Search:

Type: Posts; User: sheedyhvac

Search: Search took 0.01 seconds.

  1. Replies
    7
    Views
    894

    As for the co2 powered lifts a friend told me...

    As for the co2 powered lifts a friend told me that theirs would suddenly drop a bit and it was sketchy. That made me not even want to consider getting one. Maybe theirs wasnt well taken care of...
  2. Replies
    7
    Views
    894

    Small material lifts

    I currently have a summner 2210 and my buddy got one too.

    We've had problems with them getting bound up while lifting and lowering if the load isn't perfectly balanced. Even then we still have...
  3. Replies
    9
    Views
    1,238

    have a yellow jacket, hilmor, ebay cheapie and...

    have a yellow jacket, hilmor, ebay cheapie and the latest is the cps blackmax. Im happy with all of them. Mostly the hilmor and cps but only used the cps once.

    Dont cheap out, spend the extra for...
  4. Replies
    4
    Views
    985

    I meant different bands or manufactures.

    I meant different bands or manufactures.
  5. Replies
    4
    Views
    985

    Duct sox alternatives

    Looking for alternatives to the duct sox brand. Anyone know whos out there?
  6. Replies
    4
    Views
    441

    Thanks for breaking it down for me. Ill let you...

    Thanks for breaking it down for me. Ill let you know once I get it installed. Natural gas I'm in southern cali all the surrounding counties switched to lownox only. Some guys are switching to heat...
  7. Replies
    4
    Views
    441

    No worries I called in and they emailed me a...

    No worries I called in and they emailed me a copy. I appreciate it.

    Can you clarify the last statement. If the co is within acceptable range that its under fired? Thats confusing to me. The way im...
  8. Replies
    4
    Views
    441

    York manuals online

    Looking for an install manual for tl8e080c16uh11 .

    Never installed lownox and want to be prepared, couldnt find it online maybe im looking in the wrong place. On hold with the parts house but in...
  9. I had a commercial customer go through probably...

    I had a commercial customer go through probably 30 aprilaires. Ive put in around 60 quest units which is santa fe and ultra aire rebranded in commercial applications . These things are running 247...
  10. Replies
    8
    Views
    748

    Actually came across some new in box on offer up...

    Actually came across some new in box on offer up so maybe look there or craigslist. Maybe they still have some in mexico? Kinda a tough one. Maybe windiw units? If your located in socal I may be able...
  11. Just a long awaited update on this equipment. One...

    Just a long awaited update on this equipment. One issue was the rooms main load was electronics and when these turned off 90% of the load was gone. Issues, coil freeze etc. Ended up puting in hot gas...
  12. Replies
    1
    Views
    299

    Roofers in Inland Empire/ Riverside CA

    If this is the wrong area to post let me know.
    Looking for a roofer in Riverside CA. Any recommendations apprecieted.

    Thanks!
  13. Thread: Memphis

    by sheedyhvac
    Replies
    6
    Views
    794

    Memphis

    I have some questions for any teches that live in Memphis tn. Im relocating there within a year, i do light commercial/residential in California,and i bought a house out there. Id like to hear...
  14. I'm afraid that if I add more gas Ill have way...

    I'm afraid that if I add more gas Ill have way too much subcooling and over charge. not sure what to do here.
  15. Low head/suction psi normal SC/SH normal TD

    Company ditched an install when having start up issues, were trying to clean it up. daikin 10 ton split. There is a load in the space.

    Evap- 100psig(32) 12.5 SH at the condenser.

    Cond-...
  16. Replies
    5
    Views
    2,256

    Thermastor SD-12 Dehu round 2!

    So I posted a thread about the condenser portion of a split system dehumidifier that I recieved from thermastor. The compressor was not piped into the condensing coil and there were no service valves...
  17. Replies
    9
    Views
    3,287

    Complete garbage, I will never deal with them...

