Search:

Type: Posts; User: kontrolphreak

Page 1 of 20 1 2 3 4

Search: Search took 0.10 seconds.

  1. Replies
    10
    Views
    571

    Will also have to reflect the changes in...

    Will also have to reflect the changes in Sitebuilder.

    kontrol out
  2. Replies
    10
    Views
    562

    Used Visio for over a decade then went back to...

    Used Visio for over a decade then went back to AutoCAD at Siemens a couple of years ago and actually after getting back into it preferred CAD as long as someone else is purchasing it. Know in the PLC...
  3. Replies
    28
    Views
    1,231

    The Siemens ADAPT statement has to now be...

    The Siemens ADAPT statement has to now be individually licensed per controller. From what our OM told us when I was with them, some outside entity had developed it and the blanket license for all the...
  4. Replies
    5
    Views
    590

    Yes the ACH580 does have software on ABB's...

    Yes the ACH580 does have software on ABB's website for configuration. New keypadtdisplay also is more detailed than old 550 making startup easier as well.

    kontrol out
  5. Replies
    64
    Views
    9,243

    Got it and responded. kontrol out

    Got it and responded.

    kontrol out
  6. Replies
    64
    Views
    9,243

    I would be interested in any books you have. My...

    I would be interested in any books you have. My email is in my profile.

    kontrol out
  7. Replies
    3
    Views
    1,226

    If you're going to replace the proprietary...

    If you're going to replace the proprietary controllers to BACnet, why would you use KMC? Just install whichever line of BACnet controllers you represent.

    kontrol out
  8. Replies
    192
    Views
    17,945

    Lin is it only Modbus RTU or is it also capable...

    Lin is it only Modbus RTU or is it also capable of converting Modbus TCP to BACnet objects?

    kontrol out
  9. Lots of programmers transition back to tech...

    Lots of programmers transition back to tech roles. It's the engineers I worry about, many were just young guys out of college with no field experience so options will be slim once all the tech roles...
  10. Replies
    12
    Views
    746

    Appears to be a common misconception of butterfly...

    Appears to be a common misconception of butterfly valve flow rate. Most butterfly valve vendors make a 0-60% butterfly valves for modulating control.

    https://youtu.be/wwFKn0EwvRQ

    They need to...
  11. A big multinational from Germany already moved...

    A big multinational from Germany already moved graphics 100% to India about 6 months ago and just informed US offices programming is now going to India as well. I expect engineering next and techs to...
  12. Replies
    24
    Views
    1,370

    eteam sent you an email. I have booth a Bluetooth...

    eteam sent you an email. I have booth a Bluetooth and hardwire CON768.

    kontrol out
  13. Replies
    46
    Views
    2,355

    Siemens graphics and programming is now done...

    Siemens graphics and programming is now done overseas, engineering to follow and when they work out how to use VR goggles onsite bodies will be just eyes and ears for remote techs.

    I have worked...
  14. Replies
    14
    Views
    599

    Version 2 had no standards on graphics, whatever...

    Version 2 had no standards on graphics, whatever the programmer wanted to do in graphics. Program was monochrome. Controllers in the Pro series have green LED on inputs and red on outputs.
    ...
  15. Replies
    29
    Views
    931

    Also you can get some low draw relays such as...

    Also you can get some low draw relays such as Finder and Phoenix Contact PLC style ones or a Functional Devices RIB may have a low enough draw as well. Old school IDEC style icecubes are hogs, and...
  16. Replies
    29
    Views
    931

    I would keep the control at the BMS and the...

    I would keep the control at the BMS and the safety at the VFD. Too many things may change in regards to the controls over the life-cycle of the systems and to have to coordinate changes in multiple...
  17. Replies
    29
    Views
    931

    I would.prefer to run the vibration switch...

    I would.prefer to run the vibration switch directly to the drive and pick up the status via BACnet.

    kontrol out
  18. Replies
    1
    Views
    203

    Have you tried user: password pass: password or...

    Have you tried user: password pass: password or 12345? Maybe admin admin? Or asdf1234?

    Possibilities are endless.

    kontrol out
  19. If you search for Rainbow Sentinel Driver you...

    If you search for Rainbow Sentinel Driver you should be able to find a compatible download.

    kontrol out
  20. Replies
    59
    Views
    2,625

    Gentlemen (and I use that term loosly) let's stop...

    Gentlemen (and I use that term loosly) let's stop the squabbling and keep this thread on track.

    kontrol out
  21. Replies
    59
    Views
    2,625

    https://www.ctrlspecbuilder.com Best site...

    https://www.ctrlspecbuilder.com

    Best site online for generating comprehensive sequences, basic flow diagrams,, points lists and specs that are full featured.
    ...
  22. Replies
    15
    Views
    664

    Probably the best book on BACnet. Just the right...

    Probably the best book on BACnet. Just the right level of technical and practical knowledge. Worth the price of entry.

    The only reason Schneider has a low vendor ID is through their acquisition of...
  23. Replies
    15
    Views
    664

    Yeah the old Ibex line. Apex and Tux controllers....

    Yeah the old Ibex line. Apex and Tux controllers. Pretty basic but was solid. Was still being installed in the local area in the 2000s. The even have a BCM-Tux to bring it into BACtalk and probably...
  24. Replies
    15
    Views
    664

    Their initial offering was proprietary but the...

    Their initial offering was proprietary but the controllers you mentioned appear to be their BACnet line. Over the years I have seen some quirks with Alerton stuff but integration into a Tridium...
  25. Replies
    13
    Views
    538

    Maybe Bently Nevada has something to fit your...

