Search:

Type: Posts; User: heatingelement

Page 1 of 12 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    0
    Views
    1,178

    Not a happy customer of YJ

    I bought the P51-870 digitals about since months ago. First set leaked right out the box. Sent me another. I used them maybe 15 times total. Now the second set is leaking from the sight glass! What...
  2. I'd suggest learning more of the basics before...

    I'd suggest learning more of the basics before trying to understand how it changes things. Learn line temperatures of the system, pressures of refrigerant, saturation, metering devices, what...
  3. Open the registers!

    Open the registers!
  4. Replies
    2
    Views
    349

    That sheet says It was 62 degrees outside. I'm...

    That sheet says It was 62 degrees outside. I'm guessing inside was under 70 degrees? I didn't see set bulb or dry bulb indoor readings unless I missed it. System seem to perform Ok? You can't really...
  5. Seal them up. I usually plug them with plastic...

    Seal them up. I usually plug them with plastic red plugs for future.
  6. Replies
    9
    Views
    1,078

    I have a 16 year old and this was spot on!

    I have a 16 year old and this was spot on!
  7. Replies
    5
    Views
    880

    Check your subcooling, that should tell you if...

    Check your subcooling, that should tell you if you have enough refrigerant. Sometimes you can hear it flashing off at the txv.
  8. Replies
    5
    Views
    826

    Veto bags are nice. Very well built. Carry the...

    Veto bags are nice. Very well built. Carry the best warranty program as long as you purchased through a certified dealer only. I picked up the mini mb2 that I use for diagnostics and pull the large...
  9. Replies
    17
    Views
    1,617

    You must have stock in fielpiece...

    You must have stock in fielpiece...
  10. Replies
    17
    Views
    1,617

    Good to know. Thanks. Learn something here just...

    Good to know. Thanks. Learn something here just about everyday. Appreciate it everyone!
  11. Replies
    105
    Views
    5,407

    Replaced the Piston? Was it the wrong size? I've...

    Replaced the Piston? Was it the wrong size? I've never seen a failed piston. What was wrong with it?
  12. Replies
    17
    Views
    1,617

    I have not seen this formula, is this actually...

    I have not seen this formula, is this actually uses to determine what your superheat should be? I usually go off the chart per manufacture. Assuming this is only for a fixed orifice?
  13. Replies
    15
    Views
    7,108

    Is the outdoor unit communicating also? If so...

    Is the outdoor unit communicating also? If so hopefully it has a transformer as well. I've seen loose low voltage wires cause communication issues on these. In my few times I have used tech support...
  14. Replies
    33
    Views
    1,549

    You'll need to get your lost count up and apply...

    You'll need to get your lost count up and apply for pro status. You're likely not going to get that info on the open forum. If suggest studying symbols and wiring diagram/schematics. Exam the clear...
  15. Replies
    3
    Views
    628

    Sounds like a restriction and your on the right...

    Sounds like a restriction and your on the right track for the txv. I usually check the filter drier and make sure that's not the issue as well.
  16. If your system has had a leak in it for awhile,...

    If your system has had a leak in it for awhile, freezing up all the time and such, that means you probably haven't had the proper refrigerant (cooling) back to the compressor which can damage it long...
  17. Replies
    4
    Views
    420

    I installed a couple of these and I noticed more...

    I installed a couple of these and I noticed more options in the installer setup after you set it up the first time. I had to change settings after the first setup and I noticed several options that...
  18. Replies
    47
    Views
    2,059

    350 to 400 cfm per ton depending on your area and...

    350 to 400 cfm per ton depending on your area and humidity. Setback is when you allow the system to "catch up" from turning it down at night or away. Rather than setting it and leaving it, works...
  19. They told me when I walked to the counter after...

    They told me when I walked to the counter after the test.
  20. Replies
    18
    Views
    1,450

    Don't see that model anymore. Darn

    Don't see that model anymore. Darn
  21. Replies
    18
    Views
    1,450

    That is awesome. I'll have to check those out.

    That is awesome. I'll have to check those out.
  22. Replies
    18
    Views
    1,450

    Mini meter?

    Mini meter?
  23. Replies
    18
    Views
    1,450

    I have went through 3 fieldpeice clamp meters in...

    I have went through 3 fieldpeice clamp meters in 3 years. All in the first year. Replaced it with uei and it's going on 2 years no issues. I use my fluke for verifying shorted compressors and if I...
  24. Replies
    5
    Views
    1,494

    I picked up the new YJ digital touch screen...

    I picked up the new YJ digital touch screen manifold. I am happy with them.
  25. Replies
    9
    Views
    775

    Hide was 80 degrees, doesn't sound like it was...

    Hide was 80 degrees, doesn't sound like it was working fine unless you keep it st 80...
  26. Replies
    42
    Views
    16,571

    YJ sent a new replacement and I sent the old one...

