Search:

Type: Posts; User: Norriski Tech

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Replies
    10
    Views
    310

    alright. I wrote something this morning but just...

    alright. I wrote something this morning but just left the house. Latch on immediate command versus failure. Latch for one hour then release. Or if the operator resets the latch. I guess I donít get...
  2. Replies
    10
    Views
    310

    Hmm? So your waiting until the timer value is...

    Hmm? So your waiting until the timer value is greater than the TmDelay then latching. The latch is released when the EqFaultRst is toggled? Where does the 1hr hold then release in your OP come in?...
  3. Replies
    10
    Views
    310

    Ha! Just saw where you said you go it. I was on...

    Ha! Just saw where you said you go it. I was on the computer doing it when you figured it out! LOL
  4. Replies
    10
    Views
    310

    Here is numba's first suggestion. If I'm...

    Here is numba's first suggestion. If I'm understanding. Would have to add a boolean change of state alarm to the alarm point .No this isn't how I would name that. Just making it clear in description...
  5. Our company has done both Metasys and FX for...

    Our company has done both Metasys and FX for years. I've focused on the FX line, and we have about 3 guys that do mostly Metasys. What HVAC pilot says I agree with 100% regarding the FX jace and...
  6. Yeah, income versus cost of living is a thing....

    Yeah, income versus cost of living is a thing. Had some friends who moved outside of DFW recently. They got a lot of house in comparison, but they were a little surprised at the property taxes. Uncle...
  7. Location is a big part of wage in my opinion. The...

    Location is a big part of wage in my opinion. The left and right coasts seem to be at the top. 100k a year is the middle to upper range for a good guy. With 150k being obtainable. This is with full...
  8. Been using export tags since the AX3.6 release....

    Been using export tags since the AX3.6 release. Use them still today
  9. Replies
    12
    Views
    825

    Haven't played with the new APEX controller, an...

    Haven't played with the new APEX controller, an SY1000 but a lot better! I listened to the sales pitch and hear Tridium replacement every time. Yeah Sy1000 isn't a true supervisor but they sure will...
  10. Well if you were an expert on the DX9100 the...

    Well if you were an expert on the DX9100 the FEC/FAC should be a small learning curve
  11. Replies
    47
    Views
    1,570

    LMAO! Strip club ad on the Siemens van!! Pure...

    LMAO! Strip club ad on the Siemens van!! Pure freaking gold right there.


    Sent from my iPhone using Tapatalk
  12. Replies
    12
    Views
    825

    Yeah I never used the sy1000 as the router. Have...

    Yeah I never used the sy1000 as the router. Have an external one setup ready to go. I actually thought about it later and went duh. Could of used it as the router. Wasnít thrilled with the process...
  13. Replies
    8
    Views
    374

    Open with all access to any Tridium hat in town...

    Open with all access to any Tridium hat in town creates problems as well. Maybe be cheaper but a roll of the dice if cheaper doesnít cost more after itís fixed by someone who knows what theyíre...
  14. Replies
    8
    Views
    374

    Licensing the wizard service isn't that much. We...

    Licensing the wizard service isn't that much. We were having some trouble getting distech jaces during COVID. Had a bunch of HW ones we were going to license. Was reasonable from what I recall. I...
  15. Replies
    8
    Views
    374

    Yeah didn't mean rework wouldn't have to happen....

    Yeah didn't mean rework wouldn't have to happen. Lots of ways to think about it, but non of them get you around recreation work that I know of. The statement has a question mark at the end for a...
  16. Replies
    8
    Views
    374

    Do you mean you want graphics created from the...

    Do you mean you want graphics created from the KitPxGraphics palette? Is the pure niagara? If itís a distech station and graphics were created from the DcImages palette? Then yeah some rework will...
  17. Replies
    12
    Views
    825

    Yeah not sure what you mean by downloading the...

    Yeah not sure what you mean by downloading the ECBís to the station? Youíve added them to the database? Theyíre in your NAV tree? Are you working through a Jace ECBOS? Or is this just a station...
  18. Replies
    12
    Views
    825

    Not quite sure what your asking? Are you using...

    Not quite sure what your asking? Are you using the sy1000 as the supervisor of the ECB-103'S? You will have to create your GFX code and then use your EC-NET station to download them. I create a...
  19. Replies
    47
    Views
    1,570

    LMAO!! Now that would be amazing. Those things...

    LMAO!! Now that would be amazing. Those things would be removed the next day.
  20. Replies
    47
    Views
    1,570

    No worries! Can't offend me!

    No worries! Can't offend me!
  21. Replies
    47
    Views
    1,570

    Oh good lord! That went downhill in a hurry. I...

    Oh good lord! That went downhill in a hurry. I started it, so my fault.
  22. Replies
    47
    Views
    1,570

    I love to walk up to those guys, and say you have...

    I love to walk up to those guys, and say you have semen on your truck. Most weren't amused. Now this? They've blown up their competent work force in our area. All good guys have left and are sharking...
  23. Huh everyday ending in Y for me. Sent from...

    Huh everyday ending in Y for me.


    Sent from my iPhone using Tapatalk
  24. Replies
    20
    Views
    1,354

    18 weeks lead time on two VAV controllers coming...

    18 weeks lead time on two VAV controllers coming from our vendor as of yesterday!! LMAO!! What a tire fire.


    Sent from my iPhone using Tapatalk
  25. Yeah mis-spoke there! Was typing before coffee!