    Complete garbage, I will never deal with them again. THEY SENT ME ANOTHER WITH THE SAME PROBLEM! UNBELIEVABLE!!!!!

    The shipping company told me theyd be here between 11am-5pm so i told them to...
  18. Replies
    9
    Views
    3,287

    FROM THE FACTORY! SD-12 Dehu

    I looked through the install manual a few times but I just can't seem to find the section on piping up the condenser. The insulation is supposed to be peeling back right?
  19. I know that this probably sounds stupid. But I've...

    I know that this probably sounds stupid. But I've never build a curb. Don't know what a doghouse is either. The only experience I have is working with my father and he mainly services large chillers...
  20. How do I seal through the roof duct penetrations ??

    Just wanting to know the proper methods. I've looked through my ahri fundementals book and all over the internet but couldn't find a good guide. should I just trust roofers?
  21. Replies
    16
    Views
    2,644

    I love specifics. Thanks. Reading through...

    I love specifics. Thanks. Reading through fundementals of psychometrics and airflow right now, already know im gonna haveto read it two more times though!
  22. Replies
    16
    Views
    2,644

    Good to know. Looks like I need to learn about...

    Good to know. Looks like I need to learn about coil dew points and things like that. Hopefully its covered in the air properties class i start tonight. Do you happen to know if there are coils that...
  23. Replies
    84
    Views
    11,181

    Seriously appreciate the explanation, hope I get...

    Seriously appreciate the explanation, hope I get the change to apply it some day.
  24. Appreciate the insight. About the york condensers...

    Appreciate the insight. About the york condensers whats your opinion on the micro channel coils? I've installed one but have heard comments from people saying that micro channel isn't as good for...
  25. Replies
    84
    Views
    11,181

    I saw someone mention a dual riser, I'm going to...

    I saw someone mention a dual riser, I'm going to read up on that. Id like some more info/solutions to this if you don't mind. I've seen oil traps called for in manuals, never read to deep into it...
  26. Goodmans reputation. Is their equipment that bad? Why?

    A lot of people I've met bash Goodman equipment.
    I've personally only installed ICP equipment and two goodmans. The two things I didn't like on the equipment I installed were the thinner gauge air...
  27. Replies
    16
    Views
    2,644

    Blower speed and sensible/latent heat.

    I'm still learning so go easy on me. If I have a 60,000btu system I know that some cooling will be sensible and some latent. If I slow the blower down to lets say 300-350 cfm I know I will lose...
  28. Replies
    15
    Views
    4,915

    Haha noo way is this my house. It's a house being...

    Haha noo way is this my house. It's a house being rented by a family member. I did a report on it for a gas heating class I'm taking. I'm hoping the owner will be willing to have me clean it up....
  29. Replies
    15
    Views
    4,915

    Another goodman...

    No explanation needed.

    631391631381631371631361631351
  30. Trane condenser with goodman air handler. Do i still weigh in charge?

    So I have a 5ton 13 seer trane condenser and a 13 seer goodman air handler, field installed tev. I'm assuming that I should just weigh in the charge for the additional line set + LL filter drier.
    ...
  31. Replies
    21
    Views
    7,507

    Forgot my liquid tight.

    Pretty self explanatory.

    582771582781582791
  32. Mini split install on a beach front home. Corrosion prevention?

    Just started my search, pretty sure I'll find what I need but figured it can't hurt to ask for some guidance. I'm leaning toward getting a cheap unit and finding a coating to put on myself. I'm also...
  33. Definitely considering it.

    Definitely considering it.
  34. Looking for a 3ph 5 ton condenser with a variable speed compressor.

    Called a few parts houses but no luck so far. Any suggestions? thanks guys!
  35. I have the Turbo Torch and I like it. What I...

    I have the Turbo Torch and I like it. What I usually do is barely crack it until I can feel the nitrogen blowing in the palm of my hand, hook it up, and get to work.
Results 1 to 35 of 39