  1. Replies
    7
    Views
    256

    Probably covered in lint now.

    Probably covered in lint now.
  2. Replies
    6
    Views
    195

    Maybe in lockout and ur just resetting it?

    Maybe in lockout and ur just resetting it?
  3. Replies
    6
    Views
    185

    As said above,verify temp in and out over the...

    As said above,verify temp in and out over the indoor coil and also the return temp at the return grills and then at the return of the coil. Are you sure the outdoor unit is running and producing heat...
  4. Replies
    17
    Views
    353

    The Stay Brite specs tell the tale. Never leave...

    The Stay Brite specs tell the tale. Never leave home without it.
  5. Wait till the heat exchanger fails, as they will...

    Wait till the heat exchanger fails, as they will in that date range, put your money into a new furnace. There is plenty of reading on carriers older 90 s lawsuits.
  6. Replies
    19
    Views
    646

    Verify gas quality and pressure first, pilots...

    Verify gas quality and pressure first, pilots cleaned, i guess you could just have worn out valves but i would start at the beginning points first. At least new valves or at least one would be handy...
  7. Replies
    10
    Views
    326

    So the white wire is shorted somewhere? i would...

    So the white wire is shorted somewhere? i would pull up a chair and run it thru all cycles a couple times.
  8. Replies
    74
    Views
    1,551

    Bring in all the rats that know what happened,...

    Bring in all the rats that know what happened, the ones hiding behind absolute immunity if you want to get pass here say, Doubt they will tell the truth, but i think they know the story.
  9. That old of air handler should be replaced, but...

    That old of air handler should be replaced, but it should be easy to trouble shoot. Leave one lead on xfmr common and use the other to follow the circuit around.
  10. Replies
    7
    Views
    262

    Is that a danfoss valve brazed onto the dist body...

    Is that a danfoss valve brazed onto the dist body and the real skinny cap tube line to bulb?
  11. Thread: Rheem hm2417ja

    by buford
    Replies
    5
    Views
    227

    Start asking friends or neighbors for...

    Start asking friends or neighbors for recommendations on hvac co. Your power provider may have a list of approved contractors.
  12. Thread: Rudd fan issue

    by buford
    Replies
    2
    Views
    189

    Get a meter on it.

    Get a meter on it.
  13. Replies
    7
    Views
    313

    Hopefully someone balanced them when they were...

    Hopefully someone balanced them when they were installed, if no verification, that would be a good place to start along with having the econos checked.
  14. Replies
    8
    Views
    416

    Well if you look at the first pic you will see...

    Well if you look at the first pic you will see oil stain on the end of the copper, on the end of support leg and on the ground all in the vicinity of the discharge pipe. That is where i would start...
  15. Replies
    46
    Views
    1,182

    Was it air balanced or proof of correct amount of...

    Was it air balanced or proof of correct amount of airflow.
  16. Replies
    18
    Views
    695

    Is there a cap on the bottom of the tee?

    Is there a cap on the bottom of the tee?
  17. Replies
    13
    Views
    663

    Checked gas pressure thru all operations?

    Checked gas pressure thru all operations?
  18. Get a HW vision pro, it will be able to be used...

    Get a HW vision pro, it will be able to be used on any upgrade of the system in the future.
  19. Replies
    8
    Views
    416

    Does have oil staining on the piping end and...

    Does have oil staining on the piping end and under it. Get the electronic sniffer out.
  20. Replies
    46
    Views
    1,182

    Is the econ min position set to be open too much...

    Is the econ min position set to be open too much possibly. Sounds like maybe all programming needs to be gone thru.
  21. Replies
    46
    Views
    1,182

    Does it have fire dampers that could have shut...

    Does it have fire dampers that could have shut down ?
  22. The reason i asked is i just put in a model...

    The reason i asked is i just put in a model CH16b24 that the inverter driven comp has a ringing sound when it gets up to full speed. I just have not checked out what it is yet
  23. Inverter type odu?

    Inverter type odu?
  24. Agree above, but i would of thought even at that...

    Agree above, but i would of thought even at that pressure for those days something should show up. Hopefully a new drier and nitrogen flush while brazing was done. Did you see this work being done?
  25. Replies
    3
    Views
    220

    It was used when you did not have enough wires...

    It was used when you did not have enough wires when you add AC and needed the extra wire for cooling. Find a older tech who knows how to fish wiring and run new wire to stat, 18/10 for all your...
  26. Your tech needs to look a little harder. And...