    Yeah mis-spoke there! Was typing before coffee!
  26. I started playing with this on my newest laptop,...

    I started playing with this on my newest laptop, and can't get any 64 bit install to work. I know for a 100 percent it's a 64 bit issue. I have all 32 bit version prior to 4.9 installed and licensed...
  27. Replies
    8
    Views
    382

    Yeah Iíve been updating the things since the...

    Yeah Iíve been updating the things since the beginning. Iím at the latest supposed fix. Iíve never had reliability with any WiFi connections. Iíve used external adapters, internal ones, different...
  28. Replies
    8
    Views
    382

    Because the MAP Tool is a heap of steaming Poop....

    Because the MAP Tool is a heap of steaming Poop. I have such disgust and disdain for that overpriced POS I could go on forever. I recently use mine as a router only, and donít even attempt a Wifi...
  29. Had 3 carrier RTU's on a building that we took...

    Had 3 carrier RTU's on a building that we took over. Parker VVT trash at the zone level. Somebody messed with the changeover time if I recall. The things would fire in gas heat, then turn around and...
  30. It's driving me nutty, but I took care of...

    It's driving me nutty, but I took care of building with terminal boxes that had a very similar actuator. This was like 20 years ago so the old brain can't remember what it was? I vaguely remember the...
  31. Yeah years of working on parker VVT in my early...

    Yeah years of working on parker VVT in my early days garnered a lot of dislike for this concept. From a mechanical background what a poor idea! VVT has sent a lot of compressors to the cemetery. Lots...
  32. Replies
    13
    Views
    1,088

    Nobody quit. Just having a hard time finding...

    Nobody quit. Just having a hard time finding qualified guys. Sales went nuts also, which is completely normal here. Weíve got 10 control guys and the boss who still handles a lot field stuff. One of...
  33. Replies
    13
    Views
    1,088

    Were down man power in a bad way right now. I've...

    Were down man power in a bad way right now. I've been over-seeing their work on a very large project that we have them helping on. They know software that is for sure. We will see what the end result...
  34. Replies
    13
    Views
    1,088

    Yeah much rather see it done in MERICA! Were so...

    Yeah much rather see it done in MERICA! Were so ass on fire right now couldn't imagine supporting anyone. In self-preservation mode over here.
  35. Replies
    13
    Views
    1,088

    I think you mean you've sold some control jobs,...

    I think you mean you've sold some control jobs, and question if you or your staff can accomplish the programming needed? Not sure what brand you've sold? But most players have engineering services to...
  36. Replies
    11
    Views
    576

    You can just right click on the BAS license...

    You can just right click on the BAS license service and request license. It should auto update them. I know there was an issue with that function awhile back. He can send you all the license files...
  37. Replies
    6
    Views
    765

    I second ACI have been impressed with them over...

    I second ACI have been impressed with them over the years. Tech support is great also.
  38. Yeah usually do the same thing. Upgrade the home...

    Yeah usually do the same thing. Upgrade the home PC, and play around with it prior to sitting in front of the customer. My work PC will stay Win 10 as long as I can make it.


    Sent from my iPhone...
  39. We've got a couple of guys who've upgraded their...

    We've got a couple of guys who've upgraded their laptops to Win 11. Have no idea why they want to be early adopters. I will kick and scream out of the Win 10 world. That said, if its a customer PC...
  40. Replies
    5
    Views
    582

    Yep seen many of these applications. The JCI PE...

    Yep seen many of these applications. The JCI PE Orion posted used and seen lots of those. Small motor load should be no issue. Bigger motors would be simple to use the PE as pilot duty.
  41. Replies
    9
    Views
    726

    I assume FEC is the same?

    I assume FEC is the same?
  42. Replies
    9
    Views
    726

    Just did it. Changed PCG from N2 to bacnet. Done...

    Just did it. Changed PCG from N2 to bacnet. Done during the download. Don't have PC open right now can't recall exact verbiage just check the right box.
  43. Depends on what your trying points your messing...

    Depends on what your trying points your messing with. Instead of present value you will need to proxy them as relinquish default. 3113 is another trick.
  44. Replies
    14
    Views
    783

    I agree. And when I deleted the points and...

    I agree. And when I deleted the points and re-proxyed them with zero writes times it went away. Also if you don't need writeable points then mapping as non wouldn't hurt as reapers post stated.
  45. Replies
    14
    Views
    783

    Yep this jogs the memory as the fix. Sent...

    Yep this jogs the memory as the fix.


    Sent from my iPhone using Tapatalk
  46. Replies
    14
    Views
    783

    Yes I have seen this exact thing. Itís maddening....

    Yes I have seen this exact thing. Itís maddening. What version Niagara? I wish I recalled my exact steps to fix it. It has been a long time ago in the AX versions, and donít recall what PCG firmware....
  47. I was thinking the same thing when I saw the...

    I was thinking the same thing when I saw the post? Then I thought well maybe he's asking something different with the drop down verbiage? I use the batch editor and edit multiples when doing this.
  48. LOL

    LOL
  49. Well exactly. This is just another time waste for...

    Well exactly. This is just another time waste for us on this job. There is 18 trane units also. The Trane start up, and overall investment in the job to configure things correctly has been down right...
  50. Yeah no carel expert here. Thanks for the info .I...

    Yeah no carel expert here. Thanks for the info .I would say what's in the machine is the mini with no display. Where the Ethernet port is shown on the mini instead of the Ethernet port is the J6 BMS...