    Maybe Bently Nevada has something to fit your needs.

    https://www.bakerhughesds.com/bently-nevada

    kontrol out
  26. Replies
    13
    Views
    7,505

    BTTW - Balls To The Walls, as in fan speed. TB -...

    BTTW - Balls To The Walls, as in fan speed.
    TB - Text Book, as in readings or settings.
    RFI - Request For Income, as in what the majority really are.
    BPE - Back Pocket Engineering, as in what...
  27. At this point I believe Siemens to Computrols....

    At this point I believe Siemens to Computrols. From what I understand they have controllers in BTL testing currently, maybe once they are approved it will be Siemens to BACnet via their IP...
  28. https://m.youtube.com/watch?v=VvowxHngu0I ...

    https://m.youtube.com/watch?v=VvowxHngu0I

    Yeah, I had a buddy about 10 years ago that was a dealer for a short period. I do recall they were on the high side but they did have a couple of...
  29. https://www.computrols.com/integration/computrols-...

    https://www.computrols.com/integration/computrols-siemens-integration-solution/

    kontrol out
  30. I would concentrate and prioritize on getting the...

    I would concentrate and prioritize on getting the sick logo designed. Everyone knows that perception and knowing the TLAs is 90% of the game.

    kontrol out
  31. Replies
    0
    Views
    372

    ABB ACH580

    Looking to add an ACH580 to my drive test bench. If anyone has a line on a 1HP 208VAC ACH580 at a reasonable price drop me a line.

    kontrol out
  32. Replies
    7
    Views
    620

    Tried to edit my post and deleted it instead. It...

    Tried to edit my post and deleted it instead. It was wrong anyways, Delta default temperature AIC is 10K2. As it also stated you can create your own AIC to match any curve, just have to convert the...
  33. The entire link or just the devices downstream of...

    The entire link or just the devices downstream of the powered down unit?

    kontrol out
  34. Replies
    11
    Views
    503

    Slaves? kontrol out

    Slaves?

    kontrol out
  35. Replies
    10
    Views
    688

    Maybe its time to bring back the pressure switch,...

    Maybe its time to bring back the pressure switch, what is old is new again.

    kontrol out
  36. Replies
    5
    Views
    378

    ORCAview BACnet/Ethernet doesn't use ports....

    ORCAview
    BACnet/Ethernet doesn't use ports. BACnet/IP does.
    Net1 and Net2 are IEA-485 connections.

    kontrol out
  37. Yes, controller firmware must match ORCAview rev...

    Yes, controller firmware must match ORCAview rev for full functionality.

    kontrol out
  38. By default ORCAview uses BACnet/Ethernet to...

    By default ORCAview uses BACnet/Ethernet to connect to the system, at least it did 10 years ago. Enable Ethernet on the BAS-RT and see if that works.

    If you can discover the BAS-RT and not the...
  39. Replies
    11
    Views
    762

    Doubt it is a polarity issue if it is persistent...

    Doubt it is a polarity issue if it is persistent even when the terminal block is disconnected from the drive. Appears to be an EMF issue. Another thing would to be run a temporary commute between the...
  40. Replies
    11
    Views
    762

    Throw a o-scope on it and have a look at the...

    Throw a o-scope on it and have a look at the electrical characteristics of the signal with and without the VFD energized. At least that way you have the evidence to show the VFD supplier that it is...
  41. Replies
    19
    Views
    2,443

    Good to see you're making progress. Do not forget...

    Good to see you're making progress. Do not forget to learn about the equipment you will be trying to program, it's interactions with other (sub)systems as well as the fundamental foundation of...
  42. Both use rebranded older generation of Viconics....

    Both use rebranded older generation of Viconics.

    kontrol out
  43. Replies
    3
    Views
    383

    https://thebacnetinstitute.org/ kontrol out

    https://thebacnetinstitute.org/

    kontrol out
  44. Replies
    3
    Views
    383

    http://www.atplearning.com/product/1333/hvac-contr...

    http://www.atplearning.com/product/1333/hvac-control-systems-online-instructor-resources

    http://www.atplearning.com/product/1330/hvac-control-systems
    ...
  45. Replies
    5
    Views
    436

    If it is a DFM on LinkNet, the points will have...

    If it is a DFM on LinkNet, the points will have the Dev# of the controller the expander is under and the object # of the DFM address as indicated above.


    DSC-1616 BACnet Dev# 13690

    DFM-404...
  46. Replies
    5
    Views
    436

    If that small controller is a DFM (Delta Field...

    If that small controller is a DFM (Delta Field Module - Linknet IO Expander) those point object numbers will actually be DFM address # 100 plus point number. As this is the only "small controller"...
  47. BTW, good to hear from you. Your website...

    BTW, good to hear from you. Your website accessibility has been hit and miss during the Mexican beer fest. Can you send me the latest firmware and loader for your BACnet router. Just purchased one in...
  48. Not a Niagara slinger, but for every BACnet...

    Not a Niagara slinger, but for every BACnet AWS/OWS I have slung I prefer first method, now that being said none of the systems I have used in the past have licensing scheme like Niagara.

    kontrol...
  49. Replies
    58
    Views
    2,072

    The ole Betamax versus VHS argument. Porn...

    The ole Betamax versus VHS argument. Porn industry settled that. Maybe they'll do the same for LON versus BACnet.

    kontrol out
  50. Replies
    58
    Views
    2,072

    Same per BTL listed drives, points list will be...

    Same per BTL listed drives, points list will be same for any BACnet integration and standard objects will be interoperable.

    kontrol out
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4