    Could definetley be, I've had them go bad on...

    Could definetley be, I've had them go bad on Vulcan convection units before, same problem where it wasn't as hot as it should be.
  2. Replies
    46
    Views
    1,261

    Very true, I agree with that.

    Very true, I agree with that.
  3. This is the model. LACA-032E-TAC-800 Looks...

    This is the model.

    LACA-032E-TAC-800

    Looks similar but I don't think the models similar, it's quite large.
  4. That is correct, according to copeland, 225*F is...

    That is correct, according to copeland, 225*F is the MAX MAX MAX discharge temp on the discharge line.
  5. Check the discharge temps, check the suction...

    Check the discharge temps, check the suction temps, SH and that'll tell you if it's too hot.

    I know I have a similar one for a freezer but it has a fan on it and is water cooled.
  6. I would think if overheating was a problem, there...

    I would think if overheating was a problem, there would be more indicators than that, I don't see any discoloration to where the oil might have been baked on.

    Is the oil is sticky or tacky, I...
  7. Replies
    46
    Views
    1,261

    I do agree with the pay being more potentially...

    I do agree with the pay being more potentially attracting more people.

    And it is true, unfortunately a lot of the youngin's are starting out gaming in a young age where they naturally lean more...
  8. If all the other comps are the same type, you...

    If all the other comps are the same type, you should check those units for inlet SH to the comp and see how they run, could've been JUST that compressor having a problem or a bigger problem in...
  9. Important you keep an eye on it, a drop in...

    Important you keep an eye on it, a drop in suction pressure affects the compression ratio significantly and can rapidly cause the compressor to overwork itself.
  10. Attaboy.

    Attaboy.
  11. Makes sense. Fully understand your position....

    Makes sense.

    Fully understand your position. The key is just to realize and understand that something killed the compressor you are pulling out and spending 10-20 minutes taking the head off to...
  12. Hmm. Got pictures? How are the valves shot?...

    Hmm.

    Got pictures?

    How are the valves shot? Pistons look messed up?

    any discoloration of the piston seats, rings or anything? Was the oil sticky, tacky and full of metal?

    Details man,...
  13. What's wrong with the old one?

    What's wrong with the old one?
  14. Replies
    46
    Views
    1,261

    Considering I learned this trade without going to...

    Considering I learned this trade without going to school and mostly without someone else teaching me until I was quite a ways into it AS well as being of the "newer" generation, I can say that the...
  15. Replies
    45
    Views
    1,384

    There's a bit of a difference there. If a cop...

    There's a bit of a difference there. If a cop asked me straight up if I was speeding, I wouldn't lie to him.

    I see your point though, I'm just saying, if I KNOW that the compressor is using a...
  16. Replies
    45
    Views
    1,384

    I agree, if I arrived to the job and saw it was...

    I agree, if I arrived to the job and saw it was different refrigerant than what was listed for the comp I wouldn't lie to the manufacturer, I would tell them and see if they would still honor the...
  17. Replies
    45
    Views
    1,384

    Yeah, I'm not convinced. 15-30 minutes is not...

    Yeah, I'm not convinced.

    15-30 minutes is not a very long time, much less without an actual start and end reading, I can't tell you if it was good or bad.

    Not pressure testing is cheap and...
  18. Replies
    45
    Views
    1,384

    Okay, that makes more sense but still, A...

    Okay, that makes more sense but still,

    A vacuum is not a good way to test for leaks, it could be a small leak and he could be seeing a micron rise on his gauges and blamed it on something else,...
  19. Replies
    45
    Views
    1,384

    I mean, I wouldn't lie to the manufacturer and I...

    I mean, I wouldn't lie to the manufacturer and I would personally feel bad about not telling them that something else was in it, if I knew about it.

    They might check the oil in the compressor and...
  20. Replies
    45
    Views
    1,384

    Good point, that probably voided your warranty...

    Good point, that probably voided your warranty right there.
  21. Replies
    15
    Views
    26,529

    Better late than never.

    Better late than never.
  22. Replies
    45
    Views
    1,384

    Poodle Head knows much more about this than I do,...

    Poodle Head knows much more about this than I do, in general, lol.

    But I would also be wary of having refrigerant with one oil and a comp with another, there's a reason they aren't the same and I...
  23. It shouldn't be stably dropping even if it has...

    It shouldn't be stably dropping even if it has refrigerant in it.

    If anything, it would go down, then up, then down, etc.
  24. Replies
    5
    Views
    373

    I had a nightmare one where the filtration bin...

    I had a nightmare one where the filtration bin had tubing that was clogged, I had to drill a hole into the tube and through the carbon blocking it, then weld it back together.

    if it's just oil,...
  25. Replies
    6
    Views
    361

    Most compressors are designed for a specific...

    Most compressors are designed for a specific application, BTU rating and volumetric flow as well as power and type of oil and refrigerant.

    You can't just get any "2 Ton Compressor, it won't work....
  26. 80% of the load is the max rating of the breaker,...

