  1. Replies
    4
    Views
    332

    If you open the config.bog file on the station in...

    If you open the config.bog file on the station in the User Home under your File System the little icon (box with unlocked lock) along the header becomes usable. There are a couple options 1 is force...
  2. Vykon Pro - Min Max Avg block not configured...

    Vykon Pro - Min Max Avg block not configured properly. My guess
  3. Thread: N4.10

    by mechmike2
    Replies
    3
    Views
    273

    N4.10

    How's N4.10? Been going with N4.7.
  4. Replies
    3
    Views
    392

    Thanks for that info. Appreciate it.

    Thanks for that info. Appreciate it.
  5. Replies
    3
    Views
    392

    JCI NSB8--- Series Wall Sensors

    Installed some of these sensors on a number of RTU's. Some of them display the setpoint as Absolute (74) others display the setpoint as Relative (±1). Can't figure out how make them consistent....
  6. Replies
    14
    Views
    914

    Honeywell T-775 (4 relay), Tekmar Pump Sequencer,...

    Honeywell T-775 (4 relay), Tekmar Pump Sequencer, Done.
  7. Replies
    3
    Views
    249

    Bacnet. All null except for fallback which is...

    Bacnet.

    All null except for fallback which is Auto. When Emergency Override is released output is Fan Only at default. No matter which priority is set at Auto below 8 that comes out at output as...
  8. Replies
    3
    Views
    249

    IntelliPak to N4 problem

    Did an Intellipak to FX 80 integration couple years ago. Had to add the Heat-Cool BAS mode point to do some sequencing during winter months. Sequences have worked well for their needs.

    Got a call...
  9. Same thing happened to me. Pulling my hair out...

    Same thing happened to me. Pulling my hair out for hours looking through the manual and menus.
  10. Replies
    9
    Views
    757

    Sent a couple things that might help.

    Sent a couple things that might help.
  11. Got through to support. Add 1 to each enumerated...

    Got through to support. Add 1 to each enumerated point. Don't understand why the point list in their manual can't list proper points but whatever.
  12. New York YLAA Chiller-Status and Fault Enumerations wrong

    Just did Bacnet integration for chiller to Niagara, all went well except the Status and the Fault enumerations from the manual do not match what the unit is doing. Almost seems I need to add 1 (0 is...
  13. Thanks for the input I have never run into this...

    Thanks for the input I have never run into this before. Don't understand why it is such a big deal (Other than life safety). Input from fire alarm system causes system to go into a particular...
  14. Running into same issue. Engineer says that since...

    Running into same issue. Engineer says that since smoke exhaust sequence (20 year old sequence) calls for AHU to run at 100% OA and VAV boxes to go 100% open in smoke exhaust mode that ALL...
  15. Replies
    8
    Views
    422

    If you have copied the station to your User home,...

    If you have copied the station to your User home, expand My file system, expand User Home, expand stations, expand shared (in station you want px from), expand px folder and copy it then paste it in...
  16. Thread: Pot Farms

    by mechmike2
    Replies
    19
    Views
    1,953

    Pot Farms

    Now its CO2 control.
    No such thing as a modulating inert gas valve. They wanted 1300 ppm, it appears (to me) that the pressure from tank is so high that it over-saturates the room and valve is just...
  17. Replies
    0
    Views
    370

    Tecogen Chiller

    Anyone done a Bacnet integration to a Tecogen Chiller? Looking for literature, essentially what points are Alarms. Lots of points but vague naming. Literature is non-existent.
  18. These are Armstrong pumps.

    These are Armstrong pumps.
  19. Replies
    5
    Views
    1,140

    Sorry should have said --- Open install version...

    Sorry should have said --- Open install version 4.7 on c drive. Open Workbench User Home COPY station (from station folder). Open Deamon User Home PASTE station into station folder.
  20. Still waiting on balancer but the flow reading...

    Still waiting on balancer but the flow reading from pump VFDs is close to flow ratings on total valves open. I am surprised seeing that the pump just seems to look at differential across the pump,...
  21. Ended up integrating to pumps, which have a flow...

    Ended up integrating to pumps, which have a flow reading, and using that reading a network input to control the valve. Hate not using hardwired sensor but it works and I default to a minimum position.
  22. Replies
    5
    Views
    1,140

    Had same problem. Open install version 4.7 on...

    Had same problem.

    Open install version 4.7 on c drive. Open Workbench User Home copy station (from station folder). Open Deamon User Home copy station into station folder.
  23. best way to control bypass valve without a flow meter

    They deleted flow meter but want bypass to support a minimum flow. Was trying DP but pumps just ramp down, knew it wouldn't work. Thinking no valves open = 30% 1 valve open= 20%...etc. anyone have a...
  24. Replies
    8
    Views
    1,188

    So if I had an engineer that wanted a months...

    So if I had an engineer that wanted a months worth of data I could set up a Rdbms network to export the history to a spare WB licensed laptop that I could leave on-site? Is there a way to make all...
  25. Batch History Export to PC - Not Supervisor

    Is there a way to do batch exporting of trends to a customers PC. Rdbms seems the way to go but is there another way? Other than exporting 1 trend at a time.
  26. If I recall properly the PSIO modules have a...

