Search:

Type: Posts; User: teddy bear

Page 1 of 20 1 2 3 4

Search: Search took 0.17 seconds.

  1. Replies
    31
    Views
    675

    Looks like I can relax a little got a 2nd hand...

    Looks like I can relax a little got a 2nd hand report of "no flooding or major damage for my Cape Coral home that was near the eye.

    Reports lack a physical inspection yet. No power or humidity...
  2. Replies
    31
    Views
    675

    7.00 pm Wed.house was in tact, but the sea water...

    7.00 pm Wed.house was in tact, but the sea water canal was over the sea wall and rising. No report from neighbor since. Sitting on pins and needles with mixed feelings.

    I will keep you posted. ...
  3. Replies
    7
    Views
    225

    Whats your climate? Any concerns about humidity...

    Whats your climate? Any concerns about humidity control?

    Up grade with filtered fresh air to purge indoor pollutants and oxygen renewal?

    Keep us posted.

    Regards Teddy Bear
  4. Do not waste your money on a toy dehumidifier. In...

    Do not waste your money on a toy dehumidifier. In fact at this point, focus on getting the a/c/reheat working. When working properly, no dehumidifier is needed except to reduce operating cost after...
  5. Here is the real test. Ask them for a written...

    Here is the real test. Ask them for a written statement that they will provide a whole house dehumidifier fresh filtered air option like the Santa Fe Ultra if they are unable to maintain <50%RH...
  6. Replies
    31
    Views
    675

    A couple very exciting days!

    The ultimate test of home and systems is watching the results of a direct hit of a strong Hurricane!

    It is new form of entertainment when it is my home in Cape Coral in FL

    I will post a picture...
  7. Replies
    4
    Views
    245

    Are you in high dew area? Location of home? What...

    Are you in high dew area? Location of home? What is the indoor temp/%RH? A/c blower-Auto or On? Fresh air ventilation? Number of occupants?

    Age of home? Check plumbing vent stacks for corrosion...
  8. Replies
    22
    Views
    651

    Original was plain vinegar. I use apple vinegar...

    Original was plain vinegar. I use apple vinegar now. Not sure it makes a difference. I use broiler chickens,6-7 lbs. Fresh if you can get them.

    Regards Teddy Bear
  9. Replies
    22
    Views
    651

    A cup of vinegar, 4 tbs oil, 4tbs salt, 2tbs...

    A cup of vinegar, 4 tbs oil, 4tbs salt, 2tbs black pepper, 1 tbs cyane pepper, sage, garlic, 2 tbs brown sugar or honey, and beat in one egg. marinade 6-8 hours. Brush on the oil and thick part of...
  10. Replies
    11
    Views
    353

    Get a dehumidifier even if Home Depot, 50 pint....

    Get a dehumidifier even if Home Depot, 50 pint. A/c can be off when you are away. Dehu avoid musty or mold.

    Regards Teddy Bear
  11. It takes 45 mins. to dry a cooling coil with the...

    It takes 45 mins. to dry a cooling coil with the blower running. The coil will dry without the fan running in 1.5 hours. You are getting a <1 lb. in the short run you describem, mostly warm the...
  12. Get 70 pint dehumidifier if possible. Maybe next...

    Get 70 pint dehumidifier if possible. Maybe next time, try my suggestion.

    Keep us posted on results.

    Regards Teddy Bear
  13. Make sure your moisture barrier covering the...

    Make sure your moisture barrier covering the earth is in tact. Close the vents to the outside, Then add a ductable dehumdifier to the crawlspace space with 6" fresh air inlet and a 6" duct from...
  14. As you see, technology as changed in the last 12...

    As you see, technology as changed in the last 12 year. The SEERs are up to +20. We now have 2 speed, 5 speed, and VS speed. Complex, expensive, and complicated to fix as they age, but with promise...
  15. Assume we have fan "on" 24/7 or "auto"? What...

    Assume we have fan "on" 24/7 or "auto"?

    What is the target temp/%RH?

    Your cooling coil is producing 50^F dew point air occasionally. Would be better to have a colder cooling coil provided...
  16. The real fix for crawlspace is making sure that...

