Search:

Type: Posts; User: Deathpunch0311

Page 1 of 9 1 2 3 4

Search: Search took 0.06 seconds.

  1. That’s telling you how many CFM and watts the...

    That’s telling you how many CFM and watts the motor is producing with what static pressure it’s running at.
    If your installer would have did a commissioning report you would know what static...
  2. Replies
    10
    Views
    342

    I have 25-30 capacitors on my van at any given...

    I have 25-30 capacitors on my van at any given time. From 5mfd to 80/5mfd.

    Most of the time I use a small majority (5,7.5,10, 30/5 35/5 40/5) of them

    Our parts nazi organizes them in...
  3. With it being grossly oversized it will never run...

    With it being grossly oversized it will never run at 100% and will have oil return issues for the compressor. Sweating issues the list will go on and on.

    My company is dealing with a issue like...
  4. Replies
    8
    Views
    427

    Thank you sir :)

    Thank you sir :)
  5. But he read on google he could do this!!! :)

    But he read on google he could do this!!! :)
  6. Replies
    8
    Views
    427

    Nest is garbage!!! PECMSG will come along and...

    Nest is garbage!!! PECMSG will come along and post a picture of the nest tstat that best represent what we all think of nest. They make you system do things it’s not supposed to do.

    Do yourself a...
  7. Replies
    1
    Views
    379

    My Sidejob

    Took out a 5ton put a 4ton, as per Load Calc.

    Existing ductwork was sized for a 4ton and the original contractor installed a 5ton(2309sq ft). My friend was real reluctant to down size his unit....
  8. Sad part is, it was probably size right and...

    Sad part is, it was probably size right and someone came in sized it solely on square footage.

    Let me guess, your house is somewhere around 2500sq ft?
  9. Replies
    2
    Views
    247

    If it’s in a hard lock out there’s an issue that...

    If it’s in a hard lock out there’s an issue that preventing it to run. An issue your friend needs to call their service provider to check out. Due to the site rules, NO DIY ADVICE IS GIVEN.
  10. Replies
    9
    Views
    401

    Best and worst time of my life USMC 2007-2011...

    Best and worst time of my life

    USMC 2007-2011
    :patriot::patriot:
  11. You can do flex duct or ductboard with ductboard...

    You can do flex duct or ductboard with ductboard take offs, which could be very expensive.
    For what It would probably cost to repair what’s there, you might be throwing good money after bad. But...
  12. Replies
    5
    Views
    476

    Almost sounds like a national company that has 3...

    Almost sounds like a national company that has 3 letters for a name....

    Sounds like you got screwed
  13. Replies
    10
    Views
    418

    That is not the proper way of judging if a system...

    That is not the proper way of judging if a system is low on refrigerant. A low suction pressure could be the cause of many things. Not just low on refrigerant. My advice is a get a second opinion.
    ...
  14. https://www.vemcoinc.com/myths-and-facts-of-hvac-r...

    https://www.vemcoinc.com/myths-and-facts-of-hvac-refrigerants?mode=download&file=Daikin-Chiller-Refrigerant-Myth-Fact-White-Paper_1477067819.pdf&id=89

    I found this last night
  15. Accessories always get their own transformer!!!

    Accessories always get their own transformer!!!
  16. Even Lennox’s new “quantum coils”, WHICH WEREN'T...

    Even Lennox’s new “quantum coils”, WHICH WEREN'T SUPPOSED TO LEAK, are leaking. We’ve have had to replace several this year. Lennox is getting so bad, between their leaking coils and crappy blower...
  17. Replies
    7
    Views
    453

    You are oversized How was the new unit sized?

    You are oversized

    How was the new unit sized?
  18. But doing a manual j is hard and takes too long....

    But doing a manual j is hard and takes too long. 500sqft per ton is easier and faster :)

    Please sense the sarcasm
  19. That’s not “one day worth of growth”

    That’s not “one day worth of growth”
  20. Replies
    16
    Views
    1,528

    I honestly don’t have the slightest clue as to...

    I honestly don’t have the slightest clue as to what I am looking at. South Florida tech, never seen a boiler before.

    But the pipe work looks amazing!!!
    How long did it take to install all of it?
  21. Replies
    6
    Views
    835

    My shop has 6 of them. Mainly used by our new...

    My shop has 6 of them. Mainly used by our new construction guys, they carry next to no equipment or parts. Haven’t heard any complaints from them.
  22. Replies
    22
    Views
    1,182

    I was in Orlando Friday. Man they really have...

    I was in Orlando Friday. Man they really have screwed up the turnpike. I don’t understand how ANYONE would want to work or live in a big city!!!
  23. DAN SW FL will be along shortly to assist you...

    DAN SW FL will be along shortly to assist you with this.
  24. Had an older tech tell me 20 Mississippi is about...