    Your tech needs to look a little harder. And there is a lot of ways to find leaks beyond checks the coil and electronic tests.
  27. Replies
    41
    Views
    1,180

    Sounds like Tranes inducers that ran like that,...

    Sounds like Tranes inducers that ran like that, on the older Voyagers.
  28. Replies
    20
    Views
    729

    I would also add to verify heat exchanger is...

    I would also add to verify heat exchanger is good, gas pressure check as said above, and put a amp clamp on the HSI while energized, you can have a small crack that will get warm but not ignite. If...
  29. Replies
    7
    Views
    403

    Cow bells.

    Cow bells.
  30. Replies
    9
    Views
    266

    Its a 240 volt motor so you will have 120 to each...

    Its a 240 volt motor so you will have 120 to each wire. Not a DIY site.
  31. Replies
    29
    Views
    7,941

    Correct setpoints and verify readings from...

    Correct setpoints and verify readings from sensors, proper maint and owner training.
  32. Thread: Fun

    by buford
    Replies
    13
    Views
    940

    Great work!

    Great work!
  33. Replies
    3
    Views
    222

    And have them put the model numbers of proposed...

    And have them put the model numbers of proposed equip on the quote to verify what you are going to get and that its a match for efficiency ratings.
  34. Thread: Limit switch?

    by buford
    Replies
    6
    Views
    355

    And what does your multimeter tell you?

    And what does your multimeter tell you?
  35. Replies
    14
    Views
    500

    Her husband is a real class act, while the fun...

    Her husband is a real class act, while the fun was going on he was no problem, then when kicked to the curb he is butt hurt. Granted, if you have nude pics out there they should be more secure, but...
  36. Replies
    1
    Views
    163

    Do not hear much on the payoffs to the girls,...

    Do not hear much on the payoffs to the girls, cohen , even the kids and other family members are laying low. Congress needs to grow a set and realize he is not King or the Don of this country.
  37. Replies
    3
    Views
    228

    Use the OEM motor , plenty of places to buy it.

    Use the OEM motor , plenty of places to buy it.
  38. Replies
    15
    Views
    519

    What about a electronic air cleaner, have one of...

    What about a electronic air cleaner, have one of those or a crawl space with unsealed ducts? And where is the condensate drain draining at.
  39. Replies
    15
    Views
    519

    Have you got a quality CO alarm inside. From my...

    Have you got a quality CO alarm inside. From my chair sounds like a CO leak.
  40. No the oem rating switch should be used.

    No the oem rating switch should be used.
  41. Replies
    7
    Views
    356

    If you have a outdoor sensor for the t stat ,...

    If you have a outdoor sensor for the t stat , there should be a option set up for the balance point. The propane back up should come on in defrost though above this setting as needed.
  42. Replies
    7
    Views
    356

    Just above the balance point.

    Just above the balance point.
  43. Looks like you have some more amps you can use. I...

    Looks like you have some more amps you can use. I would verify clean blower wheels and worn pulleys and belts first , then up the blower speed using a VP type pulley and then fixed size if the...
  44. Replies
    40
    Views
    2,928

    Did i miss what the entering air temp to...

    Did i miss what the entering air temp to condenser is? and the outlet temp. Maybe a air re circulation issue coupled with high load. water clean the cond coil?
  45. Replies
    14
    Views
    731

    All else fails, some city's have noise standards...

    All else fails, some city's have noise standards that might be exceeded.
  46. Thread: Simple 80%er

    by buford
    Replies
    15
    Views
    978

    Nice to see a great looking and serviceable...

    Nice to see a great looking and serviceable install. Wish more owners of company's would get out and inspect jobs to see what installers actually do.
  47. Replies
    7
    Views
    435

    Some boards do a defrost on accumulated time even...

    Some boards do a defrost on accumulated time even though the defrost sw has not initiated it. Kinda of a fail safe defrost.
  48. Replies
    9
    Views
    262

    For the cost of new system, a second opinion may...

    For the cost of new system, a second opinion may be in order, one that specializes in boilers.
  49. Replies
    4
    Views
    411

    Need a lot more info.

    Need a lot more info.
  50. Replies
    9
    Views
    262

    Well they did not fix the no heat, i would call...

    Well they did not fix the no heat, i would call and talk to the owner, couldn't hurt, at the least take off the new controller and credit it. Still sounds like a more seasoned tech is needed.