    The real fix for crawlspace is making sure that there is 9 mil plastic on the earth on the on any exposed earth in the crawl space to stop moisture from evaporating into the space. Next, seal the...
  17. Measurements at the inside return and supply...

    Measurements at the inside return and supply grills will do.

    Teddy Bear
  18. What were the return and supply temps/%RHs during...

    What were the return and supply temps/%RHs during the runs? Fan "auto" or "on"? This will confirm the amount of moisture removed per hour. Do you have the ability to lower the air flow one more...
  19. Replies
    11
    Views
    356

    I would keep the a/cs simple for cost and long...

    I would keep the a/cs simple for cost and long term maintaining. There is a slight advantage with the VS compressors but is complicate and expensive to maintain. During evenings and rainy days the...
  20. Replies
    11
    Views
    852

    I have a home in Cape Coral also. 2,400 sq.ft. I...

    I have a home in Cape Coral also. 2,400 sq.ft. I have a 4 ton a/c which is adequate. I also installed a whole house dehumidifier with 80 cfm of fresh air to get a fresh air change in 4 hours to...
  21. Replies
    2
    Views
    289

    A partially iced coil is an indication of low...

    A partially iced coil is an indication of low refrigerant. Suspect a leak. Do you have fresh air ventilation as part of the dehumidifier?

    Contact the installing contractor for confirmation of...
  22. Before getting to the dehumidifier, suggest that...

    Before getting to the dehumidifier, suggest that you recheck the a/cs setup. During significant sensible cooling loads (50% run cycle), your current a/cs should be able to provide the desired level...
  23. Replies
    80
    Views
    1,784

    Small whole house dehumidifiers remove 3-4 lbs....

    Small whole house dehumidifiers remove 3-4 lbs. per kwh and contribute +-8,000 btus of reheat extend a/c run.
    10 KWHs for typical 40 lbs. per mild season days in a green grass climate and provide...
  24. Replies
    80
    Views
    1,784

    You need the fresh air change in 3-4 hours. You...

    You need the fresh air change in 3-4 hours. You going to here more about the effect on long term health from the health experts as time goes on. This will become of the building codes and medical...
  25. Blower door test estimate the fresh air leakage...

    Blower door test estimate the fresh air leakage during an average winter temperature and 7 mph wind.

    Here is the problem, homes under this condition are typically .1-.3 air change per hour. Yet...
  26. Start with basement/1st floor unit. Your second...

    Start with basement/1st floor unit. Your second floor a/c looks a good setup with the 52^F supply temperature. Also suggest 24/7 dehumidifier fan operation for continuous circulation.

    Thanks for...
  27. Slight negative pressure ok (-.4" WG neg max). ...

    Slight negative pressure ok (-.4" WG neg max).

    If you need to use the 30 pint set %RH +5%RH above the Ultra 70. Also the Broan/Trane are similar to the Santa Fe Ultra.

    Keep us posted.
    ...
  28. Most of moisture in your home is from outside air...

    Most of moisture in your home is from outside air infiltration/ventilation. Your fresh air ventilation is important to purge indoor pollutants and oxygen renewal. Your clothes drier/kitchen...
  29. I understand how the a/c will remove moisture...

    I understand how the a/c will remove moisture from adequate fresh air infiltration/ventilation/occupants during peak cooling loads. A properly setup a/c will will removes 3 lbs. lbs. of moisture per...
  30. Double post sorry. Teddy Bear

    Double post sorry.
    Teddy Bear
  31. What are the temps/RHs outside mid-afternoons/...

    What are the temps/RHs outside mid-afternoons/ basement/1st floor/2nd floor with a/c operating at ??? tstat setting on each a/c? What the a/c supply temps/RHs at the 1st and 2 nd a/cs supply grills?...
  32. Replies
    9
    Views
    452

    [QUOTE=Gigemdh;26274742] Because of the VS on...

    Because of the VS on the upstairs and the addition of VS on the lower unit when replaced, your choice on the connections. Best to cross connect the fresh, filtered air with the two a/cs. The idea...
  33. Adding a whole house dehumidifier to your home...

    Adding a whole house dehumidifier to your home would a simple mild season fix for <50%RH. Keep the surrounding spaces at the desired %RH should fix the bird room.

    During the winter, you may need...
  34. Replies
    9
    Views
    452

    How many sq.ft. for the home and occupants? What...

