  1. Replies
    5
    Views
    554

    just called fujistsu tech support ,they said the...

    just called fujistsu tech support ,they said the minimum pipe ran is for noise, but this unit will be cooling/heating a commercial space so noise wouldn't be a problem for them, I dont believe it...
  2. Replies
    5
    Views
    554

    just called fujistsu tech support ,they said the...

    just called fujistsu tech support ,they said the minimum pipe ran is for noise, but this unit will be cooling/heating a commercial space so noise wouldn't be a problem for them I dont believe it will...
  3. Replies
    5
    Views
    554

    yes 16' minimum is the pipe run for 36k btu units...

    yes 16' minimum is the pipe run for 36k btu units between indoor & outdoor, its 10' minimum for fujitisu 12k -24k btu units according to brochure.I got to comfortable running pipe for smaller size...
  4. Replies
    5
    Views
    554

    36k fujitsu lineset run

    Hello techs , I installed a 36k fujistu split unit , but ran the refrigeration piping about 11ft to outdoor unit , I guess I didnt read the instructions on this install, which is minimum pipe length...
  5. Replies
    2
    Views
    510

    ok thanks for the feedback Sent from my...

    ok thanks for the feedback

    Sent from my SM-G950U using Tapatalk
  6. Replies
    2
    Views
    510

    condenstate pump selection

    hello techs,I want to install a condenstate pump for a 36k btu wall unit , I would like to know which pump would be best option to choose ,Refco gobi 2 or Aspen in-unit 83939 ,any experience using...
  7. Replies
    24
    Views
    1,958

    I have the same YJ 60278 , works great are you...

    I have the same YJ 60278 , works great are you using a torch wrench or your adjustable ranch to tighten the flare nut?

    Sent from my SM-G950U using Tapatalk
  8. Replies
    7
    Views
    635

    make since what your saying , I guess plumber...

    make since what your saying , I guess plumber would need to be involved, when connecting to bldg side of drain,thanks

    Sent from my SM-G950U using Tapatalk
  9. Replies
    7
    Views
    635

    ok, so it's best to have a plumber look in to...

    ok, so it's best to have a plumber look in to it,thanks

    Sent from my SM-G950U using Tapatalk
  10. Replies
    7
    Views
    635

    tapping into drain lines

    hello techs , I have seen installation jobs where the crew taped there condensate drain line into bathroom/ kitchen sink drain,near the trap area or to the bldg cast iron drain pipe,looks very...
  11. Replies
    24
    Views
    1,958

    I have the rectoseal flaring set ,I will be using...

    I have the rectoseal flaring set ,I will be using it for the first time, it should work, thanks

    Sent from my SM-G950U using Tapatalk
  12. Replies
    24
    Views
    1,958

    I will check it out & thanks for info Sent...

    I will check it out & thanks for info

    Sent from my SM-G950U using Tapatalk
  13. Replies
    24
    Views
    1,958

    ok, thanks Sent from my SM-G950U using...

    ok, thanks

    Sent from my SM-G950U using Tapatalk
  14. Replies
    24
    Views
    1,958

    flaring tool option

    hello techs , is any one using the pro-fit flaring tool kit from rectorseal ,I find it the convenience way to make flare fitting using your drill machine ,but not sure how reliable it is & not...
  15. Replies
    2
    Views
    587

    yes 1 outdoor 2 indoors for 1000 sq ft includes...

    yes 1 outdoor 2 indoors for 1000 sq ft includes all interior walls , average workers would be 2-3 ppl ,theres also 2 beverage coolers in the store , I would go with different brand then fujitsu, if...
  16. Replies
    2
    Views
    587

    need to size ac system

    hello techs ,i would like to size the correct size mini split unit for a retail store it's aprox 1000 sq.ft with a 10ft ceiling height, the store owner wants me to install 1 wall unit first, in the...
  17. Replies
    34
    Views
    1,848

    [emoji106] Sent from my SM-G950U using Tapatalk

    [emoji106]

    Sent from my SM-G950U using Tapatalk
  18. Replies
    34
    Views
    1,848

    I won't be using the leak seal & never did due...

    I won't be using the leak seal & never did due to different opinions,I rather go the old school way & that's find the leak & fix the leak ,thanks for sharing.

    Sent from my SM-G950U using Tapatalk
  19. Replies
    34
    Views
    1,848

    I would like to follow the same procedure as you...

    I would like to follow the same procedure as you mentioned,but am working with a fujistu unit & it wont let me leave the leaking circuit disconnected for to long or it will go into error code,...
  20. Replies
    34
    Views
    1,848

    I would stay at 450- 500 max Sent from my...

    I would stay at 450- 500 max

    Sent from my SM-G950U using Tapatalk
  21. Replies
    34
    Views
    1,848

    it's a 410A fujistu unit. Sent from my...

    it's a 410A fujistu unit.

    Sent from my SM-G950U using Tapatalk
  22. Replies
    34
    Views
    1,848

    no,the job was done by someone else years ago,for...

    no,the job was done by someone else years ago,for me to find the leak my plan is to close the service valves at the condensing unit, & isolate the 3 zones & then pressure to 500psi with nitro, to...
  23. Replies
    34
    Views
    1,848

    [emoji106] Sent from my SM-G950U using Tapatalk

    [emoji106]

    Sent from my SM-G950U using Tapatalk
  24. Replies
    34
    Views
    1,848

    they sell the flare inserts online,I never used...

    they sell the flare inserts online,I never used them before, in my opinion i dont like flare connections. If I can braze i would braze & never worry about it leaking,thank you for your...
  25. Replies
    34
    Views
    1,848

    I did try to pull the unit out to get to the...

