Search:

Type: Posts; User: Snapperhead

Page 1 of 20 1 2 3 4

Search: Search took 0.21 seconds.

  1. Replies
    2
    Views
    3

    I wonder which would Win

    If I set a dehumidifier inside of a sauna ...
  2. Paint your roof white ( they have paint for...

    Paint your roof white ( they have paint for shingles ) the attic temp will drop in half , and your house will be cooler

    I have no idea who came up with BLACK roofs , but its the stupidest idea...
  3. walkin evaps are 20 deg

    walkin evaps are 20 deg
  4. Replies
    8
    Views
    207

    I've got a Slum lord has a couple 1980's units (...

    I've got a Slum lord has a couple 1980's units ( cant remember the brand ) I wanna say Carrier

    I've replaced the OD units few years ago , but the solid aluminum coils are still in nice shape and...
  5. Replies
    8
    Views
    207

    I would use that Evap WAY before I would trust...

    I would use that Evap WAY before I would trust any New Evap .... they are nothing but Garbage now

    Take a few screws out , pull out the coil , wash it with water to get the lint off , Hook it up
    ...
  6. Replies
    12
    Views
    348

    yeah the plastic is worn out

    yeah the plastic is worn out
  7. Im not sure how long R22 substitutes will be...

    Im not sure how long R22 substitutes will be around ... Well im not sure about 404 being around either , but probly longer than the 22 stuff
  8. Ha .... thats pretty neat 404 TXV for sure

    Ha .... thats pretty neat

    404 TXV for sure
  9. Replies
    3
    Views
    229

    In the past I've never found the humor in Robin ,...

    In the past I've never found the humor in Robin , but this skit is actually really amusing lol
  10. Overheating the oil will cause acid just as well...

    Overheating the oil will cause acid just as well (sometimes)

    If the outdoor fan motor quits and the customer lets it run for days like this the compressor gets hot as hell , or if the capacitor...
  11. Between all of the contactors , relays ,...

    Between all of the contactors , relays , solenoids , motors , pumps , heck it might even have an inverter , I could definitely understand the AC unit producing electrical noise

    Now what ..

    I...
  12. Replies
    10
    Views
    300

    Probly had window Ac;s

    Probly had window Ac;s
  13. Replies
    12
    Views
    348

    Yeah shes uhh ....a real pretty one aint she

    Yeah shes uhh ....a real pretty one aint she
  14. Thread: Hello

    by Snapperhead
    Replies
    20
    Views
    486

    Are you talking about Prev Maint , or Diagnosing...

    Are you talking about Prev Maint , or Diagnosing ?

    I Would rather go diag a unit then install a new system
  15. Replies
    9
    Views
    329

    Delay on Break is used on safeties Like if...

    Delay on Break is used on safeties

    Like if the unit is running along just fine and the HPS kicks out for a second , the Delay on Break wont allow it to short cycle
  16. Replies
    12
    Views
    348

    Hmm .... never been to that site before

    Hmm .... never been to that site before
  17. Replies
    12
    Views
    348

    Name this hinge

    No name on box anywhere and I need top hinge
  18. Replies
    8
    Views
    621

    yeah but the advantage to this is .... they will...

    yeah but the advantage to this is .... they will say FIX IT no matter the price

    10 million ? No problem , can I make payments ? its hot in here !
  19. Replies
    59
    Views
    1,201

    I normally only hear this from the people who are...

    I normally only hear this from the people who are smoking the weed .... I assume you are guilty :grin2:
  20. Replies
    12
    Views
    251

    I effin hate stupid calls

    I effin hate stupid calls
  21. Replies
    2
    Views
    261

    You might try taking it back and say .... it just...

    You might try taking it back and say .... it just broke off

    I've done alot of ghetto rigging , but I cannot think of a safe way to puncture that jug

    Unless you can cut a slice in the plastic...
  22. Replies
    12
    Views
    251

    How do you have the drain sensor wired in ?

    How do you have the drain sensor wired in ?
  23. Pfft ... I wouldnt pay a dime if it were legal ...

    Pfft ... I wouldnt pay a dime if it were legal

    Do a good job and you wont have to worry about it

    I can only think of 2 times I messed up and went back without charging them , and one of those...
  24. WooHooooo ! Im not the only one !!

    WooHooooo ! Im not the only one !!
  25. Replies
    12
    Views
    720

    Years ago I would tape the K type onto the line ,...

    Years ago I would tape the K type onto the line , then ghetto rig insulation around it

    But then I purchased a Cooper , and life is so much easier , and probly most accurate
  26. yup , and dont kneel down unless you brought up...

    yup , and dont kneel down unless you brought up cardboard or a rag , that rubs off
  27. Thats one helluva suction line , and cabinet is groovy

    So ....yeah....