    If I recall properly the PSIO modules have a battery, if the battery dies and you shut off power you are SOL. Happened to me once. Local distributor was able to reprogram board this was appx. 10...
  27. Numeric Unit Conversion. Kit control palette

    Numeric Unit Conversion. Kit control palette
  28. Thread: Evapco Tower

    by mechmike2
    Replies
    3
    Views
    556

    What is the issue- Device goes down after max. 5...

    What is the issue- Device goes down after max. 5 minutes. When device is up points are constantly faulting, not simply "transaction timeout #--" but going down, then come back. When device stays down...
  29. Thread: Evapco Tower

    by mechmike2
    Replies
    3
    Views
    556

    Evapco Tower

    Have a "farm" with a new Evapco cooling tower that I am integrating into niagara (Webs 4.7). Tower has an ALC UPC as a gateway and the thing just won't co-operate. It is on a segment with some...
  30. Replies
    0
    Views
    325

    Spyder sensor failure alarm

    Is there an easy way to generate an alarm if a sensor goes invalid (nan)?

    Looking at a String Writable with a String COV Alarm Ext to alarm if point goes nan. But looking for other/better options.
  31. Replies
    2
    Views
    529

    I would guess you have a px that has bound ords...

    I would guess you have a px that has bound ords that don't exist. I would recheck bound labels on graphics to be sure ords are accurate.
  32. Replies
    11
    Views
    1,562

    I'd also like to check out your guide. Email in...

    I'd also like to check out your guide. Email in profile. Thanks
  33. no license fee if "major" version remains the...

    no license fee if "major" version remains the same. ie... if you upgraded to a 3.6 version (you SHOULD upgrade to 3.8 version) then license upgrade fee comes in. be ready for java issues in 3.5
  34. Replies
    24
    Views
    2,724

    Eagle/CIPer 50

    Are the HW Eagle controller and the HW CIPer 50 controller the same thing?

    Anyone use them?

    What do you think?
  35. Replies
    13
    Views
    2,101

    Has anyone got this Web Launcher to work on a...

    Has anyone got this Web Launcher to work on a Mac? Only downloads I see are Windows.
  36. If you can access the platform just copy the...

    If you can access the platform just copy the module from the Jaces file system into modules of the Webs version your running using file transfer client
  37. Replies
    5
    Views
    516

    If I recall correctly in Engineering Mode, or...

    If I recall correctly in Engineering Mode, or not, Action--Generate NV's. Should be good to go.
  38. Replies
    2
    Views
    720

    Don't sweat the small stuff, MSTP sucks.

    Don't sweat the small stuff, MSTP sucks.
  39. Replies
    1
    Views
    337

    I have commissioned numerous Vykon Jaces using...

    I have commissioned numerous Vykon Jaces using Webs. As long as you have necessary modules needed to run Station you should be good to go.
  40. Thread: N4 Graphics

    by mechmike2
    Replies
    9
    Views
    1,122

    Make sure there are no incorrect points on you...

    Make sure there are no incorrect points on you schedule px
  41. Replies
    2
    Views
    488

    Temperature Setpoints are relinquish default. I...

    Temperature Setpoints are relinquish default. I have yet to figure out how to write to Air Flow Setpoints, the 3113 never works for me
  42. Replies
    7
    Views
    1,214

    Believe those Trane units can use a conventional...

    Believe those Trane units can use a conventional thermostat or A Trane ZSM style sensor. If conventional tstat is wired to ZSM inputs then either nothing would happen or bad things would happen,...
  43. Replies
    9
    Views
    2,447

    I gave up.

    I gave up.
  44. Replies
    9
    Views
    2,447

    Honeywell Buildings Forum

    Has anyone figured out how to access this site since they changed it?
  45. Replies
    2
    Views
    562

    Version?

    Version?
  46. The issue I seem to be having is when my boxes...

    The issue I seem to be having is when my boxes are in Unoccupied they occasionally seem to go back into Occupied. I am looking at trending of Heat and Cool Setpoints which during Unoccupied times are...
  47. In curious about Tuning Policy settings on the FX...

    In curious about Tuning Policy settings on the FX controllers (PCV and PCG) integrated into a Jace. Any recommended settings from Johnson?
  48. Replies
    1
    Views
    561

    New Trane Intellipak

    Have a new unit that is acting strange. Unit has Hydronic HW coil, have Daytime Warmup disabled, Morning Warmup enabled. Past 2 nights customer left unit Occupied all night but in looking at trends...
  49. How about writing to Flow set points in Niagara...

    How about writing to Flow set points in Niagara when using the PCV controllers after programming with PCT tool? Was told to write to the Default property but there isn't one. Present value doesn't...
  50. Replies
    13
    Views
    2,115

    I never use 1-3 on MSTP no matter what brand....

    I never use 1-3 on MSTP no matter what brand. Have been told "tools" use those addresses. Easy enough not to use them.