  1. The condenser doesn't care if its connected to a...

    The condenser doesn't care if its connected to a piston or TXV system.

    If the compressor locked up. It could be that the indoor piston was not the right size, or that the indoor air flow was too...
  2. They would use -36 or -40 if the published temp...

    They would use -36 or -40 if the published temp was -36.3F

    Has the HOA or condo association put you in charge o reducing cost? Remember, one slip up and you could cost them a lot more money...
  3. Replies
    7
    Views
    258

    Get a qualified company in to solve your oil...

    Get a qualified company in to solve your oil burner problems.

    This is not a DIY site.

    Thread closed.
  4. Thread: Delta T help

    by beenthere
    Replies
    14
    Views
    250

    If the boiler is using outdoor reset. Then the...

    If the boiler is using outdoor reset. Then the temp delta will increase as the outside temp drops.
  5. Replies
    12
    Views
    293

    Welcome aboard.

    Welcome aboard.
  6. Replies
    11
    Views
    250

    Moved to AOP. Probably just a coincidence that...

    Moved to AOP.

    Probably just a coincidence that the A/C stopped working. Time to call in a contractor.
  7. Replies
    28
    Views
    607

    He said gas package unit. So it would make sense...

    He said gas package unit. So it would make sense that its 230 volt.
  8. Replies
    10
    Views
    288

    Moved to AOP.

    Moved to AOP.
  9. Moved to AOP.

    Moved to AOP.
  10. Replies
    6
    Views
    282

    Yes, because the thermostat doesn't know its...

    Yes, because the thermostat doesn't know its connected to a heat pump.

    Moved to AOP.
  11. Replies
    39
    Views
    4,496

    And right under where it says General Discussion....

    And right under where it says General Discussion.

    It says: Any topic. **HOMEOWNERS, Please ask your questions in the AOP forum**
  12. Moved to AOP.

    Moved to AOP.
  13. Replies
    12
    Views
    452

    Oh look. An exterior compressor warming blanket.

    Oh look. An exterior compressor warming blanket.
  14. The 700 works best when its mounted on the supply...

    The 700 works best when its mounted on the supply plenum. The 600 works the same whether its mounted on he supply or return.
  15. The longer time the furnace runs is what provides...

    The longer time the furnace runs is what provides the greater comfort. It minimizes the cool/cold draft feeling you an get right after a furnace shuts off.
  16. You can go online to Amana and check. The line...

    You can go online to Amana and check.

    The line set can be disconnected from the indoor unit and checked for leaks. By brazing the lines shut at the indoor unit, and pressurizing them with nitrogen.
  17. Replies
    11
    Views
    408

    Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  18. Replies
    20
    Views
    863

    The characteristics of limit switches that have...

    The characteristics of limit switches that have repeatedly failed. Will vary with how often they opened. Which is often determined by the reason they failed.

    So the questions you were asked do...
  19. Replies
    15
    Views
    552

    Post model number of old furnace. Your home is...

    Post model number of old furnace.

    Your home is most likely under HUD rules.
  20. Replies
    8
    Views
    406

    In heat mode, the large line is not a suction...

    In heat mode, the large line is not a suction line. Its a high pressure hot gas line. You need to connect your manifold to the true suction port to read the suction pressure.

    If you connect your...
  21. Replies
    20
    Views
    863

    Your starting post made it sound like you didn't...

    Your starting post made it sound like you didn't look for any other causes than the gas pressure. So you will get answers that either are, or seem accusing.
    The more detail you start with, the...
  22. Replies
    15
    Views
    552

    Is this heat pump and air handler approved for...

    Is this heat pump and air handler approved for mobile home use.

    How much air did the old unit move, and did it also have 15 KW of electric aux heat in it.

    You won't get the help you want here....
  23. Could be. That varies with he install.

    Could be. That varies with he install.
  24. Did you check your breakers?

    Did you check your breakers?
  25. Could be the blower motor is over heating if its...

    Could be the blower motor is over heating if its 30 years old, or the transformer. Which would have nothing to do with the gas pressure.
  26. The manifold pressure was at 3.2" which is what...