    I did try to pull the unit out to get to the flare connections but no luck.The installer didnt leave slack on the piping for me to pull the indoor unit just to get to the flares, I will try another...
  26. Replies
    34
    Views
    1,848

    the flare connections are inside the walls, to...

    the flare connections are inside the walls, to check for leak & the customer not ready to cut walls yet, easy seal would be next option.

    Sent from my SM-G950U using Tapatalk
  27. Replies
    34
    Views
    1,848

    the flare connections are inside the walls, to...

    the flare connections are inside the walls, to check for leak & the customer not ready to cut walls yet, easy seal would be next option.

    Sent from my SM-G950U using Tapatalk
  28. Replies
    34
    Views
    1,848

    refrigerant leak sealer

    Hello techs , can any one recommend me a good refrigerant leak sealer & tools required to use the sealant tube. I never used the leak sealer before but would like to use it on a mini split unit that...
  29. [emoji106] Sent from my SM-G950U using Tapatalk

    [emoji106]

    Sent from my SM-G950U using Tapatalk
  30. if you go with 14k btu ,you would be much better...

    if you go with 14k btu ,you would be much better if sun light is your concern ,but not sure if 14k btu comes with 115volts power source in portable ac.good luck

    Sent from my SM-G950U using...
  31. Replies
    21
    Views
    1,723

    appreciate sending link, we use this type of...

    appreciate sending link, we use this type of setup every time ,never got slapped with the hose, thanks again

    Sent from my SM-G950U using Tapatalk
  32. Replies
    21
    Views
    1,723

    any idea where to purchase the adaptor for the...

    any idea where to purchase the adaptor for the co2 tank that gives you unregulated pressure, I believe the valve on the co2 is CGA320.

    Sent from my SM-G950U using Tapatalk
  33. Replies
    21
    Views
    1,723

    we stock 2 full tanks c02 in truck ,lasts a wail...

    we stock 2 full tanks c02 in truck ,lasts a wail ,hatingman can you please let me know where to buy adaptor for the co2 tank that gives you unregulated pressure,I have searched online not getting any...
  34. Replies
    21
    Views
    1,723

    I decided to go with c02 tank to blowout...

    I decided to go with c02 tank to blowout condensor coils due to more pressure, I did lookup the adaptor I would need to avoid using a regulator on my c01l2 tank, similar to the nitrogen tank I was...
  35. Replies
    21
    Views
    1,723

    the links you sent helped ,appreciate that ...

    the links you sent helped ,appreciate that

    Sent from my SM-G950U using Tapatalk
  36. Replies
    21
    Views
    1,723

    different regulator will do, thanks buddy Sent...

    different regulator will do, thanks buddy

    Sent from my SM-G950U using Tapatalk
  37. Replies
    21
    Views
    1,723

    I have exact hose set up,just need a regulator...

    I have exact hose set up,just need a regulator that gives me more pressure, thanks for reading my post

    Sent from my SM-G950U using Tapatalk
  38. Replies
    21
    Views
    1,723

    thank you for sharing your info,i will probably...

    thank you for sharing your info,i will probably get a different regulator

    Sent from my SM-G950U using Tapatalk
  39. Replies
    21
    Views
    1,723

    looking nitrogen adaptor

    hello techs am looking for a nitrogen adaptor that connects from nitrogen tank to a 1/4 refrigeration hose ,no regulator in between ,to blowout condensor coils ,the regulator that I have for my nitro...
  40. Replies
    7
    Views
    1,272

    I will just stay with my static pressure tips &...

    I will just stay with my static pressure tips & 510i ,to keep things simple, I just wanted to educate my self on these instruments ,I will raraly use my 510i ,but thanks for getting back & the info.
  41. Replies
    7
    Views
    1,272

    that's great thanks

    that's great thanks
  42. Replies
    7
    Views
    1,272

    thanks for getting back with the link &...

    thanks for getting back with the link & information, would you recommend the testo 405i over the 510i for measuring cfm & velocity pressure ? for residential & commercial use ?
  43. Thread: Smart probes?

    by nytech28
    Replies
    19
    Views
    2,412

    sorry ,I accidentally posted on the wrong post.i ...

    sorry ,I accidentally posted on the wrong post.i ment for new thread
  44. Replies
    7
    Views
    1,272

    testo 510i monometer

    Happy new year to all the techs,I recently got the testo 510i monometer that reads gas pressure,air velocity & cfm. They sell separate static pressure probes that only measures static pressure &...
  45. Thread: Smart probes?

    by nytech28
    Replies
    19
    Views
    2,412

    happy new year to all the techs,I recently got...

    happy new year to all the techs,I recently got the testo 510i monometer that reads gas pressure,air velocity & cfm. They sell separate static pressure probes that only measures static pressure &...
  46. Replies
    13
    Views
    1,092

    was under charged had to top with some 134A,...

    was under charged had to top with some 134A, works fine.
  47. Replies
    13
    Views
    1,092

    pecmsg,update no call back its ben more then weak...

    pecmsg,update no call back its ben more then weak since I charged the units,its working fine.
  48. Replies
    13
    Views
    1,092

    I did that job more then weak ago once I got my...

    I did that job more then weak ago once I got my pressures correct I stopped, & no one complained,seems like it's working good.
  49. Replies
    13
    Views
    1,092

    pecmsgam appreciate your help on other posts as...

    pecmsgam appreciate your help on other posts as well.Am not at the place know, if left that way i dont think it would cause issues cause my compressor amps was below rated.once I go back I will...
  50. Replies
    13
    Views
    1,092

    everest undercounter unit frost issue

    hello techs, checked out a (2)Everest undercounter refrigeration units after analyzing operations & manually checking DT,I charged both units to 15psi R134a, kept 20-22°SH for 1st unit but getting...