  1. Replies
    0
    Views
    758

    hill pheonix cases

    working on a glass covered OWIZ-12 , freezer island case, can you suggest where all the condensate heaters should be, around the display glass? any by the glass covers ( glass covers are an add on...
  2. Thread: Tyler

    by hem057
    Replies
    1
    Views
    1,108

    Tyler

    what compressor or capacity would have been on tyler condensing unit THS150L
  3. Replies
    7
    Views
    2,301

    I have found that adjusting cube size to make...

    I have found that adjusting cube size to make small chips and customer got many years of service form the machine
  4. Thread: true tac-48

    by hem057
    Replies
    25
    Views
    3,199

    itsiceman--- just would like to follow up about...

    itsiceman--- just would like to follow up about your comment its a timed thing??? then why put weight on the label??...so you mean they run unit 10 minutes and look for certain pressures?? we use...
  5. Thread: true tac-48

    by hem057
    Replies
    25
    Views
    3,199

    0 SUBCOOLING not 0 suction....

    0 SUBCOOLING not 0 suction....
  6. if this is an older machine and it was r-12 than...

    if this is an older machine and it was r-12 than I have had really good success with r414b.... 409 tends to have high head pressure, but this may not be a real problem to you as this water...
  7. Thread: true tac-48

    by hem057
    Replies
    25
    Views
    3,199

    just to be clear... the 400 psi was when we weigh...

    just to be clear... the 400 psi was when we weigh in the refrigerant and still had 0 subcooling, when we put in less we are around 260 psi and still have 0 subcooling....compressor always is running...
  8. Thread: true tac-48

    by hem057
    Replies
    25
    Views
    3,199

    i read on this site before a guy that worked at...

    i read on this site before a guy that worked at true and his comments about true and engineering and how at true they set up the units with weighed in charge.... that it is not weighed in at all? but...
  9. Thread: true tac-48

    by hem057
    Replies
    25
    Views
    3,199

    sorry serial number 1-4630084

    sorry serial number 1-4630084
  10. Thread: true tac-48

    by hem057
    Replies
    25
    Views
    3,199

    cap tube definitely not plugged

    cap tube definitely not plugged
  11. Thread: true tac-48

    by hem057
    Replies
    25
    Views
    3,199

    it does have the compressor and fans that were...

    it does have the compressor and fans that were installed by manufacturer, what are your thoughts about converting to txv and receiver
  12. Thread: true tac-48

    by hem057
    Replies
    25
    Views
    3,199

    true tac-48

    I'm just looking for some comments on the open 4 ft case true model tac-48, my customer just bought this unit used, we found after a month the compressor was bad.... so replaced it and
    found the...
  13. Replies
    17
    Views
    7,038

    fyi

    tried this before, changing something from hp81 to another refrigerant... didn't work, created night mare, had to eventually pull it out and go back to hp81, thought I could get away from buying a...
  14. Replies
    49
    Views
    5,149

    follow

    did you find it?
  15. Thread: taylor 490

    by hem057
    Replies
    1
    Views
    807

    anyone know the cap tube size and length

    anyone know the cap tube size and length
  16. Thread: True love

    by hem057
    Replies
    3
    Views
    1,219

    True love

    I know we all love true..... lol
    anyway... T49 FZO been looking for the leak last couple of days, should be easy to find being as we loose enough overnight to cause it to run warm, but leak...
  17. Thread: taylor 490

    by hem057
    Replies
    1
    Views
    807

    taylor 490

    working on a taylor soft serve 490, pretty simple machine, with only one compressor and AXV for the barrel, looks like cap tube to the hopper and epr on it, and board cycles the compressor every 5...
  18. Thread: keeprite RGA

    by hem057
    Replies
    1
    Views
    3,147

    keeprite RGA

    working on a small roof top unit, RGA36 Keeprite about 30? years old, found heat exchanger with holes in it, installed new heat exchanger, but having trouble with flame rolling out on the two...
  19. Thread: hussman rack

    by hem057
    Replies
    3
    Views
    1,059

    hussman rack

    working on a rack with 4 -3DB3075E compressors, removed a head today from one of the units not pumping properly, and noticed on top of the head black like residue, very slight, enough to get fingers...
  20. Thread: taylor 490

    by hem057
    Replies
    2
    Views
    781

    no sensor as per taylor

    no sensor as per taylor
  21. Thread: taylor 490

    by hem057
    Replies
    2
    Views
    781

    taylor 490

    have a taylor 490 yogurt machine, and the upper hopper will not stay cold, talked to tech support and they are telling me that it must be the board, it causes the compressor to run for a few seconds...
  22. Replies
    11
    Views
    5,244

    how did you make out with this unit, high...

    how did you make out with this unit, high pressures are out of wack for sure, is this air cooled, if you changed the drier you may have to add refrigerant to make up for the added space of a larger...
  23. have you checked condenser subcooling, this will...

