  1. Its probably scrambled. Try calling Danfoss,...

    Its probably scrambled.

    Try calling Danfoss, but My money is betting your gonna be replacing a drive in the near future.




    Sent from my iPhone using Tapatalk
  2. Replies
    21
    Views
    751

    What do you clear condensate lines with? And...

    What do you clear condensate lines with?

    And nitro is cheap.

    Like 35 for 80 CF refill I think


    Sent from my iPhone using Tapatalk
  3. Replies
    14
    Views
    578

    Whats that goober on the pipe at the base of the...

    Whats that goober on the pipe at the base of the CoreMax ports about?


    Sent from my iPhone using Tapatalk
  4. Replies
    21
    Views
    751

    Long Hoses for Nitrogen

    I just use 1/4 x 1/4 flare couplings and multiple normal hose.

    Not really for this, but for working on a unit in a ceiling for example, I can have the recovery unit and such safely on the ground....
  5. Collapsed evaporator tubes - anyone seen this before??

    The man said he removed the discharge piping to look inside the bundle.

    That and the copper and steel is way too clean to be the waterside.

    I realize the word discharge does not really go hand...
  6. Could boiling refrigerant be violent enough to...

    Could boiling refrigerant be violent enough to cause that?

    Like I said above, I believe water to be inside the tubes, and refrigerant to be in the shell.

    With the machine having been offline...
  7. Im not certain, cause I dont know what machine he...

    Im not certain, cause I dont know what machine he is working on, but it sounds to me like the water is in the tubes, and refrigerant is in the shell.

    You dont typically eddy current test the tubes...
  8. With steam? When steam is contained inside a...

    With steam?

    When steam is contained inside a vessel or pipe, or radiator, when it cools, the water vapors volume decreases significantly. Steam to water volume ratio is roughly 1600 to 1.



    ...
  9. The shell. Heres what water hammer damage...

    The shell.

    Heres what water hammer damage looks like, at least when steam is involved.

    https://uploads.tapatalk-cdn.com/20190913/67d3ff1c4c3bdfd3b2eb81a52de4fb0a.jpg


    Sent from my iPhone...
  10. Replies
    10
    Views
    368

    They make ones that modulate, not sure if that...

    They make ones that modulate, not sure if that one does or not.


    Sent from my iPhone using Tapatalk
  11. Thats a good theory. Most heat exchangers of this...

    Thats a good theory. Most heat exchangers of this design I see are rated to 300 psi or better, shell and tube side.


    Sent from my iPhone using Tapatalk
  12. Replies
    14
    Views
    578

    JB makes the valves. It is called a core max....

    JB makes the valves.

    It is called a core max. You can probably get a pack of 20 for 60 bucks or less.

    I would not bother with the removal tool.

    Remove the gas and replace the core. It...
  13. Collapsed evaporator tubes - anyone seen this before??

    Cause, energy is lazy. It was easier to crush the tubes then steel support plate. That and it does appear on second look that the support plate is contouring to the pinch down of the tubes.


    Sent...
  14. Replies
    13
    Views
    393

    I assume a crane will be part of the job, no? ...

    I assume a crane will be part of the job, no?

    That would be the safest way.




    Sent from my iPhone using Tapatalk
  15. Replies
    13
    Views
    393

    Safety margin is typically 200 percent of rating....

    Safety margin is typically 200 percent of rating. So fully extended you might be okay with the as designed hoist.

    Add some jethro engineered extension and your not even in the ball park capacity...
  16. Replies
    8
    Views
    402

    Yes it can be. Sent from my iPhone...

    Yes it can be.




    Sent from my iPhone using Tapatalk
  17. Cool. That energy saver mode sounds idiotic. ...

    Cool.

    That energy saver mode sounds idiotic.


    Sent from my iPhone using Tapatalk
  18. Replies
    24
    Views
    687

    Even if the equation is accurate, many times, the...

    Even if the equation is accurate, many times, the listed FLA on the unit for a given motor is not accurate to the actual motor used.

    Manufacturers will use motors that they have access to at a...
  19. Replies
    17
    Views
    905

    Its hard plastic Sent from my iPhone using...

    Its hard plastic


    Sent from my iPhone using Tapatalk
  20. Yep. OP you have com to ch1 TT from the...

    Yep.

    OP you have com to ch1

    TT from the control needs to go to the R and CH1 on the boiler.

    Im not possitive about the need or lack of need to have a contact closure for “heat demand” on...
  21. Is anything landed on terminals 7-8 that say...

    Is anything landed on terminals 7-8 that say “heat demand” ?


    Sent from my iPhone using Tapatalk
  22. Replies
    5
    Views
    409

    I do think they are probably doing as you say and...

    I do think they are probably doing as you say and justifying their purpose.

    But as far as conflict, I dont really think so.

    Most balance contractors also do commission work.

    It would be a...
  23. Replies
    13
    Views
    804

    I assume the tenant is a restaurant. Restaurants...

    I assume the tenant is a restaurant. Restaurants are amazingly cheap when it comes to repairs of this nature.

    I bet if the tech would have asked for permission to make the temporary repair, they...
  24. Do you have access to a megger? Sent from my...

    Do you have access to a megger?


    Sent from my iPhone using Tapatalk
  25. Replies
    5
    Views
    794

    Im not sure. But being lennox, Id assume its...

    Im not sure. But being lennox, Id assume its proprietary communications of some kind.




    Sent from my iPhone using Tapatalk
  26. Replies
    4
    Views
    368

    Almost sounds like the 1.5 ton condenser is the...

