  1. Well, if the leaks in the indoor coil it'll have...

    Well, if the leaks in the indoor coil it'll have a much faster leak rate in heat mode vs cooling due to the higher refrigerant Indoor pressures. Prepare to pay for another top off soon or get it...
  2. Thread: Ac freezing

    by KB Cool
    Replies
    7
    Views
    410

    When's the last time you replaced your filter or...

    When's the last time you replaced your filter or did you switch to filtrete right before the repairman arrived? :grin2:
  3. Thread: Cap question

    by KB Cool
    Replies
    32
    Views
    1,795

    He probably used 370v 5 mfd/ Instead of a 440v 5...

    He probably used 370v 5 mfd/ Instead of a 440v 5 mfd and it failed.
  4. Replies
    69
    Views
    2,775

    Yes, correct! And you can find out how much heat...

    Yes, correct! And you can find out how much heat the suction line is picking up in the attic, Just by taking a line temp in both locations and comparing the difference.
    If it's much cooler (50-55)...
  5. Replies
    69
    Views
    2,775

    No, with 20 degrees of SC? Definitely not low on...

    No, with 20 degrees of SC? Definitely not low on refrigerant. I'm thinking the Txv valve or strainer is gunked up from not following proper brazing procedures.
  6. Replies
    69
    Views
    2,775

    Suction line is a little warm and by the looks of...

    Suction line is a little warm and by the looks of the braze job in your first pic. We all probably know why!
  7. Replies
    69
    Views
    2,775

    It's extremely dry there. So that line should...

    It's extremely dry there. So that line should definetly "not" be sweating with a dew point of only 21. So scratch that idea that I thought might be used to help determine the actual temperature of...
  8. Replies
    69
    Views
    2,775

    Well, is the big pipe cold? What is your current...

    Well, is the big pipe cold? What is your current dew point at your location?
  9. Replies
    69
    Views
    2,775

    Do we know the Superheat?

    Do we know the Superheat?
  10. Replies
    19
    Views
    923

    That schematic doesn't make sense. Is it a...

    That schematic doesn't make sense. Is it a Chinese system?
  11. Replies
    31
    Views
    1,783

    ::DD:

    ::DD:
  12. Replies
    25
    Views
    1,764

    No. you just screw it (little tank) into an...

    No. you just screw it (little tank) into an adapter on the big tank and fill it up. The pressures in the 2 tanks will equalize. I usually get all my welds done and have, left over for a 150lb...
  13. Replies
    25
    Views
    1,764

    I just use a little revac tank. I leave the 50 cu...

    I just use a little revac tank. I leave the 50 cu nitrogen in the van and refill the little tank for purges and condensates as needed. Beats lugging the heavy tank to rooftops.

    ...
  14. Replies
    52
    Views
    2,801

    Yrs ago I had a big carrier lose it insulation...

    Yrs ago I had a big carrier lose it insulation from one of the supply trunks and I found it caught in some turning vanes blocking air flow. That unit was freezing up also. :grin2:
  15. Replies
    52
    Views
    2,801

    This guy needs to see whats up with his airflow....

    This guy needs to see whats up with his airflow. He may even have a fire damper shut. If he doesn't he can add on.
  16. Replies
    39
    Views
    1,461

    Or this....

    Or this. http://www.hvacrinfo.com/cope_ae_bulletins/cope_grnslm.pdf
  17. Replies
    39
    Views
    1,461

    In that case it could have been dye when they...

    In that case it could have been dye when they blew out the lineset.
  18. Replies
    39
    Views
    1,461

    Well, I use the blue personally. But, I have run...

    Well, I use the blue personally. But, I have run across the green stuff. Anyways, I'm confused. Is that what is under your unit now? Or is the pic from the date it was installed or from a time when...
  19. Replies
    39
    Views
    1,461

    Maybe it was soap bubbles.

    Maybe it was soap bubbles.
  20. Replies
    16
    Views
    412

    What are you going to use for heat?

    What are you going to use for heat?
  21. Replies
    37
    Views
    1,455

    Sounds like a fractional HP system with what? A...

    Sounds like a fractional HP system with what? A 6oz charge? And the guy put 4 oz of sealer in it? :D
  22. Replies
    37
    Views
    1,455

    You should have just told the guy to recover the...

    You should have just told the guy to recover the remaining refrigerant down to almost zero and then scale in new refrigerant and had him walk away. Instead you let him ruin your system. :eek: You...
  23. Replies
    37
    Views
    1,455

    IDK how your going to pull a good vacuum with a...

    IDK how your going to pull a good vacuum with a leak. You need to fix that first. Like the first guy (you?) should have instead of adding sealer.
  24. Thread: Damaged R-22

    by KB Cool
    Replies
    38
    Views
    1,455

    If it aint a burn out it gets reused.

    If it aint a burn out it gets reused.
  25. Replies
    58
    Views
    7,778

    Where does it say a residential furnace in a...

    Where does it say a residential furnace in a mobile home is illegal? My Boss thinks it's ok if the required combustion air and venting is provided. I questioned him twice. But, he stuck by his answer.
  26. Replies
    45
    Views
    1,920

    I don't see what the big deal is on why they...