    80% of the load is the max rating of the breaker, 16 amps would the max allowed load on a 20 A breaker.

    as far as I know, so I'd say you're good IF the unit was rated for 15 amps.

    But it's MAX...
  27. Replies
    33
    Views
    799

    When is the next tech coming out?

    When is the next tech coming out?
  28. Replies
    17
    Views
    611

    Yeah, it all depends on the part you are trying...

    Yeah, it all depends on the part you are trying to make.

    Some things are not feasible to 3D print, others definetley are. Unless you drop a couple of grand on a printer, you won't be able to...
  29. Replies
    33
    Views
    799

    If it runs, I doubt it's the start cap but it...

    If it runs, I doubt it's the start cap but it could be other start components.

    When the compressor starts the start capacitor gives it what is essentially a kick start and gets it going, there is...
  30. Replies
    17
    Views
    611

    Plenty of food safe filaments and there's ways to...

    Plenty of food safe filaments and there's ways to make them food safe after the fact if you are worried about it, I find that nylon gives the cleanest seams between the layers where another common...
  31. Replies
    17
    Views
    611

    True, doing writing or logo in 3D is really easy...

    True, doing writing or logo in 3D is really easy though.

    Making a model which is "solid" and where all intersecting geometry is done properly is much more difficult, took me a while to get the...
  32. Replies
    33
    Views
    799

    Yeah, sounds like a safety going out. ...

    Yeah, sounds like a safety going out.

    Bypassing a hard start makes no sense, replacing one to see if the old one was bad I could understand, the compressor won't start without a hard start or...
  33. Replies
    5
    Views
    239

    I find the chefs normally have a pretty good idea...

    I find the chefs normally have a pretty good idea if something is wrong, at least where I work.

    As for the sound, It could be the spark module as mentioned above, otherwise I've had issues with...
  34. Replies
    33
    Views
    799

    The tech bypassed the start cap? For what?

    The tech bypassed the start cap? For what?
  35. Replies
    33
    Views
    799

    :angel:

    :angel:
  36. Replies
    33
    Views
    799

    If the compressor didn't run then there's no way...

    If the compressor didn't run then there's no way he could verify that. Getting pressures and seeing if they are good or bad takes at least a couple of minutes of run time.

    He may have looked at...
  37. Replies
    33
    Views
    799

    Okay, I can't see the video but that's fine. ...

    Okay, I can't see the video but that's fine.

    Who said the pressures were "OK"?
  38. Replies
    17
    Views
    611

    I can tell you from experience and having a 3D...

    I can tell you from experience and having a 3D printer that they definetley come in handy.

    I tried making barbed and threaded fittings today, like 1/8" NPT with a 1/4" barb on the other end. it's...
  39. Replies
    33
    Views
    799

    IF the compressor actually runs, which it would...

    IF the compressor actually runs, which it would have to for pressures to be "OK" then the compressor is probably not the issue.

    there's normally an internal safety in the compressor that protects...
  40. Replies
    50
    Views
    968

    Okay, that's fine. I don't really care for...

    Okay, that's fine.

    I don't really care for the argument.

    If you have a question, ask me, I will answer it.
  41. Replies
    50
    Views
    968

    What you do on your own time with your own tools...

    What you do on your own time with your own tools on your own property is up to you, as far as I'm concerned you have to be licensed in order to hook up gauges, but that's not why I'm here.

    Don't...
  42. Replies
    8
    Views
    440

    What makes you think that's the culprit? ...

    What makes you think that's the culprit?

    Because it's visible?
  43. Replies
    50
    Views
    968

    I think I might be late to the party but here's...

    I think I might be late to the party but here's my suggestion.

    If the techs get upset from asking what's wrong, just make sure you don't come off as pushy, when we are troubleshooting our mind is...
  44. What happened? Did it get fixed? Was it the...

    What happened? Did it get fixed?

    Was it the Nest?
  45. Replies
    42
    Views
    2,256

    Sure, I can give you the phone number or email of...

    Sure, I can give you the phone number or email of my Rep, perhaps he can help you get set up faster?
  46. Replies
    42
    Views
    2,256

    Gleng, Did you ever get an account set up? I...

    Gleng,

    Did you ever get an account set up? I get really good discounts ,much better than I do with Heritage.
  47. Replies
    42
    Views
    2,256

    Lol. I think Parts Town bought Heritage, Parts...

    Lol.

    I think Parts Town bought Heritage, Parts town seemed to be getting bigger than Heritage.
  48. Unprofessional. I would have at least...

    Unprofessional.

    I would have at least electrical taped it but pointed the wire nut up to keep rain from getting in it.

    Just common courtesy.
  49. Replies
    42
    Views
    2,256

    Do you have an account with them or just online...

    Do you have an account with them or just online pricing?
  50. Replies
    42
    Views
    2,256

    Very true. I get better pricing from Parts...

    Very true.