    How many sq.ft. for the home and occupants? What are typical temp/%RH on 1st/2nd floors? Any concerns about the amount of fresh air circulating during mild seasons of the year?
    Ever monitor the CO2...
  35. Great, you get the benefit of fresh air for your...

    Great, you get the benefit of fresh air for your home. I suggest that you have a fresh air change in 3-4 hours when occupied at a minimum. Like you one of your options, connect the fresh air to the...
  36. Double post.

    Double post.
  37. Replies
    35
    Views
    984

    Suggest reducing amount of return air flowing...

    Suggest reducing amount of return air flowing through the cooling coil to reduce the sensible cooling and increase the latent (moisture) removed by the a/c during significant sensible cooling until...
  38. Replies
    35
    Views
    984

    This gave us good info except the last comment,...

    This gave us good info except the last comment, missing %RH tstat information. Compared to previous information, the fresh air must be off now? I estimated a 500CFM air leak on return, could have...
  39. From your info. Sounds like the dehu is low on...

    From your info. Sounds like the dehu is low on refrigerant, because of ice on coil. Probably a leaking cooling coil. Have you installing contractor check for refrigerant charge and then leak...
  40. Replies
    80
    Views
    1,784

    I think you are jumping the gun. Make sure that...

    I think you are jumping the gun. Make sure that your a/c is setup correctly before adding anything. Confirm that your a/c is setup with the ideal amount of air flow through the cooling coil to...
  41. Replies
    35
    Views
    984

    I was hoping for a/c only running for the...

    I was hoping for a/c only running for the comments on the a/c performance.

    My guess is that you have a major air leakage on the return if your readings are correct. Your a/c air flow should be...
  42. Replies
    35
    Views
    984

    We need return temp/%RH and supply temp/%RH for...

    We need return temp/%RH and supply temp/%RH for the a/c to determine the amount of moisture the a/c is removing. A properly setup a/c running +50% of the time controlling the temperature of the home...
  43. Replies
    80
    Views
    1,784

    The first step is setting up the a/c to supply ...

    The first step is setting up the a/c to supply cold air that is a minimum of 6-7^F dew point lower than the desired dew point in the conditioned space. 75^, 50%RH, a 55^F dew point requires 48^F...
  44. Replies
    80
    Views
    1,784

    A three ton VS a/c with a small whole house...

    A three ton VS a/c with a small whole house dehumidifier would be a good choice that would provide desired temp/%RH 24/7 in a green grass climate 24/7 while providing 3-4 filtered fresh air changes...
  45. Replies
    8
    Views
    597

    Location, current otutside conditions, number of...

    Location, current otutside conditions, number of occupants, and fresh air ventilation?

    Any chance of catching current moisture removed per hour or day?

    Temperature/%RH of the room air and a/c...
  46. Replies
    80
    Views
    1,784

    The fact remains, moisture removal is limited to...

    The fact remains, moisture removal is limited to the sensible cooling load. A ton of sensible/latent cooling is limited to 3 lbs. per hour. Greenspeed limits over-cooling to -3^F below the t-stat...
  47. Adding exhaust to the attic may put a negative...

    Adding exhaust to the attic may put a negative pressure on the attic which sucks more damp outside air and cool air from the house. Insulation on cold supply ducts sweat when the exterior temperature...
  48. I have a home in 2,500 SW FL FT Myers/Cape Coral...

    I have a home in 2,500 SW FL FT Myers/Cape Coral area. Eleven year old home with 4 ton a/c and electric heat. Use heat 1-3 X year. I added a 100 pint Santa Fe Ultra dehumidifier with fresh,...
  49. Replies
    80
    Views
    1,784

    Everybody, relax a little. We are here to...

    Everybody, relax a little.

    We are here to help everyone!

    During peak sensible cooling loads, a properly setup a/c should maintain <5%RH. It is a matter of adjusting the air flow through the...
  50. Replies
    24
    Views
    3,620

    Keeping the indoor temperatures below outdoor dew...

    Keeping the indoor temperatures below outdoor dew points causes condensation in the exterior surfaces that cold on the inside and exposed to the outdoor dew points. Vapor barriers and warmer indoor...
Results 1 to 50 of 1000