    I don't see what the big deal is on why they won't move the furnace back and slip a transition in there. We had a guy complain about a new package unit we put on his flat foam roof. Said, it was...
  27. Replies
    45
    Views
    1,920

    Yes, but I would expect to see low SH. Maybe a...

    Yes, but I would expect to see low SH. Maybe a normal pressure. But, something would have to be off. I don't think it would be running text book. :grin2:
    It may even be hunting.
  28. Replies
    45
    Views
    1,920

    Have them get you a superheat and subcool reading...

    Have them get you a superheat and subcool reading including pressures. Curious to know how it's running without the coil to furnace transition, And yes, the sensing bulb looks better but still looks...
  29. Replies
    58
    Views
    7,778

    Yes that is a Mobile Home (doublewide). There is...

    Yes that is a Mobile Home (doublewide). There is a cut out in the floor for combustion air. But, i never went back. We gave her a proposal to rip it all out. Redo floor and new proper cased coil and...
  30. Replies
    45
    Views
    1,920

    Did anybody else see the TXV sensing bulb? :eek:

    Did anybody else see the TXV sensing bulb? :eek:
  31. So, you have a 2.5 ton A/H that according to them...

    So, you have a 2.5 ton A/H that according to them will move 5 tons of air? I don't think so. Maybe he cooked your TXV sensing bulb during install.
  32. Replies
    5
    Views
    359

    Are you in 2nd stage?

    Are you in 2nd stage?
  33. Replies
    23
    Views
    17,538

    That must be hot moist air seeping through your...

    That must be hot moist air seeping through your wall penetration w/a dew point higher than the temperature of your house.
  34. Thread: Mobile home

    by KB Cool
    Replies
    4
    Views
    522

    You should disable her unit for a few days. Tell...

    You should disable her unit for a few days. Tell her it broke and you have to order the part. Make her sweat her @ss off in a hot trailer for a few days.:grin2:
  35. Replies
    58
    Views
    7,778

    Seller told her it had a brand new furnace and...

    Seller told her it had a brand new furnace and not to worry. Water heater just about ready to fall through the rotted out floor. Gonna go back Saturday and yank the heater and put it on a fresh...
  36. Replies
    58
    Views
    7,778

    Found this Mutt the other day. Had so much leak...

    Found this Mutt the other day. Had so much leak sealer in it. I almost puked. And my gauges still stunk this morning. Poor lady just bought the place and wanted a "check up".
  37. Replies
    21
    Views
    1,598

    Compressors probably drinking liquid refrigerant...

    Compressors probably drinking liquid refrigerant if his LL is really that cold. Suctions too high for a restriction at the condenser and the lower ambients. What's the discharge temperature? That...
  38. Replies
    8
    Views
    410

    Car may not even be worth doing all that....

    Car may not even be worth doing all that. Especially, if he can't do it himself. Bob in PA, what's the blue book value on a 2001 Volvo? :grin2:
  39. Replies
    8
    Views
    410

    When in doubt weigh it out. There should be a...

    When in doubt weigh it out. There should be a little sticker under the hood that tells how much should be in it.
  40. Replies
    5
    Views
    635

    Here you go. I found the blue SP one to be more...

    Here you go. I found the blue SP one to be more durable.


    ...
  41. Replies
    6
    Views
    363

    https://www.youtube.com/watch?v=LR6sEEnhbL4

    https://www.youtube.com/watch?v=LR6sEEnhbL4
  42. Replies
    6
    Views
    363

    Sounds normal to me.

    Sounds normal to me.
  43. Replies
    5
    Views
    564

    I seen a couple go up in flames. Both were caused...

    I seen a couple go up in flames. Both were caused by high voltage getting into the low voltage side. You need to get a good tech. Who isn't afraid of some burnt wires and can wire your unit from...
  44. Replies
    24
    Views
    1,628

    Oh, so if your a full paying customer you get a...

    Oh, so if your a full paying customer you get a strap included with your capacitor?:grin2:
  45. Replies
    24
    Views
    1,628

    The first call of the day was for a guy who also...

    The first call of the day was for a guy who also had a home warranty. They couldn't get to his house until Friday. So, he called us. He's also going to dump his home warranty. After they botched his...
  46. Replies
    24
    Views
    1,628

    Yeah, I tested compressor cap (good), replaced...

    Yeah, I tested compressor cap (good), replaced contactor and also sold him a OFM cap (weak) and strapped it all up and then talked them into dumping the home warranty due to shoddy workmanship. I...
  47. Replies
    24
    Views
    1,628

    Typical Home warranty contractor's work.

    Typical Home warranty contractor's work.
  48. Sounds like you'll be fine. R22 uses a slightly...

    Sounds like you'll be fine. R22 uses a slightly larger piston. You don't want your coil saturation temperature to be any higher than it needs to be as it won't dehumidify as well.
  49. Why, not change it first. As you already know...

    Why, not change it first. As you already know it's just a Chatleff fitting screwed onto a distributor. A crescent wrench or 2 and 5 minutes time. Your done! Plus, you don't have any moisture...
  50. Yet, your asking questions that any trade school...