    Almost sounds like the 1.5 ton condenser is the only correct match, or the closest.


    Sent from my iPhone using Tapatalk
  27. Replies
    13
    Views
    584

    I have the m12 version and its a sweet little...

    I have the m12 version and its a sweet little light. Clamp and magnet. Works well.


    Sent from my iPhone using Tapatalk
  28. Replies
    5
    Views
    794

    You can get a converter from 0-10 to pwm, or just...

    You can get a converter from 0-10 to pwm, or just get a control with a pwm output.




    Sent from my iPhone using Tapatalk
  29. Replies
    21
    Views
    960

    Is this a pump down system. Many Lieberts are,...

    Is this a pump down system.

    Many Lieberts are, and therefore have solenoids on the liquid lines.




    Sent from my iPhone using Tapatalk
  30. Always default to the condensers charging...

    Always default to the condensers charging recommendations for the application.




    Sent from my iPhone using Tapatalk
  31. Just go with what the outdoor unit nameplate...

    Just go with what the outdoor unit nameplate shows as a factory charge. Its an irrelevant question. You being in Cali, they are probably getting ready to implement a refrigerant amount surcharge, or...
  32. Replies
    4
    Views
    275

    Dan, Just remove the entire motor and blade set...

    Dan,
    Just remove the entire motor and blade set and bring it to Dreisilker Electric.

    They will match it up for you.


    Sent from my iPhone using Tapatalk
  33. Replies
    9
    Views
    355

    I have a hard time a puller wont remove it. ...

    I have a hard time a puller wont remove it.

    Ive never met a resi blower that cant be dismantled with a puller.

    The obvious would be a set screw you missed.

    I had one that had 2 allen set...
  34. Replies
    7
    Views
    316

    Assuming you have the correct amplifier card for...

    Assuming you have the correct amplifier card for flame rectification, the problem is not the control itself.

    Now, whether or not the control is 100 percent correct for the application, that I...
  35. Replies
    3
    Views
    222

    No need to apologize, I just wanted you to have...

    No need to apologize, I just wanted you to have the best chance for a meaningful answer to your questions.


    Sent from my iPhone using Tapatalk
  36. Replies
    7
    Views
    316

    The flame rod needs to be one that fits the...

    The flame rod needs to be one that fits the burner, which I assume would be the eclipse.

    The original control, and the new control sound to me to be having the same problem. Flame failure,...
  37. Replies
    3
    Views
    222

    Your gonna want to have this moved, or repost in...

    Your gonna want to have this moved, or repost in the controls forum.


    Sent from my iPhone using Tapatalk
  38. Replies
    5
    Views
    1,683

    Fuji, will have to look into that. I bought...

    Fuji, will have to look into that. I bought something, not sure what at this moment, but I dont trust its readings.


    Sent from my iPhone using Tapatalk
  39. Replies
    27
    Views
    956

    Oh, that far left “valve” is not a valve, its a...

    Oh, that far left “valve” is not a valve, its a thermometer in a well.

    Now that’s ingenious.


    Sent from my iPhone using Tapatalk
  40. Thread: Reznor VRF

    by heatingman
    Replies
    7
    Views
    332

    Ive never been a fan of the copeland digital...

    Ive never been a fan of the copeland digital scrolls.




    Sent from my iPhone using Tapatalk
  41. Thread: Reznor VRF

    by heatingman
    Replies
    7
    Views
    332

    Im intrigued that VRF is 75% of your work. I...

    Im intrigued that VRF is 75% of your work. I think thats kinda cool. Always good to have a niche.


    Sent from my iPhone using Tapatalk
  42. Replies
    47
    Views
    1,218

    208/230 nameplate 230/460 motor

    You need to slow down the blower.

    Carrier wants this done via the pulleys, as they expect high speed to run 60 hrz.

    You can change the programmed speeds aswell, but that requires an interface...
  43. Replies
    27
    Views
    956

    Wouldn’t the other valve on the left be...

    Wouldn’t the other valve on the left be sufficient?


    Sent from my iPhone using Tapatalk
  44. Replies
    27
    Views
    956

    Whats the far left valve for? Sent from my...

    Whats the far left valve for?


    Sent from my iPhone using Tapatalk
  45. Replies
    15
    Views
    790

    What are you good at? Start with that. What are...

    What are you good at? Start with that. What are you interested in? Plan for that.

    Take whatever you can get. Just don’t sell yourself short. Its better to not do a job, then do a job that will...
  46. Is he trying to do automatic or manual change...

    Is he trying to do automatic or manual change over?

    I’ll check my stat at home when I get back this evening, but I think I may be able to do that with manual change over on it. Im pretty sure mine...
  47. Im not following what your asking. Are you...

    Im not following what your asking.

    Are you talking about a deadband between heating and cooling set points, or the differential to start the unit/stop the unit?


    Sent from my iPhone using...
  48. Replies
    11
    Views
    555

    You need to charge by the units charging chart,...

    You need to charge by the units charging chart, or target superheat for the operating conditions.

    A smaller suction line if anything will reduce suction pressure, but on a short lineset, not by...
  49. Replies
    32
    Views
    1,189

    Ive done plenty. Sent from my iPhone using...

    Ive done plenty.


    Sent from my iPhone using Tapatalk
  50. Replies
    7
    Views
    315

    I believe 2 of the relays PHM mentioned would do...

    I believe 2 of the relays PHM mentioned would do the trick.

    It would be a cool project for your friend and his son to figure out the wiring together.

    I could draw something out, but I think...