    Chinese Restaurant , but you probly knew that
  28. Replies
    7
    Views
    460

    well then you better start buying some now and...

    well then you better start buying some now and hide in the garage ...
  29. where the water drains down from the drip tube...

    where the water drains down from the drip tube ... towards thickness probe .. make sure its clean there on that small area above the sensor

    Sometimes the water will drain weird and splash the...
  30. So yesterday I walk up to this carrier R22 unit ,...

    So yesterday I walk up to this carrier R22 unit , twist the cap off and I hear a slight but steady hiss.... Im like ... theres no way .... Put my finger over the shrader and hiss stops. Put gauge on...
  31. Replies
    10
    Views
    474

    Are we talking a Restaurant AC ... or a House

    Are we talking a Restaurant AC ... or a House
  32. The TRUTH will be covered up ... period .... end...

    The TRUTH will be covered up ... period .... end of story
  33. Replies
    6
    Views
    290

    Accounting for hose charge is purely guessing on...

    Accounting for hose charge is purely guessing on small units

    I have 3 ft long hoses

    I pull vac with both hoses

    Remove Red hose

    Open Freon tank , bleed the yellow , then hit the Tare
  34. I've not seen many on HVAC units , but Walk-in...

    I've not seen many on HVAC units , but Walk-in coolers and Freezers the shrader will leak right at the Evap for some reason
  35. Did that 1.5 lbs solve the swinging pressures...

    Did that 1.5 lbs solve the swinging pressures from 60 - 70 ?
  36. Replies
    10
    Views
    587

    You know what ..... Grainnger has it labeled...

    You know what ..... Grainnger has it labeled wrong ! Thats a "Blower" motor in the link provided , so yes that motor should work in Post # 1 coreyaustin provided
  37. Replies
    10
    Views
    587

    It sounds crazy but I've come across a couple Air...

    It sounds crazy but I've come across a couple Air Handlers with Condenser Motors swapped into them

    It must have been a weekend emergency

    But they actually lasted a long time ....

    So...
  38. Replies
    24
    Views
    615

    Yeah I would fork both wires .... before the...

    Yeah I would fork both wires .... before the other one melts

    P.S. post # 10 is not an example of forked wires , however the wires are pretty secure the way its done there
  39. Replies
    24
    Views
    615

    Yeah man , works perfect when you make a fork ...

    Yeah man , works perfect when you make a fork

    The Picture in post # 1 leaves you 2 choices , either re-do the crimp terminal , or just cut both wires out of the contactor , bypass it , and Wire...
  40. Im gonna say you either have a Drier going bad ,...

    Im gonna say you either have a Drier going bad , or a TXV going bad

    First thing I would do is .... look at that Evap coil to be sure its clean
  41. Probly run another vent , and another return

    Probly run another vent , and another return
  42. I left 2 hood fans off a couple months ago ........

    I left 2 hood fans off a couple months ago ..... luckily the manager wasnt afraid to climb up there himself when they opened
  43. Replies
    101
    Views
    2,371

    Well .... when you get calls for Resi ,...

    Well .... when you get calls for Resi , Commercial , and Refrigeration , you carry a crap pile of caps and some Relays
  44. Replies
    101
    Views
    2,371

    Im finding that whenever I build my own cap using...

    Im finding that whenever I build my own cap using a couple of them in parallel , they last for a very long time

    I also give the Fan its own cap , so 3 caps are being used
  45. Why do some places require a trap on a positive...

    Why do some places require a trap on a positive drain ??
  46. It all begins with Airflow , without proper...

    It all begins with Airflow , without proper airflow you are fighting a uphill battle

    If the airflow was terrible when they fired up the system ... and made refrigerant adjustments based on bad...
  47. So you got a couple guys on the side Well ,...

    So you got a couple guys on the side

    Well , often times the "side jobs" end up costing you the same amount as a Company would have charged.... And .... the job would have been done right because...
  48. After several 12 - 16 hr days ..... that 1 hour...

    After several 12 - 16 hr days ..... that 1 hour on my sunday off was annoying

    Then I had this Pakistani Client call me up "hey I have a wedding im doing at 12 today and need to convert my Pot...
  49. Ahem ( clearing throat ) "my son left a tool up...

    Ahem ( clearing throat ) "my son left a tool up there"

    Nobody was there that early , so it was easy to slip in and out ..
  50. The unit was on :gah:

    The unit was on

    :gah:
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4