    The manifold pressure was at 3.2" which is what most manufacturers list as the min. And many furnaces do burn better at slightly less than 3.5".

    Those techs may have just been interested in...
  27. Or, an older tech that has done capping, and...

    Or, an older tech that has done capping, and knows more than just to say, you need a new furnace. After 30 years, the only thing a combustion analyzer will show, is a false high O2(unless its an old...
  28. If I was posting as a Moderator. I would be...

    If I was posting as a Moderator. I would be warning someone of a rule violation they made, or answering a site question they asked.

    So I'm only answering/posting as a member the same as you.

    A...
  29. Common at one time to cap a burner.

    Common at one time to cap a burner.
  30. Good chance the installing contractor had the gas...

    Good chance the installing contractor had the gas pressure turned down to prevent over heating.

    Dirty burners is probably the cause of the delayed ignition.
  31. Your comfort will increase a lot after you do.

    Your comfort will increase a lot after you do.
  32. Replies
    46
    Views
    1,610

    Sell 750 thousand plus a year.

    Sell 750 thousand plus a year.
  33. Replies
    6
    Views
    278

    Without being there, can't guess at leak cause. ...

    Without being there, can't guess at leak cause.

    We don't talk prices here.
  34. Replies
    23
    Views
    1,063

    Residual R22? Not if you pulled a good vacuum.

    Residual R22? Not if you pulled a good vacuum.
  35. I'm trying to figure out why you have such a big...

    I'm trying to figure out why you have such a big furnace for an 1800 sq ft house.

    You probably don't need more than a 70,000BTU furnace.
  36. Might want the installing contractor to recheck...

    Might want the installing contractor to recheck the charge.
  37. Replies
    1
    Views
    210

    Might want to use the Contractor locator map in...

    Might want to use the Contractor locator map in my sig.
  38. Should have recovered the charge, and then...

    Should have recovered the charge, and then weighed it back in.
  39. So did he correct the charge issue. A new...

    So did he correct the charge issue.

    A new thermostat won't help if he didn't.
  40. Replies
    4
    Views
    278

    Moved to AOP.

    Moved to AOP.
  41. Replies
    5
    Views
    267

    Moved to AOP.

    Moved to AOP.
  42. Replies
    11
    Views
    492

    Moved to Tech to Tech.

    Moved to Tech to Tech.
  43. Replies
    1
    Views
    237

    That is a communicating thermostat. Can't be...

    That is a communicating thermostat. Can't be wired like you think. Call the furnace installing contractor, they will know how to connect your humidifier to work like you want.

    Sorry, this is not a...
  44. Sorry, this is not a DIY site. Please consult...

    Sorry, this is not a DIY site.

    Please consult an electrician.

    Thread closed.
  45. Replies
    20
    Views
    585

    Leave both the upper and lower return grilles...

    Leave both the upper and lower return grilles open.
  46. Replies
    20
    Views
    585

    61700 BTU an hour output and a 60F temp rise,...

    61700 BTU an hour output and a 60F temp rise, only requires 952 CFM. So either your greatly over fired, not really moving 1100 CFM, or your digital thermometer is really inaccurate.
  47. Best to have the thermostat con troll staging...

    Best to have the thermostat con troll staging only. No need for it to time up to second stage. Can actually lessen comfort. Have them reset it.
  48. Thread: Carrier 48TC

    by beenthere
    Replies
    6
    Views
    359

    Whoa, take it easy. You posted your question the...

    Whoa, take it easy. You posted your question the equipment/Building owner section, where tech aid aid is not permitted.

    Moved this to Tech to Tech for you.
  49. Replies
    22
    Views
    641

    Yeah, nothing dumb about riding a 1000 pound...

    Yeah, nothing dumb about riding a 1000 pound animal and thinking you are in control. :grin2:
  50. Do you also turn yourself into the police...

    Do you also turn yourself into the police everytime you speed in your vehicle and they don't see you.

    Ever get a tip from a customer? If so, did you report it to the IRS and pay tax on it.