    have you checked condenser subcooling, this will tell you if you have sufficient charge or not; if there is a restriction, then your discharge will be lower than what we would typically expect to...
  24. Thread: hot gas

    by hem057
    Replies
    7
    Views
    1,682

    great

    thanks for the information, useful as always ice, even though it isn't what i wanted to hear, it is useful non the less, I remember they recommend minimum of 25 - 33% defrosting while balance of...
  25. Thread: hot gas

    by hem057
    Replies
    7
    Views
    1,682

    hot gas

    customer bought a 12 foot 5 door reach in freezer, used to be in super market in a long row of cabinets, and it is hot gas defrost, now in the super market this one case would have been in defrost...
  26. Thread: wiring diagram

    by hem057
    Replies
    1
    Views
    961

    wiring diagram

    does anybody know where i can get a wiring diagram RSW 75GF general freezer
    thanks!
  27. Thread: hot gas defrost

    by hem057
    Replies
    4
    Views
    1,199

    further to that

    this is hot gas, not cool gas, there is a check valve in the hot gas jut before it t's into the liguid line just before the diffuser so that when it goes into freeze mode the line will not fill with...
  28. Thread: hot gas defrost

    by hem057
    Replies
    4
    Views
    1,199

    hot gas defrost

    have a three pipe system, last few weeks every once in a while the txv seems to stick, will work ok for days. then cusotmer comes in and cabinet is warm, line is frosted up from distributor on,...
  29. Thread: hot gas defrost

    by hem057
    Replies
    0
    Views
    726

    hot gas defrost

    have a three pipe system, last few weeks every once in a while the txv seems to stick, will work ok for days. then cusotmer comes in and cabinet is warm, line is frosted up from distributor on,...
  30. Thread: bakery

    by hem057
    Replies
    7
    Views
    1,801

    even after he puts the whole tray into a plastic...

    even after he puts the whole tray into a plastic bag?
    wonder how that can pull humdidty out of product, but maybe not freezing quickly enough? to fast?
    interesting
  31. Thread: bakery

    by hem057
    Replies
    7
    Views
    1,801

    bakery

    have a customer that has a walk in freezer, and he make these rice cakes, he puts various combos of things in the middle, freezes them and then brings out whole tray to bake, but recently he notices...
  32. Replies
    1
    Views
    2,088

    imperial convection oven

    have a convection oven at swiss chalet in ontario, looks like an Imperial, but can't find a model or serial no anywhere, need a new gas valve, the pilot is lighting fine, but the main valve has 120...
  33. Replies
    1
    Views
    1,340

    GCS lennox foot print

    where can I find the GCS3 1353 lennox footprint, need to remove this unit and replace...
  34. Replies
    18
    Views
    3,802

    still more

    this machine only has a dump valve, no overflows that are plugged, when it starts the ice making cycle it fills with water, the float sensor (eyes) see that the level of water has risen, and the...
  35. Replies
    18
    Views
    3,802

    once more

    the problem is though that I unplugged it, and since then have installed a new controller, same problem, this new controller has never had the No 7 plug installed so the new one should not be...
  36. Replies
    18
    Views
    3,802

    further to that

    thanks ice, no the water inlet valve is fine, that is what is strange about the machine and why the canadian scotsman distributor tech guy was sure it must be the board, because the float and arm are...
  37. Replies
    18
    Views
    3,802

    update

    the harvest in initiated by the water level:.
    it is not a remote condenser, it is air cooled, fan is not cycling, so the head pressure / temp is staying up; I tried a new controller, but nothing...
  38. Replies
    18
    Views
    3,802

    scottsman CME1056

    have been having an issue for 3 weeks with this machine, evap totally frozen over, hto gas ok, water inlet valve ok, when went to this machine found dump valve broken (hotel maintenance guy?) ordered...
  39. Replies
    13
    Views
    2,609

    yup

    yes yellowirenut- sure is a beauty.... amazing what some guys will do.... gotta wonder what they are thinking.... I knew it was GCS but ? thanks that helped, found it in my lennox book witha that...
  40. Replies
    13
    Views
    2,609

    will this help

    will this help
    73342
  41. Replies
    13
    Views
    2,609

    GCS16?

    GCS16?
  42. Replies
    13
    Views
    2,609

    lennox? which model

    can anyone id this lennox model no.
  43. Replies
    9
    Views
    2,579

    I usually make them (i.e. the doors) have a...

    I usually make them (i.e. the doors) have a welder friend of mine that I use to do the welding, we are pretty busy doing refrig. service work, so will only get into doing hoods/ducting for a very...
  44. Replies
    9
    Views
    2,579

    looking at captive air or westmetals both NFPA 96...

    looking at captive air or westmetals both NFPA 96 and ul approved, I think the wrap is a 3M product, do you have their product name for it
  45. Replies
    9
    Views
    2,579

    exhaust fan instll

    I am looking at installing up blast exhaust fan for new 16 foot stainless hood, renonvation, new hood will be located in other side of building, which has a floor above it, apartment, I have been...
  46. Replies
    1
    Views
    688

    chicago butcher case

    having problems with the hydrolic hinge front glass opening system on these displays with the glass not closing all the way....anyone else run into this...any suggestions
    model CH2440 s/n 030206...
  47. Thread: D5-12LU

    by hem057
    Replies
    2
    Views
    1,279

    D5-12LU

    these open coolers? capacity per foot 800?
    have D5-8Lu and D512L U to pipe up
    and 2- M3G 8
  48. Thread: hussman rack

    by hem057
    Replies
    10
    Views
    1,507

    intereting

    I would have thought the discharge sweeping through the seperator would very quickly remove the liquid refrigerant? so just the all compressors having tripped from ? causes this to happen
  49. Thread: hussman rack

    by hem057
    Replies
    10
    Views
    1,507

    no

    if you mean refrigerant migration due to cold temp, no, because even though this rack was totally down, there are two other rachs in the room and it is always warmer, warmer than outside anyway
  50. Thread: hussman rack

    by hem057
    Replies
    10
    Views
    1,507

    hussman rack

    had a late call last night, all 4 compressor on rack out on oil failure, seems like oil level in compressor high and diluted with refrig, on start up had to close suction valves to get it running,...