    YJ sent a new replacement and I sent the old one back. Had a chance to test it out. Evacuation works great, holds with no raise. Also got to test out the pressure test feature. Works very well. I...
  27. Replies
    20
    Views
    1,024

    Usually airflow is set to a speed for a reason....

    Usually airflow is set to a speed for a reason. You could trip the heat pump in heat mode and possibly cause liquid to hit the compressor if you're not sure what you're doing.
  28. Replies
    2
    Views
    1,076

    This may or may not apply, but if I remember...

    This may or may not apply, but if I remember correctly on a none heat pump application (AC), there's a jumper needed on the zone board for HP switch. Mayne have them reread the installation manual...
  29. Replies
    13
    Views
    886

    What is the issue exactly? It sounds to me like...

    What is the issue exactly? It sounds to me like the a.c. not cooling?
  30. Replies
    19
    Views
    1,304

    HE needs to be willing to take time out of his...

    HE needs to be willing to take time out of his day to day life and want to learn. Read, classes, take notes, apply himself. Otherwise you're wasting time.
  31. Strange they did not offer a 410a option. I don't...

    Strange they did not offer a 410a option. I don't think either provided ALL options for you. Maybe im wrong but i think one should be able to pull a furnace and put it back without breaking a bunch...
  32. Replies
    4
    Views
    483

    What was the supply and return temps and what...

    What was the supply and return temps and what kind of unit is this?
  33. Replies
    20
    Views
    1,667

    Raise your head pressure. Over charges the...

    Raise your head pressure. Over charges the system, if it's a heat pump it could trip HP when mild out. I would think it would also change your condensing temperature which lowers efficiency.. but not...
  34. Replies
    28
    Views
    1,900

    I've never heard of such. I've never recovered to...

    I've never heard of such. I've never recovered to recharge unless It's a heat pump and cold outside or doing an r22/nitro leak search.
  35. That doesn't sound fun.

    That doesn't sound fun.
  36. How's the air filter?

    How's the air filter?
  37. I believe those older caps use PCBs.. I could be...

    I believe those older caps use PCBs.. I could be wrong. I'm sure someone will correct me if I am.
  38. I just looked up icecold. First time I've heard...

    I just looked up icecold. First time I've heard of it. People will buy anything huh lol.
  39. We promote nest, unfortunately :( So many of...

    We promote nest, unfortunately :(
    So many of our new techs are selling it, it's scary. I told them in not going to be a part of it nor stock one on my van.
  40. Titan HD mainly, they are made in US. Sometimes...

    Titan HD mainly, they are made in US. Sometimes the turbo mini, 200 or 200X. Haven't had many issues that I'm aware of.
  41. Replies
    42
    Views
    16,571

    Not sure exactly. Wouldn't hold microns under a...

    Not sure exactly. Wouldn't hold microns under a vacuum. Thought it was the system at first but I swapped manifolds and used the same micron gauge, no issues.
  42. Replies
    42
    Views
    16,571

    Issue with gauge or manifold not holding microns....

    Issue with gauge or manifold not holding microns. After testing it with different micron gauges, manifold set and hoses, I determined the new set was leaking someplace.

    I tried to go through...
  43. Replies
    19
    Views
    1,030

    We need to make sure... This is not a nest...

    We need to make sure... This is not a nest thermostat is it?
  44. Replies
    19
    Views
    1,030

    If it's cycling on and off frequently it could be...

    If it's cycling on and off frequently it could be due to being oversized for the home. This can also cause it not to remove as much humidity as it should during the longer on cycles. You should...
  45. Replies
    9
    Views
    607

    Any chance I get, I show the customer.

    Any chance I get, I show the customer.
  46. Replies
    9
    Views
    607

    You could drill a hole in it but not a crack....

    You could drill a hole in it but not a crack. There's likely a darker shade where the crack is, along with rust and stuff otjers mentioned.
  47. Replies
    42
    Views
    16,571

    1 week into these, used them twice and they leak....

    1 week into these, used them twice and they leak. yellow jacket won't send me a replacement. Seriously $500... never buying YJ products again.
  48. Replies
    17
    Views
    1,707

    I'd carry but don't think it's allowed per emp...

    I'd carry but don't think it's allowed per emp handbook
  49. Thread: Pogs???

    by heatingelement
    Replies
    6
    Views
    576

    Slammer!

    Slammer!
  50. Replies
    17
    Views
    1,707

    Got it a few days ago. First time I put It on my...

    Got it a few days ago. First time I put It on my 3 year old said "that's for a grandma" haha!

    It fits my 9mm shield ok. The zipper barely touches the back part of the slide. Fits my S7 Samsung...
Results 1 to 50 of 596
Page 1 of 12 1 2 3 4