  1. Replies
    3
    Views
    249

    for the second part 1. (70+60)/2 = 65 2. 73 -...

    for the second part

    1. (70+60)/2 = 65
    2. 73 - 65 = 8
    3. 8 + again you said override is 65 (equal to default?) = 73

    what values can you change?
  2. Replies
    3
    Views
    249

    so based on what you said, this is what I get ...

    so based on what you said, this is what I get

    1. (72+65)/2 = 68.5
    2. 73 - 68.5 = 4.5
    3. 4.5 + I'm guessing the default is set at 68.5 (does this equal to override?) = 73 effective set point
  3. https://www.trane.com/content/dam/Trane/Commercial...

    https://www.trane.com/content/dam/Trane/Commercial/lar/Peru/Manuales/Voyager-II/RT-SVX26L-EN_IOM_Gas-Electric.pdf

    I think page 25 on this is what you are looking for
  4. Replies
    10
    Views
    385

    Thank you guys!! I appreciate the help!! ...

    Thank you guys!! I appreciate the help!!
    Unfortunately, where I work, purchasing an item from non contract vendor is harder than building a thermostat out of raw material. If T7056B is readily...
  5. Replies
    10
    Views
    385

    The main reason for the change was to use...

    The main reason for the change was to use multiple wireless sensors in a large area for averaging. I even thought about using some relays and voltage regulators for staging, but I can't find 4 stage...
  6. Replies
    10
    Views
    385

    Thanks. I already had a feeling that it was the...

    Thanks. I already had a feeling that it was the case. I will just leave as it is for now.
  7. Replies
    10
    Views
    385

    Replacing Honeywell T7067A

    I have a Honeywell T7067A connected to a Honeywell night setback panel to a Trane RTU.
    I initially wanted to replace it with a Redlink 8000, so I can average 5 wireless indoor temperature sensors...
  8. Do you have any BACNet gateway which can be...

    Do you have any BACNet gateway which can be connected to the ZR120 in question by itself? It should be connected the same way as you made the connection to the other ZR120 (I'm guessing connection to...
  9. For station to station communication, you need to...

    For station to station communication, you need to create an admin for both the supervisor station and the jace station for machine to machine communication.
    Once that's all setup, MAKE SURE TO...
  10. Thread: ALC Cable

    by mamaganoush
    Replies
    15
    Views
    899

    The part is called USB-L (purchased through ALC...

    The part is called USB-L (purchased through ALC branch)
    and the drivers are found here
    https://www.silabs.com/products/development-tools/software/usb-to-uart-bridge-vcp-drivers



    808762808763
  11. Replies
    5
    Views
    447

    On your other post, you were asking for...

    On your other post, you were asking for HyperTerminal to E-Link, and someone posted the link to a document. I was reading the document to see what E-Link was and saw the following:

    "MS/TP The...
  12. Thank you so much for the info. I will have to...

    Thank you so much for the info. I will have to replace them with something else more manageable.
  13. Johnson Control FX Programming and Backup

    I have LP-FX16X04-000C for my AC unit and LP-FXVMA11-0c for the VAVs.
    I'm trying to get them all speak to Honeywell Jace as a supervisor through Bacnet.
    What programs do I need to...
  14. Thank you everyone for the reply! I think I will...

    Thank you everyone for the reply! I think I will go with Honeywell Jaces but use mixture of JCI FX controller and Honeywell Spyders. This way I can avoid needing "Individually Licensed Controllers"...
  15. Thank you for the reply. I will look into Distech...

    Thank you for the reply. I will look into Distech as well. I'm also looking into KMC. I haven't seen KMC in action, but it looks solid.
  16. Pre-built logic/programming with minimal customizing

    Hi,

    The buildings I deal with have simple HVAC systems where I'm looking for Bacnet controllers that can be configured with pre-built logic/programming. So I can spend little time customizing the...
  17. Thanks for the input guys. Luckily, I was able...

    Thanks for the input guys.
    Luckily, I was able to recover the credential before I wipe everything and start over.
    However, I found this information and will post it here just in case someone else...
  18. I did. I didn't see one that works for Honeywell...

    I did. I didn't see one that works for Honeywell Jace 8000 unless I missed it. I just find it odd that the option is not available anywhere I could check in the serial shell
  19. Honeywell Jace 8000 platform ID/password reset through serial shell

    Hi,

    I'm trying to perform platform ID/password reset on a Honeywell Jace 8000, but I don't see an option for resetting ID and password during serial shell boot up.
    I tried to see the option when...
  20. Replies
    9
    Views
    1,256

    Yeah I saw the PDF as well, but the request link...

    Yeah I saw the PDF as well, but the request link is no longer available. If you tried to use that link, it requires sharepoint account now which makes it impossible to request if you haven't already.
  21. Replies
    9
    Views
    1,256

    I have not figured out how to log on. I missed...

    I have not figured out how to log on. I missed the time frame where I could have asked them to send the sharepoint invite through the honeywell buildings forum. I tried to sign up a new account with...
Results 1 to 21 of 21