    Had an older tech tell me 20 Mississippi is about a pound of refrigerant LOL
  25. Would you care to go into detail on this?

    Would you care to go into detail on this?
  26. Replies
    27
    Views
    1,980

    I wish more people would use type l for their...

    I wish more people would use type l for their runs. Looks cleaner

    Beautiful install BTW
  27. Replies
    175
    Views
    69,713

    And must be involved in day to day activities as...

    And must be involved in day to day activities as well
  28. Replies
    4
    Views
    398

    Focus on the contractor not the brand!!! I’ve...

    Focus on the contractor not the brand!!! I’ve seen high end units that was poorly installed that did not perform as designed.
    In Palm city HVAC Contractors are a dime a dozen. Every time I go there...
  29. You need to someone to evaluate that duct work...

    You need to someone to evaluate that duct work too. Looks like the insulation is coming off
  30. the only reason you would need to “change the...

    the only reason you would need to “change the tonnages” for a unit is if you make significant upgrades to the building envelope, more insulation, better windows etc.

    My advise to you is get your...
  31. Replies
    11
    Views
    604

    Why do you have to work with this contractor?

    Why do you have to work with this contractor?
  32. No we only do on site load calculations. Go...

    No we only do on site load calculations.

    Go with dan. He’s real good about doing everything over the internet!!!
  33. Replies
    4
    Views
    515

    You got to be careful with some mold remediation...

    You got to be careful with some mold remediation companies. They will say “you have mold everywhere” and it will cost tens of thousands for you to fix. Most of insurance policies don’t cover mold. I...
  34. The company I work for charges $125 per ton per...

    The company I work for charges $125 per ton per the manual J and $100 for the manual D.
  35. Replies
    15
    Views
    729

    PSL that’s my neck of the woods. Find...

    PSL that’s my neck of the woods.



    Find someone that will do a load calculation and not do a like for like swap. Find someone who will go actually climb in your attic and check your duct work....
  36. Replies
    21
    Views
    2,298

    I had a an old lady, around 75-80, that was a...

    I had a an old lady, around 75-80, that was a straight up BASKET CASE!!!!

    Went to her house as a second opinion. She had a 1987 Trane air handler with a 2004 condenser. Previous company told her...
  37. Replies
    16
    Views
    1,177

    Installs lead to service 😂

    Installs lead to service 😂
  38. Ask about becoming a FSR

    Ask about becoming a FSR
  39. Replies
    13
    Views
    718

    I laughed way to hard at this

    I laughed way to hard at this
  40. I’m in Vero Beach. Unfortunately my company...

    I’m in Vero Beach.
    Unfortunately my company does not go to PalmBeach County anymore.

    But I can, along with any member on this forum, answer any questions you may have.
  41. To the OP, I am a tech in south Florida. Just...

    To the OP, I am a tech in south Florida.

    Just had a customer last week who had almost the same setup as you. 2500 square feet, no shade. Had a 5 ton unit. The ducts were NOT capable of handling 5...
  42. Replies
    14
    Views
    1,668

    I want my participation trophy too and my safe...

    I want my participation trophy too and my safe space because “I’m offended” LOL
  43. Replies
    26
    Views
    1,150

    3 ton on 1450sq foot you’re oversized. The unit...

    3 ton on 1450sq foot you’re oversized. The unit was probably short cycling and took out the compressor.

    You need to find a competent Tech that can determine the cause of the compressor failure...
  44. This morning I was doing a maintenance on an unit...

    This morning I was doing a maintenance on an unit that was 32years old. Coil was rusted worse than that. But it was running like a top. I told the customer there’s no need to replace it. It’s running...
  45. Replies
    8
    Views
    661

    Lennox recommends to seal the hole in the wall...

    Lennox recommends to seal the hole in the wall where the tstat wire comes through with some sort of a vapor barrier, foil tape, caulk etc. IT could be picking up the humidity from in the wall...
    ...
  46. All the 184xx 185xx codes have to do with the...

    All the 184xx 185xx codes have to do with the refrigerant side of the equipment. You need a competent tech to find and fix this problem!!!

    The reasons why it works after you cycle the breakers,...
  47. Replies
    8
    Views
    573

    The owners of the company can’t have big salaries...

    The owners of the company can’t have big salaries by techs fixing stuff, you should know that!!! LOL
  48. With the site rules, idk if we can tell you how...

    With the site rules, idk if we can tell you how to do it. Maybe an admin can clarify...


    The guy you found might be a one man show. There’s nothing wrong with that. He might be able to do what...
  49. Replies
    8
    Views
    573

    X2 Time for a new contractor!!!

    X2

    Time for a new contractor!!!
  50. Replies
    12
    Views
    529

    It’s a Lennox so you're getting screwed

    It’s a Lennox so you're getting screwed