where would you place them? Thanks
  16. Has Anyone Use The Fieldpiece Joblink Probes On Refrigaration Equipment?

    Has anybody use the Fieldpiece Joblink probes on any refrigaration equipment? I notice it has that capability but I have not seen it done or thereís no YouTube video on it.
  17. Iíve learn recently that the SC660 is being...

    Iíve learn recently that the SC660 is being discontinued and they are replacing it with the SC668.
  18. Lmao!!! Right!!!

    Lmao!!! Right!!!
  19. Yes they are pushing these damn tools out and...

    Yes they are pushing these damn tools out and upgrading so fast that we will be spending money twice for the same tool!!! I also have everything you have from the SDP2 & Jl2 to work with my SC660 and...
  20. Man Iím still upset!!! And now Iím finding out...

    Man Iím still upset!!! And now Iím finding out they are coming out with wireless manometers soon to go along with the JobLink that I have! I just gotten the dual port manometer that checks pressure...
  21. Iím gonna keep it and use it for back because I...

    Iím gonna keep it and use it for back because I bought the SPD2 Dual In-Duct Psychrometer too and Iím just learning that the SC660 combined with the SDP2 Iím able to get the SEER & EER of the unit....
  22. Does Anyone Have The New Fieldpiece SC680 Meter?

    Just wanted to know if anyone bought the new Fieldpiece SC680 Clamp Meter? Iím kinda piss because I just recently bought the SC660 meter to go along with my Joblink Probe set so I can make reports on...
  23. Replies
    4
    Views
    911

    Yeah Iím just finding this out I donít do too...

    Yeah Iím just finding this out I donít do too many rooftop units and I was trying to do a startup on the rooftop unit and create a report with my Joblink app.
  24. Replies
    4
    Views
    911

    Fieldpiece Probes Operating Conditions

    Good morning and Happy New Year to you all!

    I have a question as far as using the Fieldpiece Joblink in the wintertime. I was trying to do a startup on a new Carrier 48TCED Rooftop gas & cooling...
  25. Lol I do the same thing put I was preparing...

    Lol I do the same thing put I was preparing myself just Incase I need one right now. Iíve been checking out the Rescue Motors and I think I might get the Rescue Motor for truck stock but I will...
  26. So you really donít have a preference meaning you...

    So you really donít have a preference meaning you use the Rescue Motor only? Or have you ever install a Evergreen ECM motor?
  27. Which ECM Replacement Motor Do You Prefer? Evergreen or The Rescue Motor?

    Hello, Iím doing some research on which replacement ECM motor I should have as truck stock The Rescue Motor or the Evergreen motor?

    Thanks
  28. Ecobee Support I heard they keep you on hold for...

    Ecobee Support I heard they keep you on hold for hours and the never get back to you! I love the product but if this the case I donít know.
  29. The reason I ask this because Iíve been hearing...

    The reason I ask this because Iíve been hearing that their Tech Support and Customer Service Sucks! 😂
  30. What Do You Guys Think About The Ecobee Thermostats?

    Hello

    Iím thinking about using ecobee Wi-Fi thermostats for all my premium package deal furnace & air conditioning installs and I just wanted to get some feedback on this thermostat.

    Thanks!
  31. Thanks! I will try that next time Iím still...

    Thanks!
    I will try that next time Iím still playing around with them!
  32. Fieldpiece Joblink Pysychrometer Probe Placement When Testing A Rooftop Unit?

    I was wondering whatís the best location to put your psychrometer when youíre working on a rooftop unit? I ask this because the other day I was using them at this store I use a ladder to put the...
  33. Replies
    31
    Views
    3,068

    Thanks for the info I got them all updated and...

    Thanks for the info I got them all updated and theyíre working now! I donít even get that update message anymore too!

    Thanks Again!!!!
  34. Replies
    31
    Views
    3,068

    Iím having issues too! Iíve been trying to...

    Iím having issues too!
    Iíve been trying to update with the firmware and it keeps telling me it needs updating after I updated them and now my clamps or my pressure probes wonít come on now!

    Iím...
  35. The app was telling me to add more refrigerant...

    The app was telling me to add more refrigerant because the calculations I got off my SMANís I took that info and calculated it on the app and again It was telling me I was low on refrigerant and to...
  36. I just wanted to see if the app was in sync with...

    I just wanted to see if the app was in sync with my SMANís and it was.
  37. It was a fix orifice Unit And I use the check...

    It was a fix orifice Unit And I use the check charge app too!
  38. Ok my friend!

    Ok my friend!
  39. Thanks for the response!

    Thanks for the response!
  40. Checking Superheat and Subcooling on a new A/C Install

    Hello

    I wanted to know on a brand new A/C Install when is the best time to check superheat (piston) or Sub-cooling (TXV)? I would assume you should wait until the system stabilized but I did that...
  41. Whereís A Good Location On A Down Flow Rooftop Unit To Measure Return Wetbulb Temper

    Hello

    I wanted to know where on a Downflow rooftop unit do you measure return web bulb temp at? By the return grille in the ceiling? Or somewhere inside the rooftop unit itself?

    Thanks!
  42. Replies
    34
    Views
    20,552

    Hi I have a SMAN Serial # 13100920 and I just...

    Hi I have a SMAN Serial # 13100920 and I just want to know how do you know how old this particular model is? Thanks!
  43. Trying to figure out how old are my SMAN2 Gauges Are??

    I have A SMAN2 gauge serial # 13100920 and Iím trying to see what is the manufacturers date.

    Thanks!
  44. Thank You! That Was Exactly What I Needed!...

    Thank You!

    That Was Exactly What I Needed! Just Pick It Up!!
    Thank You Very Much!!!!
  45. Rheem Model # RGDG-07EUER New Control Board Issue

    Good Morning

    Iíve Been Working On A Old 1994 Rheem Model# RGDG-07EUER Furnace That The Original Board Had Fried Causing The The Hot Surface Igniter Not Being Able To Light Up. I Replaced The...
  46. What Is The Lowest Temperature Recommended For Evacuating A A/C System?

    I Wanted To Know Is There A Outdoor Temp Limit To Use Your Vaccum Pump To Evacuate A A/C System?




    Thanks!
  47. Replies
    22
    Views
    3,727

    Thanks Again! Iím Working For A Insurance...

    Thanks Again!

    Iím Working For A Insurance Company And They Requires Me To Meg Out The Blower, Inducer, And Compressors When I Go Out And DonA Claim And I Want To Make Sure I Have The Right Tool...
  48. Replies
    22
    Views
    3,727

    Ok I Think In The Morning Iíll Go Up To Johnstone...

    Ok I Think In The Morning Iíll Go Up To Johnstone Supplyís Motor Shop And Have Them Test It For Me Thatís Where I Bought It At Anyway. Thanks For The Reply!!
  49. Replies
    22
    Views
    3,727

    I Did That And The Light Shot Straight To Bad!...

    I Did That And The Light Shot Straight To Bad! And The Unit Was About 2 Yrs Old. Can The Insulation Be That Bad Within 2 yrs Time?
  50. Replies
    22
    Views
    3,727

    Well I Ask That Question Because Iíve Been...

    Well I Ask That Question Because Iíve Been Testing It And It Seems Like It Always Reads Bad Even On A New Motor Or Maybe Iím Doing Something Wrong.